similar to: Sola 305 with INT-0051 cable

Displaying 20 results from an estimated 100 matches similar to: "Sola 305 with INT-0051 cable"

2007 Sep 03
0
Tr : adding Jageson Technology JASUNY UPS support to NUT
Hi Shanan, Since I'm lagging too much on this point, I've forwarded your mail to the NUT development list, in the hope that another developer will have a bit of time to merge your patch. thanks for your contribution, Arnaud Quette -- Free Software Developer - http://arnaud.quette.free.fr/ Debian Developer - http://people.debian.org/~aquette/ Network UPS Tools (NUT) Project Leader -
2015 May 28
1
Fix for bug in arima function
>>>>> Patrick Perry <pperry at stern.nyu.edu> >>>>> on Wed, 27 May 2015 23:19:09 -0400 writes: {@PP, you forgot this part:} >>>>> peter dalgaard <pdalgd at gmail.com> >>>>> on Thu, 21 May 2015 14:36:03 +0200 writes: >> I suspect that what we really need is >> >> fitI <- lm(x ~
2015 May 21
3
Fix for bug in arima function
On 21 May 2015, at 12:49 , Martin Maechler <maechler at lynne.stat.math.ethz.ch> wrote: >>>>>> peter dalgaard <pdalgd at gmail.com> >>>>>> on Thu, 21 May 2015 11:03:05 +0200 writes: > >> On 21 May 2015, at 10:35 , Martin Maechler <maechler at lynne.stat.math.ethz.ch> wrote: > >>>> >>>> I noticed that
2015 May 21
0
Fix for bug in arima function
> I noticed that the 3.2.1 release cycle is about to start. Is there any > chance that this fix will make it into the next version of R? > > This bug is fairly serious: getting the wrong variance estimate leads to > the wrong log-likelihood and the wrong AIC, BIC etc, which can and does > lead to suboptimal model selection. If it's not fixed, this issue will > affect
2009 Mar 06
0
modifying a built in function from the stats package (fixing arima) (CONCLUSIONS)
Thanks a lot to everybody that helped me out with this. Conclusions: (1) In order to edit arima in R: >fix(arima) or alternatively: >arima<-edit(arima) (2) This is not contained in the "Introduction to R" manual. (3) A "productive" fix of arima is attached (arma coefficients printed out and error catched so that it doesn't halt parent loops to search for
2015 May 20
2
Fix for bug in arima function
I noticed that the 3.2.1 release cycle is about to start. Is there any chance that this fix will make it into the next version of R? This bug is fairly serious: getting the wrong variance estimate leads to the wrong log-likelihood and the wrong AIC, BIC etc, which can and does lead to suboptimal model selection. If it's not fixed, this issue will affect every student taking our time series
2015 May 21
0
Fix for bug in arima function
>>>>> peter dalgaard <pdalgd at gmail.com> >>>>> on Thu, 21 May 2015 11:03:05 +0200 writes: > On 21 May 2015, at 10:35 , Martin Maechler <maechler at lynne.stat.math.ethz.ch> wrote: >>> >>> I noticed that the 3.2.1 release cycle is about to start. Is there any >>> chance that this fix will make it into
2005 Oct 03
1
CyberPower SL-series
This code, added to drivers/genericups.h, supports the CyberPower SL series UPSes. I've tested with my 725SL - the online/on battery transition, and low battery status, and finally the shutdown signal all work as expected. *** genericups.h.orig Sun Nov 2 16:54:24 2003 --- genericups.h Mon Oct 3 13:49:00 2005 *************** *** 220,225 **** --- 220,234 ---- TIOCM_ST
2007 Jan 28
2
sweex 1000VA LB OB issue
Hello folks, I have a question regarding a sweex product. Its bundled with UPSmart v 2.12. I installed nut accordingly to the user manual included in the software. A quick check of data/drivers.list revealed to me i should use the: "Sweex" "500/1000" "contact closure - shipped with UPSmart" "genericups upstype=7" driver this driver
2015 May 21
2
Fix for bug in arima function
On 21 May 2015, at 10:35 , Martin Maechler <maechler at lynne.stat.math.ethz.ch> wrote: >> >> I noticed that the 3.2.1 release cycle is about to start. Is there any >> chance that this fix will make it into the next version of R? >> >> This bug is fairly serious: getting the wrong variance estimate leads to >> the wrong log-likelihood and the wrong
2009 Aug 14
2
Bestfortress driver, network serial patch for nut-2.0
