similar to: Success report: APC Back-UPS RS 800

Displaying 20 results from an estimated 2000 matches similar to: "Success report: APC Back-UPS RS 800"

2009 May 08
1
Battery test feature of APC Back-UPS RS series
Hi all, I use an APC Back-UPS RS 800, overall my experience with NUT is very good but there is one feature I am missing: the ability to ask the UPS for a battery test. upscmd -l shows the following commands available: $ upscmd -l rs800 Instant commands supported on UPS [rs800]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS
2008 Sep 24
1
APC RS-800 usb not shutdown
Hello world! Please, help me :-) I have a APC RS-800 usb and it don't shutdown. I try every things but nothing: don't shutdown. Uhmmmm My actual situation: tux:/home/effem# uname -a Linux tux 2.6.26-1-686 #1 SMP Wed Aug 20 12:56:41 UTC 2008 i686 GNU/Linux tux:/home/effem# wajig policy nut nut: Installato: 2.2.2-6 Candidato: 2.2.2-6 Tabella versione: 2.2.2-7 0 -20
2009 Jan 06
3
Strange ups.load and battery.temperature with an APC Back-UPS RS 800 (NUT v2.2.2)
Hello!! I have a APC Back-UPS RS 800 and I'm using NUT v2.2.2 on a PowerPC powered NAS. With WinNut, I found the ups.load value strange, so I've done a "upsc ups" and got this results: battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 50 battery.date: 2001/09/25 battery.mfr.date: 2007/12/28 battery.runtime: 997 battery.runtime.low: 120 battery.temperature:
2007 May 07
3
newhidups/APC: load always 0?
'lo, UPS model: APC Back-UPS BR 800 (supplied by Dell) My USB connection: Bus 001 Device 002: ID 051d:0002 American Power Conversion Back-UPS Pro 500/1000/1500 # upsc desk@localhost|grep load ups.load: 0.0 This UPS has 2 pc's and some minor other gear connected, yet the load stays at 0.0 when checking with nut. driver.version: 2.0.5 driver.version.data: APC/CyberPower HID 0.9
2008 Jul 03
4
Old APC SmartUPS 1250, Nut 2.2.2 Fedora 9
Hi All, I've got two APC SmartUPS's that behave differently with nut, I have a SmartUPS1400 & a SmartUPS1250. I'm fairly sure this isn't a nut problem but more likely a problem with the age of the SmartUPS1250 and the apcsmart driver not being able to identify it. Under the APC Powerchute software the same monitoring & command parameters are available for both
2009 Oct 11
1
demo site
Hi Arnaud, The demo site for NUT appears to be unreachable: $ demo.networkupstools.org Host demo.networkupstools.org not found: 3(NXDOMAIN) Maybe the recent DNS changes have something to do with it? Additionally, please note that, as of October 26th this year, I am no longer making any guarantee that my home server, which is still used for the demo site, will stay up 24h/24. In my new flat,
2018 Mar 03
2
APC UPS wrong input voltage
Folks, I've asked this question on the FreeNAS forum but there are no ideas there as it looks like it's a NUT issue. Original question: https://forums.freenas.org/index.php?threads/apc-ups-reporting-wrong-input-voltage.60888/ the nut driver is reporting the wrong input voltage. I am in the UK, 230V but it's reporting circa 108. If I connect it to the laptop and run powerchute it
2005 Oct 17
0
Re: Feedback: Back-UPS RS 800 USB works with NUT
Hi Klaus, Thanks for your much appreciated feedback. Klaus Holler wrote: > Hello, > >I just wanted to report that the Back-UPS RS 800 works with the >Network UPS Tools. Currently I use the following (Ubuntu breezy) >debian packages on kernel 2.4.31: >ii nut 2.0.2-1build1 >ii nut-usb 2.0.2-1build1 > >lsusb reports: >ID 051d:0002 American Power Conversion Back-UPS Pro
2014 Jul 09
2
APC SmartUPS switches off with no reason
Hello One our customer has two Linux HP-branded servers powered from "clasic" APC Smart-UPS 2200 RM 2U (p/n SUA2200RMI2U). It is connected to first server via RS232c port with APC-branded cable. We have installed NUT 2.6.4 with apcsmart driver. This setup works fine for months. Two weeks ago all the hardware powered from the UPS started to switch off occasionally while on line
2012 Dec 04
2
Does NUT include support for older UPSD servers?
