Ivan Kuznetsov
2014-Jul-09 11:08 UTC
[Nut-upsuser] APC SmartUPS switches off with no reason
Hello One our customer has two Linux HP-branded servers powered from "clasic" APC Smart-UPS 2200 RM 2U (p/n SUA2200RMI2U). It is connected to first server via RS232c port with APC-branded cable. We have installed NUT 2.6.4 with apcsmart driver. This setup works fine for months. Two weeks ago all the hardware powered from the UPS started to switch off occasionally while on line power. The UPS switchs off too and need to be turn on manually. No any warnings or so logged by NUT. UPS load is <25-30%, battery is ok. With disconnected control cable the UPS forks as desired, no switch offs for 6 days. When customer connects the cable back the UPS switchs off after ~12 hours. It looks like the UPS recives 'instant poweroff' command via interface with no reason What can be a diagnostic procedure? -- Regards, Ivan Kuznetsov SOLVO ltd
Ivan Kuznetsov
2014-Jul-09 12:23 UTC
[Nut-upsuser] APC SmartUPS switches off with no reason
Customer says the control cable is APC 940-0024D
Matus UHLAR - fantomas
2014-Jul-09 12:38 UTC
[Nut-upsuser] APC SmartUPS switches off with no reason
On 09.07.14 15:08, Ivan Kuznetsov wrote:>One our customer has two Linux HP-branded servers powered from >"clasic" APC Smart-UPS 2200 RM 2U (p/n SUA2200RMI2U). It is connected >to first server via RS232c port with APC-branded cable. We have >installed NUT 2.6.4 with apcsmart driver. This setup works fine for >months. Two weeks ago all the hardware powered from the UPS started >to switch off occasionally while on line power. The UPS switchs off >too and need to be turn on manually. No any warnings or so logged by >NUT. UPS load is <25-30%, battery is ok. With disconnected control >cable the UPS forks as desired, no switch offs for 6 days. When >customer connects the cable back the UPS switchs off after ~12 hours. >It looks like the UPS recives 'instant poweroff' command via >interface with no reason > >What can be a diagnostic procedure?Hello, 20 years ago I was working with APC Smart UPS (1500 iirc) and I have noticed this behaviour: when power fell off with cable plugged in (powerchute not configured), the UPS turned power to my computer a few seconds after the outage. When the cable was not plugged in, the UPC did hold the power until it discharged. Therefore I think that the APC UPS needs to communicate with the computer when it's connected and it loses input power, otherwise it shuts output power down... I feel there something strange about APC UPS... -- Matus UHLAR - fantomas, uhlar at fantomas.sk ; http://www.fantomas.sk/ Warning: I wish NOT to receive e-mail advertising to this address. Varovanie: na tuto adresu chcem NEDOSTAVAT akukolvek reklamnu postu. On the other hand, you have different fingers.