Best fortress support was understandably dropped, but we still use them, and someone else may want the driver I ported to nut-2.0. We also often attach the serial cable from a UPS to a network terminal server, since servers these days don't come with very many serial ports. (They call them "legacy" ports.) I submitted a patch to support these for nut-1.x, and it was rejected
2011 Mar 17
0
Gelman-Rubin convergence diagnostics via coda package
Dear, I'm trying to run diagnostics on MCMC analysis (fitting a log-linear model to rates data). I'm getting an error message when trying Gelman-Rubin shrink factor plot: >gelman.plot(out) Error in chol.default(W) : the leading minor of order 2 is not positive definite I take it that somewhere, somehow a matrix is singular, but how can that be remedied? My code: library(rjags)
2005 Nov 30
4
ups.conf configure
Hello, I got this information from the manufacturer of my ups Kobian/Mercury and were tested wtih powstatd on Linux (Works OK). Now i want to configure it with NUT and i didn't have any luck (it always says OB) Initiliasation for monitoring: RTS = 1 (High) Main power fail: CTS = 0 (Low) Batter low: DCD = 0 (Low) Kill UPS: DTR = 0 (Low) How would the ups.conf look like? Reagards, Lep
2008 Jul 25
3
CyberPower 550SL reports LB and OB when on line power
I am using nut 2.2.2 and I have a CyberPower CP550SL. According to the drivers list, I should be using genericups with upstype set to 7, but when I try that and when I run upsc I get: driver.name: genericups driver.parameter.LB: 04 driver.parameter.pollinterval: 2 driver.parameter.port: /dev/ups driver.parameter.upstype: 7 driver.version: 2.2.2 driver.version.internal: 1.34 ups.mfr: CyberPower
2008 Jul 25
3
CyberPower 550SL reports LB and OB when on line power
I am using nut 2.2.2 and I have a CyberPower CP550SL. According to the drivers list, I should be using genericups with upstype set to 7, but when I try that and when I run upsc I get: driver.name: genericups driver.parameter.LB: 04 driver.parameter.pollinterval: 2 driver.parameter.port: /dev/ups driver.parameter.upstype: 7 driver.version: 2.2.2 driver.version.internal: 1.34 ups.mfr: CyberPower
2007 Oct 05
2
Working UPS report: Geek Squad GS-700U (Cyberpower clone?)
Hi, I wanted to report some success with monitoring this UPS, a "Geek Squad" brand GS-700U that I purchased earlier this year from Best Buy Canada. Information about this... thing is very scarce so here is what I know: The unit itself is probably made by Cyberpower. It has a 9-pin serial port on the UPS, as well as a serial-USB adapter thing. I cracked open the serial-USB
2007 Dec 06
7
[PATCH] Fix ioemu compile
# HG changeset patch # User john.levon@sun.com # Date 1196969481 28800 # Node ID 2c28ac4db1f7542220b1472821e8631b79b6a23a # Parent 4a98d4b6e4daccd610175e3c0f8cab49b056c649 Fix ioemu compile serial.c was including another Linux-specific header. Signed-off-by: John Levon <john.levon@sun.com> diff --git a/tools/ioemu/hw/serial.c b/tools/ioemu/hw/serial.c --- a/tools/ioemu/hw/serial.c +++
2013 Feb 11
1
UPS, ISB Sola basic, usb conection does not works
Hello people. My name is Rub?n. Firts, excuse me for my bad english. I run Debian 6.0.6, kernel 2.6.32-5-amd64 in my machine. I bought a ISB Sola basic UPS, model Micro SR inet, with usb conection. I Configure the nut.conf file in standalone mode and I install de isbmex driver. The ups.conf: [ISB_sola-basic] driver = isbmex port = auto With de command upsdrvctl start the
2002 Sep 03
0
Configure problems in samba 2.2.4 and 2.2.5 on both Irix and sola ris
I've built samba by hand before , but I've never seen this message, perhaps you can shed some light. I suddenly can't get past the ./configure script. ./configure --prefix=/usr/samba --with-winbind --with-automount gives me the following error: checking for conflicting AUTH_ERROR define in rpc/rpc.h ... no checking for test routines ... configure: error: can't find
2008 Feb 28
2
Unknown model detected - please report this ID: 'SOLA'
Some one might have answerd this, but I can not find any think yet I am trying to load a SOLA 610 700va ups up and keep getting : --------------------------------- Network UPS Tools - UPS driver controller 2.0.5 Network UPS Tools - MGE UPS SYSTEMS/U-Talk driver 0.88 (2.0.5) .Detected Pulsar ESV11+ on /dev/cuaa0 Network UPS Tools - Best UPS driver 1.03 (2.0.5) Unknown model detected - please