Displaying 20 results from an estimated 1000 matches similar to: "mge-shut don't reboot ups by default"
2006 Jul 13
2
MGE Pulsar Extreme - restart problem
Hello,
looking for replacements for some older Powerware equipment I found the MGE
Pulsar Extreme 1000C and I'm currently testing one with nut-2.0.3 on a
self-brewn i386-linux.
Upto now everything seems to work fine - except I can't get the power outlets
switching on again after mains returns. As this works with Personal
Solution-Pac 2 on W2k I thought that there might be a way to
2006 Aug 12
4
Will MGE-UPS Ellipse USBS auto shutdown?
I have an Ellipse USBS connected via serial cable to a CentOS 3 box.
Do I need to turn off the UPS as the final stage of shutdown, or will
the UPS power itself off, before the battery reaches a level to low to
safely recharge from?
I notice there is the option for the UPS to turn itself off (and on
again) unattended if power is restored during shutdown, but there
doesn't seem to be an option
2010 Jan 22
1
Eaton / MGE Ellipse MAX 600 USBS and nut
Hi there,
I've replaced yesterday my old UPS with a brand new "Eaton Ellipse MAX 600
USBS".
I've choosed the Eaton (previously MGE) both because I've always been
extremely satisfied with MGE UPSes of all kinds at work, and because of the
involvement of MGE (with Arnaud) in nut development, which made me quite sure
that I would have no trouble with an Eaton (MGE) UPS and
2007 Oct 23
1
MGE Pulsar Ellipse 800 offearly or box shutdown late
I'm struggling to configuring nut for MGE Pulsar Ellipse 800 (at least
Ellipse 800) for two boxes - home firewall and file server. I'm using
Debian 4.0 Etch, every one of them.
I'm built (after some dangerouse experiments) a testing configuration,
where boxes are plugged to line, server playing as a master, firewall as a
slave, and UPS connected to an electric heater about 300 Wats (no
2007 Oct 25
12
MGE Ellipse 800 shutdown problems
Thanks for suggetions and keep me indumb about making of Debian packages:D
I will try this package "nut_2.2.0-2_i386.deb"
One little questionm, shoud I use newmge-shut driver? - my ups is quite
old - more then 3 years, connected through serial cable.
>> PS: Arjen de Korte suspected something was wrong around my "heater" load,
>> for now I have used two 150W lamps
2006 Aug 17
1
Powerdown on FreeBSD
Hi all,
I just bought a Trust 1000VA PW-4105 UPS.
I installed the UPS on FreeBSD 6.1, and installed NUT 2.0.3 via the FreeBSD
port.
I had no problems installing and configuring nut and the UPS to run with the
PowerMust driver.
My problem however is when I test the powerdown function by issuing the
command: 'upsmon -c fsd'
The UPS is cutting the power before the shutdown procedure
2010 Dec 29
2
Again me :)
Dears,
I finally resolve my problem, I just make symbolic link:
[test at box var/run/]# ln -s -T /var/state/ups/ nut
Now I finally got services online:
# /sbin/service ups start
Starting UPS driver controller: [ OK ]
Starting upsd: [ OK ]
Starting UPS monitor (master): [ OK ]
BUT, on upsc I
2005 Aug 30
0
mge-shut doesn't use lowbatt parameter
Hello nuters,
FreeBSD, Ellipse USBS 800, serial line, nut 2.02 everything works fine.
But I'm only able to get an automatic shutdown when reaching the
built-in 30% level. I the "lowbatt parameter" is set to anything,
it's simply ignored.
This is a problem as I want to shutdown around 90% to avoid the
battery to drain out when multiple shutdowns occur.
Any idea ?
2006 May 16
2
MGE Pulsar Extreme communication problems
Hi,
I am trying to talk to an MGE Pulsar Extreme UPS over RS232 with the
mge-shut driver but I'm having some problems.
It appears to init OK but I can't, say, turn the outlets off, eg..
harrow:~>upsc mge@localhost
battery.charge: 78
battery.charge.low: 20
battery.runtime: 05760
driver.name: mge-shut
driver.parameter.port: /dev/cuad1
driver.version: 2.0.3
driver.version.internal: 0.65
2018 Oct 04
2
after power outage and proper shutdown, UPS turns on before power returns
On Tue, Oct 2, 2018 at 3:59 PM Charles Lepple <clepple at gmail.com> wrote:
>
> On Sep 27, 2018, at 6:59 PM, Gabriel <jarod125 at gmail.com> wrote:
> >
> > Hi,
> >
> > I'm struggling with a peculiar issue with my UPS. After a power
> > outage, the devices powered by it properly shut down via nut.
