similar to: New intermediate Windows binaries release - 2.6.5-4

Displaying 20 results from an estimated 5000 matches similar to: "New intermediate Windows binaries release - 2.6.5-4"

2012 Sep 19
1
New intermediate Windows binaries release - 2.6.5-3
?Hello, There is a new intermediate Windows binaries release available at : http://www.networkupstools.org/package/windows/NUT-Installer-2.6.5-3.msi This fixes a regression about stopping the NUT service. Feedback is highly appreciated. Regards, Fred -- Eaton Opensource Team - http://opensource.eaton.com ----------------------------- -----------------------------
2012 Sep 17
1
New intermediate Windows binaries release - 2.6.5-2
?Hello, There is a new intermediate Windows binaries release available at : http://www.networkupstools.org/package/windows/NUT-Installer-2.6.5-2.msi This fixes three regressions: - upssched was not working - Event logging was not working (unless for NUT service binary itself) - usbhid-ups was not working with Back-UPS ES ups. Feedback is highly appreciated. Regards, Fred -- Eaton
2012 Aug 08
1
Network UPS Tools version 2.6.5 released
Network UPS Tools version 2.6.5 has been released: http://www.networkupstools.org/ Among the many improvements and bugfixes, this release fixes the upssched regression, that rendered it unusable. Update to 2.6.5 is thus highly recommended. As noted in the news, website hosting is under migration. While I don't expect any service disruption, please report any issue you may face. Direct
2013 Jan 10
1
Eaton 5PX1500RT
Windows 7 x64 NUT 2.6.5-4 Eaton 5PX1500RT Using explore did not yield any additional output. This UPS is on the compatibility list, so hopefully not a big deal. I double-checked that the 3S still works with the same USB cable. I'll check mge-shut over serial next. Regards. -------------- next part -------------- Network UPS Tools - Generic HID driver 0.37 (2.6.5-3780M) USB communication
2012 Sep 13
2
Early shutdowns and 2.6.5-1 package for Windows
Hello NUT Team! I am testing the early shutdowns in NUT 2.6.5-1 package for Windows (Windows 7 x64). My configuration files: upsmon.conf RUN_AS_USER upsmon MONITOR upsa at 192.168.10.200 1 upsmon pass master MINSUPPLIES 1 SHUTDOWNCMD "/sbin/shutdown -h +0" NOTIFYCMD "upssched.exe" POLLFREQ 5 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME 15 POWERDOWNFLAG
2012 Oct 11
4
Eaton 3S550
Windows 7 Pro x64 Eaton 3S550 (brand new, battery mfg 8/15/2012) NUT 2.6.5-3 ups.status: OL CHRG CHRG was present even though it has been plugged in a few days turned on and battery.charge was 100%. Log includes me running upsc and removing power long enough to see that battery.charge will decrease. This UPS doesn't have controlled outlets despite what the upsc output says. ---
2012 Sep 10
2
For APC Back UPS ES users
?With Arnaud Quette's help, I have tried to fix the regression concerning the APC Back UPS ES unit. This regression is related to an issue in this UPS firmware. It cannot be reverted to previous version because the current code fixes communication issue with others UPS (which behave correctly, but are not very permissive). So we (Arnaud and I) have decided to add a tweak (call it a hack if you
2012 Nov 08
1
APC Back UPS ES 700
Hello! I have tested APC Back UPS ES 700 and NUT 2.6.5-3 a few days ago and I have got some news. This device is detected by nut-scanner as: [nutdev1] driver = "usbhid-ups" port = "auto" vendorid = "051D" productid = "0002" product = "Back-UPS ES 700 FW:829.D2 .I USB FW:D2 " serial =
2012 Sep 12
1
Problem with APC Back-UPS CS 650 and FreeNAS 8.3.0 BETA 2
Hi all ! I have a little problem using NUT from FreeNAS. Operating system FreeBSD 8.3-RELEASE-p4 (FreeNAS 8.3.0 BETA 2) UPS American Power Conversion/Back-UPS CS 650 FW:817.v7 .I USB FW:v7 NUT Driver Network UPS Tools - Generic HID driver 0.37 (2.6.5) USB communication driver 0.31 Trying to configure the UPS from FreeNAS failed so I try to investigate which is the problem. Running
2012 Apr 26
3
NUT 2.6.3-1 Windows package
Hello all, There is a new Windows package of NUT. It now contains nut-scanner binary. Note that there is a known issue with libupsclient.dll with nut-scanner. The scan of NUT servers using nut-scanner will not work for now. You can find it at : http://www.networkupstools.org/source/2.6/NUT-Installer-2.6.3-1.msi Please send feedback to the list. Regards, Fred -- Team Open Source Eaton -
2012 Sep 06
1
nut-scanner pthread issue
Hi, the terminating part of nut-scanner can crash in pthread code, because some threads won't exist. For example snmp part: ============================== if( allow_snmp && nutscan_avail_snmp ) { if( start_ip == NULL ) { printq(quiet,"No start IP, skipping SNMP\n"); } else { printq(quiet,"Scanning SNMP bus.\n"); #ifdef HAVE_PTHREAD if(
2012 Jul 21
1
Windows NUT shutdown UPS?
