similar to: Outlet switching on the MGE Pulsar 1500 using usbhid-ups on FreeBSD

Displaying 20 results from an estimated 3000 matches similar to: "Outlet switching on the MGE Pulsar 1500 using usbhid-ups on FreeBSD"

2011 Oct 06
1
Differences between USB and serial on an MGE Pulsar Evolution 3000
Hi, I've been using NUT for many years to look after the UPS on my home servers. Originally I was using a Compaq R3000 but that was replaced with an MGE Pulsar Evolution 3000 about a couple of years ago because the Compaq one was just too noisy! I'm just setting up a replacement server and would like to connect it using a serial cable as I've found that the USB connection
2006 May 11
0
MGE Pulsar Extreme communication problems
Hi, I am trying to talk to an MGE Pulsar Extreme UPS over RS232 with the mge-shut driver but I'm having some problems. It appears to init OK but I can't, say, turn the outlets off, eg.. harrow:~>upsc mge@localhost battery.charge: 78 battery.charge.low: 20 battery.runtime: 05760 driver.name: mge-shut driver.parameter.port: /dev/cuad1 driver.version: 2.0.3 driver.version.internal: 0.65
2014 May 26
2
Resetting replace battery status on Pulsar 1500
Hi, I have a FreeBSD 9.2 system with NUT 2.6.5 (installed via the ports tree) with an MGE Pulsar 1500 connected. A while ago it complained it needed the battery replaced and it was finally replaced last week, however I can't find out how to reset the flag in NUT. I've looked in upsc, upsrw and upscmd but none seem to have a suitable option. The UPS is connected via RS232 and upsc output
2012 Jun 26
1
NUT MGE Pulsar Ellipse Premium 800: Changed NUT rw variables?
Hello all, I've got an MGE Pulsar Ellipse Premium 800 powering a couple of FreeBSD systems. Driver used is mge-shut, I don't know what the new mge-shut driver offers, but I follow the "if it works, don't fix it" dogma here. :) I also had a nut server installed on the master, with the /usr/local/etc/rc.d/nut script slightly modified to include a couple of upsrw commands
2008 Apr 01
1
Incorrect battery status on MGE Pulsar M 3000
Hello! We have two upses: MGE Pulsar M 3000 and MGE Pulsar EXtreme 3200C. They connect to server by USB. EXtreme works good with usbhid-ups (nut 2.2.1) and newhidups (nut 2.0.5). But Pulsar M doesn't want to work with usbhid-ups. - my ups.conf: [extreme] driver = usbhid-ups port = auto product = "EXtreme" [pulsar] driver = usbhid-ups port =
2006 May 16
2
MGE Pulsar Extreme communication problems
Hi, I am trying to talk to an MGE Pulsar Extreme UPS over RS232 with the mge-shut driver but I'm having some problems. It appears to init OK but I can't, say, turn the outlets off, eg.. harrow:~>upsc mge@localhost battery.charge: 78 battery.charge.low: 20 battery.runtime: 05760 driver.name: mge-shut driver.parameter.port: /dev/cuad1 driver.version: 2.0.3 driver.version.internal: 0.65
2007 Aug 11
1
[MGE EVOLUTION 850 VA/ ups 2.0.4] Output.voltage is at 0.0
Hello ! I've just a problem with upsd/upsmon 2.0.4, please have a look at the upsc command: -------------------- battery.charge: 59 battery.charge.low: 5 battery.runtime: 1312 battery.voltage: 24.0 driver.name: newhidups driver.parameter.port: auto driver.version: 2.0.4 driver.version.data: MGE HID 0.9 driver.version.internal: 0.28 input.frequency: 0.0 input.transfer.boost.low: 184.0
2007 Jan 09
1
Differences between newhidups (MGE tables) in 2.0.4 and svn trunk
I was looking at how other drivers deal with outlet collections, and I noticed some differences between newhidups in 2.0.4 (from Debian's 2.0.4-2.3) and the SVN trunk (rev 723) on an Evolution. Full diff is below, but here are the highlights: * MGE HID 0.9 vs 1.0 * outlet.#.switch seems to have moved to the commands outlet.#.load.{on,off} Then I found this in the ChangeLog: * fix
2007 Feb 01
2
NUT-2.0.3 - problems on setting values
Hello, we have a MGE Pulsar Evolution 800 connected to a Fedora Core5 Server using a serial cable. Installed and configured properly are RPM versions of nut-2.0.3-0.1.fc5 nut-client-2.0.3-0.1.fc5 nut-cgi-2.0.3-0.1.fc5 which all work (mostly) fine. The server is connected to outlet.0 and properly shuts down when it's loosing power after around 20 minutes. It also boots up whenever the ups
2007 Mar 12
3
upsmon keeps broadcasting on battery / on power (driver is newhidups)
Hi, I try to install the newhidups driver for a MGE Pulsar M2200 connected to a USB port under Linux Red Hat 4 Upd 4. I have compiled and installed the usb driver (make usb && make install-usb). I followed the instructions in /nut-2.0.5/scripts/hotplug-ng/README abour the /etc/udev/rules.d/025_nut-usbups.rules. The ups is recognized by the kernel: Mar 12 14:52:03 serveur1 kernel: usb