> > Eventually, the UPS also goes down.
2013 Dec 06
2
Delayed UPS start up after shutdown?
Hello, Ren?.
> You can change the parameter
> ups.delay.start into your UPS to set the "Interval to wait before
> (re)starting the load (seconds)"
>
> use upsset to change the value.
So far, the ups.delay.start parameter in my MGE Protection Center 675
has always been equal to the driver.parameter.ondelay parameter (which
equals the ondelay argument in ups.conf).
2006 Jun 27
3
Setting MGE powershare attributes
Hi!
We have two MGE Evolution 1100 here, and I want to make use of the
powershare outlets to force a particular boot sequence on the machines
powered by them. However I'm not sure how to set those variables upon
NUT starting, without having to change the init scripts to call
"upsrw".
Is there some place where I can set them, where they can be read
automatically on startup?
One of
2018 Sep 27
2
after power outage and proper shutdown, UPS turns on before power returns
Hi,
I'm struggling with a peculiar issue with my UPS. After a power
outage, the devices powered by it properly shut down via nut.
Eventually, the UPS also goes down. Power is still out, however,
roughly 40 seconds after the UPS shut down, it turns back on and it
starts supplying power to the load, thus turning back on the devices
attached to it. This is obviously not something I want. In
2019 Oct 26
3
Problems with NUT on Raspberry Pi
Hi, thanks for your reply.
>> The Unit is new, the battery drains because it went down to about 15
>> percent before NUT shuts it down.
>>
>> Yes, I can here a "clac". The problem is not the shutdown procedure,
>> it works quite good. After the Unit reaches 20 percent the NUT-Server
>> on the pi shuts down the system and the ups is turned off as
2018 Mar 02
1
Work around for power recycling after shutdown.return - TSSHARA UPS - nutdrv_qx driver - megatec protocol
2018-02-28 21:11 GMT+01:00 Jairo Rotava <jairo.rotava at gmail.com>:
> Hello,
>
> I think that on this file nutdrv_qx_megatec.c the definition for
> shutdown.stayoff may be wrong. In the file the definition is "S%sR0000\r"m
> while on the megatec protocol description (
> http://networkupstools.org/protocols/megatec.html) the command is just
> "S%s\r".
2010 Nov 11
1
Setting offdelay and ondelay in Smart-UPS 1500 RM units
Hello there.
Have been experimenting with an APC Smart-UPS 1500 RM and would like to share
the results of my research. I hope this could be of help to people having this
kind of units. I would also like to give something back to the NUT community. :)
Here are the details of the unit in question (a 1500 VA rack mountable one):
Model: Smart-UPS 1500 RM
Firmware revision: 617.3.I
USB firmware
2019 Oct 26
2
Problems with NUT on Raspberry Pi
>> [Roger wrote:]
>>> By the way, do you have offdelay and ondelay values in your ups.conf ?
>>
>> No, I haven’t. I just added. Should I add more lines here?
>>
>> maxretry = 3
>>
>> [ups]
>> driver = usbhid-ups
>> port = auto
>> desc = "CPS"
>> pollinterval = 15
>Yes, ondelay
2013 Dec 06
0
Delayed UPS start up after shutdown?
Hi,
I own one a MGE Protection Center 675. You can change the
parameter ups.delay.start into your UPS to set the "Interval to wait
before (re)starting the load (seconds)"
use upsset to change the
value.
Regards,
Ren?
Le 2013-12-06 15:14, Angel Tsankov a ?crit :
> Hello.
>
> I am faced with a configuration where the OS (Debian
6.0.8) and the PC
> shut down before
2013 Dec 06
3
Delayed UPS start up after shutdown?
Hello.
I am faced with a configuration where the OS (Debian 6.0.8) and the PC
shut down before the UPS (MGE Protection Center 675). Also, the UPS
restores power to attached devices as soon as main power is back but the
PC does not detect power restorations that occur less than a couple of
seconds, say 10, after its power supply has been cut. As a result, if
main power comes back within 10
2019 Apr 10
2
ondelay parameter does not work with NUT on Raspbian and Eaton 5E850iUSBDIN UPS
Thanks for help!
Are you happy with your Eaton Elipse ECO 1600?
Does it work well with ondelay?
I will need some UPS that supports the ondelay parameter.
Bartosz
śr., 10 kwi 2019 o 13:06 Roger Price <roger at rogerprice.org> napisał(a):
> On Wed, 10 Apr 2019, Bartosz wrote:
>
> > I don't see ups.delay.start anywhere. Here is the output of upsrw:
> >
> > upsrw