I was wondering what you guys do about UPS shutdown on Windows systems? Apcupsd has the same issue, so I'm assuming it is the same with NUT. Windows just makes it hard/impossible to do. Do you find draining the batteries down so much cause issues for longevity? Regarding my Eaton 5110, I found that automatic driver setup works just fine on Windows XP but not at all on Windows 7 x64 (I
2012 Aug 30
1
Data stale and Back UPS ES
Hello! I tried NUT 2.6.5-1 (Windows port) with my APC Back UPS ES. It seems I have configured NUT properly, nut-scanner found my UPS: [nutdev1] driver = "usbhid-ups" port = "auto" vendorid = "051D" productid = "0002" product = "Back-UPS ES 525 FW:851.t3.I USB FW:t3" serial = "8B0745R23575
2012 Aug 24
1
Perhaps a Complicated Question
My network at home/home office is primarily a Windows environment. However, I have 3 ReadyNAS Ultra machines which use NUT for UPS monitoring. The ReadyNAS devices are running a slightly modified Debian (2.6.37.6.RNx86_64.2.4) with NUT 2.0.5. What I would like to do is add some sort of web-based UPS monitoring on my intranet web server (IIS 7.5 on 2008 R2), however nut-cgi appears to be
2012 Sep 11
1
Back UPS ES and data stale with disconnected device
Hello NUT Team! I continue playing with NUT for Windows and USBHID-UPS driver I've got from Frederic to fix "Data Stale" problem. It seems there is something wrong when Network UPS Tools service is starting with disconnected USB cable. UPSMON is writing "Data Stale" to output and continue do it infinitely, even the cable is connected back. Here is a short log: Network
2012 Jul 23
2
getting nut 2.6.4 working in Nas4Free
I'm trying to use a Nas4Free storage system. This same hardware worked fine on Freenas 0.7.2. O/S: Nas4Free 9.0.0.1.148 which comes with nut 2.6.4. UPS is an APC Back UPS RS 800. USB interface. Driver : usbhid-ups Port: auto my NAS is communicating with the UPS, but in testing power failures, I'm not getting the shutdown to be handled properly. When I pull the AC plug on the UPS,
2011 Jul 26
5
Problem with upsmon on x64 Windows
Hello! I try use NUT on some servers. When i use this package on x64 Windows 2003 servers, upsmon hangs on with error: Faulting application upsmon.exe, version 0.0.0.0, faulting module upsmon.exe, version 0.0.0.0, fault address 0x0000458f. I try use another server, on 32-bit all is ok. Problem only on x64 platform (maybe in libusb)? And no different - upsmon master or slave. C:\Program Files
2011 Jun 28
3
Changes to upscli_connect
Hello, I am currently working on the nut scanner. For detecting available upsd on the network, I rely on upscli_connect. The problem with this function is that it calls a blocking "connect" function. So the nut-scanner is blocked while waiting for the TCP timeout when trying to connect to an IP without upsd available . Since this timeout may be rather long (3 minutes on my host), I
2012 May 02
1
NUT 2.6.3-3 Windows package
Hello all, Thanks to early feedbacks from Dmitry Ogorodnikov, we have made a new Windows package of NUT with previously missing DLLs allowing to run netxml-ups and snmp-ups drivers as well as nut-scanner tool. You can find it at : http://www.networkupstools.org/source/2.6/NUT-Installer-2.6.3-3.msi Please send feedback to the list. Regards, Fred -- Eaton Opensource Team -
2013 Jan 15
1
RFC Eaton serial scan
?Hello, I would like to merge branches/serial_nutscanner to the trunk. The attached patch contains the needed modifications. You can read docs/man/nutscan_scan_eaton_serial.txt to see what it is about and docs/man/nut-scanner.txt to see modification to nut-scanner tool interface. This adds about 100K to the libnutscan.so file. Regards, Fred -----------------------------