2007 Mar 12
3
upsmon keeps broadcasting on battery / on power (driver is newhidups)
Hi, I try to install the newhidups driver for a MGE Pulsar M2200 connected to a USB port under Linux Red Hat 4 Upd 4. I have compiled and installed the usb driver (make usb && make install-usb). I followed the instructions in /nut-2.0.5/scripts/hotplug-ng/README abour the /etc/udev/rules.d/025_nut-usbups.rules. The ups is recognized by the kernel: Mar 12 14:52:03 serveur1 kernel: usb
2006 Jun 09
1
MGE ellipse 1200 config and documentation
Hi, I have recently purchased MGE ellipse 1200 UPS for my home system. Obviously, the choice of this particular brand was mainly dictated by MGE's long-standing support for Linux and NUT project. The fact that the box was clearly the prettiest looking one on the block did help also ;-). I have had NUT tools installed and configured in no time, as I did it numerous times before -- kudos
2005 Aug 30
0
mge-shut doesn't use lowbatt parameter
Hello nuters, FreeBSD, Ellipse USBS 800, serial line, nut 2.02 everything works fine. But I'm only able to get an automatic shutdown when reaching the built-in 30% level. I the "lowbatt parameter" is set to anything, it's simply ignored. This is a problem as I want to shutdown around 90% to avoid the battery to drain out when multiple shutdowns occur. Any idea ?
2014 Dec 17
2
EATON 9SX not display battery.charge
OS version: FreeBSD 8.4-RELEASE-p19 NUT version: nut-2.7.2_6 NUT installation method: from freebsd pkg system Device info: EATON 9SX 5000i, manufacturing date: 05.09.2014 ups.firmware: 9SX5Ki When i try to see battery charge, in output it have not such variable, and i can't control my server and other clients connected to them. Any options cannot power of server. How to see current battery
2020 Sep 11
1
UPS recommendation for NUT and power-on-delay support
On Fri, Sep 11, 2020, at 4:05 PM, Bartosz wrote: > Dear All, > > Could you please recommend me a UPS with 100% support of the ondelay parameter and NUT compatibility? > > 850 or 1000 VA > > I have the EATON 5E850iUSBDIN UPS and it does not support this parameter so I would like to buy another UPS that for sure will support it. > > Thank you, > Bart Can you tell
2008 Dec 06
1
MGE Evolution and programmable outlets configuration
Hi, I'm a MGE Evolution 650 owner and, after putting in place a basic configuration for controlling my UPS, I'm going to tune a little bit better NUT for my needs. First of all let me describe my little (SOHO) scenario: I have the ISP modem/switch (providing VoIP too, so it's important to keep it running as much as possible), a small low power home server and a much hungrier PC.
2010 Oct 06
1
Model list missing my UPS, here is info for inclusion on the list
Hello Niels, thanks a lot for this compatibility submission. This is part of the remaining things at Eaton. I've added an entry to the new Hardware Compatibility List: http://new.networkupstools.org/stable-hcl.html BTW, have you tested a shutdown with this unit? Otherwise, you should! thanks again, Arnaud Quette Le samedi 02 octobre 2010 ? 12:42 +0200, Niels Kristian Jensen a ?crit :
2006 May 12
1
Various NUT issues/questions
Hi, FINALLY got my UPS working, YEA!!!! But now it brings up even more issues.. (BOOO!!) 1) I'm thinking this is a UPS issue, but when I pull the plug on my UPS, it goes from 100 to 30 in just a short amount of time (Minutes). This causes the machine to shut down. But once it gets to 0, its beeped its little heart out for a few more HOURS providing power to the non-system items perfectly.
2020 Sep 30
2
reset "replace battery" flag
On Fri, Sep 25, 2020 at 11:47:42PM +0300, Manuel Wolfshant wrote: > On 9/25/20 1:36 PM, Lionel Élie Mamane wrote: >> On Thu, Sep 24, 2020 at 06:51:23PM +0300, Manuel Wolfshant wrote: >>> On 9/21/20 9:47 PM, Lionel Élie Mamane wrote: >>> We have a HP R/T 3000 G4 UPS; according to the data returned by >>> the usbhid-ups driver, it seems to be a "badge
2005 Aug 19
1
MGE Ellipse 800 USBS doesn't shutdown under FreeBSD
Hi all, First of all thanks for the great work on nut ! (despite it's not fully functional yet overhere). Everything seemed to go fine until the final test : shutdown the UPS ! The system is running FreeBSD 5.3, the UPS is MGE Ellipse 800 USBS both linked with the MGE serial cable. The system is a remote server, only running some file services and large disks. The porting,