I have a network with two older systems protected by APC UPSs. Both systems run OS/2 and will continue to do so. Both systems have APC PowerChute Plus 4.2.3 installed and I can use that software to monitor and control both systems. I am also now running several linux systems, in fact I spend almost all my time on the linux systems and these OS/2 systems are servers running in the
2008 Apr 15
3
Network UPS Tools version 2.2.2-pre2 released
Network UPS Tools version 2.2.2-pre2 has been released. http://www.networkupstools.org/ Direct access: - Download: http://www.networkupstools.org/source/2.2/testing/nut-2.2.2-pre2.tar.gz - News: http://www.networkupstools.org/source/2.2/testing/new-2.2.2-pre2.txt - ChangeLog: http://www.networkupstools.org/source/2.2/testing/ChangeLog Arnaud and the NUT team -- Linux / Unix Expert R&D -
2009 Feb 28
2
APC SMART-UPS 1500 always reporting LB
Using nut v2.2.2, and the APC serial cable. I have a client who's APC SMART-UPS 1500 (circa 2000) is always reporting LB. The batteries were old so they were replaced two weeks ago with brand new batteries. UPS still reported low batteries... I ran a calibration and a test on the unit (using the nut upscmd utility) During those tests, the battery charge on the unit goes to zero and slowly
2018 Mar 27
0
problem with nut APC BackUPS RS 1500 (white)
Hello, i have this strange problem with APC BackUPS RS 1500 ? older one model, white one under windows in powerchute is device OK, working everything ok selftest ok, just ordinary ups. under CentOS 7 minimal (CentOS-7-x86_64-Minimal-1708.iso) kernel version 3.10.0-693.el7.x68_64 driver version 2.7.2 i have this strange probem: nut driver didnt start automatically with error, after i enter in
2018 Mar 27
0
problem with nut APC BackUPS RS 1500 (white)
Hello, i have this strange problem with APC BackUPS RS 1500 ? older one model, white one under windows in powerchute is device OK, working everything ok selftest ok, just ordinary ups. under CentOS 7 minimal (CentOS-7-x86_64-Minimal-1708.iso) kernel version 3.10.0-693.el7.x68_64 driver version 2.7.2 i have this strange probem: nut driver didnt start automatically with error, after i enter in
2011 Dec 21
1
APC BZ1200-BR
Dear friends, I installed NUT and followed all suggested procedures to verify if my ups is supported. No driver recognized my ups, and the genericups tests get wrong. Here I send some informations about it: The ups model is APC BZ1200-BR I use Ubuntu, and the lsusb results Bus 003 Device 003: ID 0403:6001 Future Technology Devices International, Ltd FT232 USB-Serial (UART) IC for ups. The
2023 Apr 07
3
[PATCH 1/2] drm/i915: constify pointers to hwmon_channel_info
Statically allocated array of pointed to hwmon_channel_info can be made const for safety. Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski at linaro.org> --- This depends on hwmon core patch: https://lore.kernel.org/all/20230406203103.3011503-2-krzysztof.kozlowski at linaro.org/ Therefore I propose this should also go via hwmon tree. Cc: Jean Delvare <jdelvare at suse.com>
2005 Jul 08
0
APC Powerchute Network Shutdown, or APC Symmetra
Hello. We've got an APC Symmetra with a network management card. We'd like to run Powerchute Network Shutdown on some of our older Linux servers, but no dice. I'm wondering if anyone has found a way to make NUT work with the network mangement card (it's a TCP connection, not SNMP or cable), or knows of any alternate PCNS clients Also, I was wondering if anyone on the list has
2006 Feb 20
1
preventing automatic reboot
Hello, I'd like to prevent my servers from rebooting when power comes back after a power failure. With powerchute (which I used before), there is an "automatic reboot" parameter. Is there an equivalent with nut ? Regards -- Frantz de Germain Web : http://www.info.univ-angers.fr/pub/frantz Membre de la Soci?t? d'Astronomie de Nantes : http://www.san-fr.com/
2015 Jul 01
1
Need help
Hi, I run os x yosemite and found out about NUT tonight. I messed around with fink and macports but get stuck very soon. I dont know how to install anything that doesnt have a .dmg or .pkg installer. Does anyone have a step by step (written in "for dummies" format on how to get this all to work? Just looking for a PowerChute alternative that actually lets me control and monitor my
2008 Feb 04
2
[PATCH 0/2] Move /sys/o2cb to /sys/fs/o2cb
Hi Greg, The following two patches move /sys/o2cb into /sys/fs/o2cb as we previously discussed. A symlink is created to maintain compatibility with existing versions of ocfs2-tools. A patch to automatically search /sys/fs/o2cb has been committed to the ocfs2-tools repo and a release with that code shouldn't be too far out. Old versions of ocfs2-tools have been tested and work fine with the