Displaying 20 results from an estimated 6000 matches similar to: "[HCL] CyberPower Systems PR6000LCDRTXL5U supported by usbhid-ups"
2012 Feb 22
1
[HCL] CyberPower OR700 supported by usbhid-ups
CyberPower OR700LCDRM1U (http://www.cyberpowersystems.com/products/ups-systems/smart-app-ups/rackmount-lcd/OR700LCDRM1U.html)
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 6000
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 14.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS OR700
2017 Nov 10
2
Cyberpower PR2200ELCDRT2U
Dear Charles,
thanks for your quick answer and your information! I didn't know there is a difference in the PR-series between old and new. So thanks for this valuable information!
usbconfig dump_device_desc shows:
ugen0.2: <CyberPower Systems product 0x0601> at usbus0, cfg=0 md=HOST spd=LOW (1.5Mbps) pwr=ON (50mA)
2017 Nov 12
0
Cyberpower PR2200ELCDRT2U [HCL]
On Nov 10, 2017, at 5:31 PM, Christoph Lampl <chris at weeone.de> wrote:
>
> Dear Charles,
>
> thanks for your quick answer and your information! I didn't know there is a difference in the PR-series between old and new. So thanks for this valuable information!
Just a lucky guess :-) We tend not to know about changes like this until someone reports an issue.
>
>
2017 Sep 28
1
[HCL] CyberPower EC350G supported by usbhid-ups
[shutdown sequence]
I have tested and verified the shutdown sequence works.
[manufacturor]
https://www.cyberpowersystems.com/product/ups/ec350g/
mbeisser at nas:~$ upsc ups
Init SSL without certificate database
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1575
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 9.3
2013 Nov 22
0
[HCL] CyberPower LE825G supported by Cyber Power Systems ups 2 685AVR USB (usbhid-ups) driver
CyberPower Battery Backup with Surge Protection, model LE825G
Appears to function properly with the driver listed on the HCL for the
Cyber Power Systems ups 2 685AVR USB (usbhid-ups).
Tested with shutdown mode "UPS Goes On Battery" with a 5 second timer
and the system successfully shutdown as expected.
upsc output:
upsc ups
battery.charge: 100
battery.charge.low: 10
2019 Mar 06
0
HCL Cyberpower CPS-850AVRLCD supported by usbhid
Cyberpower CPS850avrlcd
https://www.cyberpowersystems.com/product/ups/cp850avrlcd/
shutdown sequence: UNTESTED
upsc output:
_____
sudo upsc cp-ups
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1230
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 13.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS
2020 Oct 26
2
Can't get CyberPower UPS to work with Raspberry Pi 4
On Monday 26 October 2020 09:01:31 Charles Lepple wrote:
> On Oct 25, 2020, at 11:52 AM, Robert Stocker <kneadtoknow at gmail.com>
wrote:
> > Init SSL without certificate database
> > battery.charge: 100
> > battery.charge.low: 10
> > battery.charge.warning: 20
> > battery.mfr.date: CPS
> > battery.runtime: 15690
> > battery.runtime.low: 300
2012 Aug 30
2
UPS - CYBERPOWER CPS DX600E supported by usbhid-ups
UPS - CYBERPOWER CPS DX600E
upsc usb at localhost
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1650
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 4.8
battery.voltage.nominal: 12
device.mfr: CPS
device.model: DX600E
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
2018 Sep 26
0
[HCL] Cyber Power Systems AVRG750U supported by usbhid-ups
Cyber Power Systems AVRG750U
https://www.cyberpowersystems.com/product/ups/avrg750u/
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 15360
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 24.0
battery.voltage.nominal: 24
device.mfr: CPS
device.model: AVRG750U
device.serial: <REDACTED>
device.type: ups
2024 Mar 21
2
CyberPower PR3000LCDRTXL2U and NUT 2.8.0 - mute?
I have a CyberPower PR3000LCDRTXL2U with a BP48V75ART2U expansion
chassis, which I am monitoring using NUT 2.8.0 (on Gentoo Linux). TThe
UPS appears to be telling me that the batteries need replacement due to
age. CyberPower support has confirmed that for me and told me how i
should be able to mute the alarm from the front panel until I can
replace the batteries, but it doesn't appear
2017 May 14
2
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
[updated]
OpenBSD 6.1/amd64
NUT 2.7.4p0 (from OpenBSD package)
Results of upsc:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 2902
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 26.9
battery.voltage.nominal: 24
device.mfr: CPS
device.model: CP1500AVRLCDa
device.serial: CTHGN200xxxx
device.type: ups
driver.name:
2020 Oct 25
4
Can't get CyberPower UPS to work with Raspberry Pi 4
This was very helpful for me, thank you!
On Sat, Oct 24, 2020 at 9:06 AM Charles Lepple <clepple at gmail.com> wrote:
> The easiest way to tell if upsd is working is to run "upsc -l" on the same
> system, which will list the NUT UPS names, and then run e.g. "upsc mge"
> (replacing "mge" with the name returned by "upsc -l")
>
Here was the
2015 Feb 06
0
[HCL] <CyberPower> <Value 1500ELCD-RU> supported by <usbhid-ups>
CyberPower Value 1500ELCD-RU
root at ubuntu:/home/oper# upsc myups at localhost
battery.charge: 87
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 5220
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 16.5
battery.voltage.nominal: 24
device.mfr: CPS
device.model: Value1500E
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq:
2016 Dec 08
2
[HCL] Cyber Power Systems EC750G supported by usbhid-ups
I didn't want to sign up for the nut-devs list or create a git account
just to provide this information, so I hope posting this info here is OK...
I just bought a Cyber Power Systems EC750G UPS for use as a spare. Here
are some info for it:
=========================
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime:
2007 Jul 14
2
Cyberpower USB CP550SL RT (AE550)
Hello,
I have the Cyberpower USB CP550SL RT< whats its called when i bought it :) (AE550 according to upsc) and i think its missing some monitor options such as load, wattage use, temp..etc (shows in powerpanel pro,personal ed under win) ..it seem to be really lacking
the only options i get are
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.runtime: 4560
2017 May 14
0
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
OpenBSD 6.1/amd64
NUT 2.7.4p0 (from OpenBSD package)
Results of upsc:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 2902
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 26.9
battery.voltage.nominal: 24
device.mfr: CPS
device.model: CP1500AVRLCDa
device.serial: CTHGN200xxxx
device.type: ups
driver.name: usbhid-ups
2012 Nov 16
1
CyberPower DX600E won't switch up after power is back
Hello
I have an issue with an CyberPower DX600E,
it doesn't switch up when the power is back; after it has been
unloaded;
is it because of one of those variables ?
regards
Franck
#upsc myups
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1380
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 4.7
2016 Jan 18
4
NUT support for CyberPower PR1500LCDRTXL2Ua
Hey all,
I ended up picking up the module listed in Subject line.
I switched over my config but apparently not all going smoothly.
My config is:
[office]
driver = powerpanel
port = /dev/ttyS0
desc = "Office UPS"
When I test the driver running power-panel as a test, I get:
> [root at cornelius init.d]# powerpanel -a office -D -D -D -D
>
2017 Nov 10
3
Cyberpower PR2200ELCDRT2U
Hey guys, :)
recently, I installed Cyberpower PR2200ELCDRT2U, however, I have not managed to get this UPS working with FreeNAS 11, yet.
According to compatibility list, PR2200 should work fine, when using powerpanel driver:
http://networkupstools.org/ddl/Cyber_Power_Systems/
http://networkupstools.org/ddl/Cyber_Power_Systems/PR2200.html
However, when trying to establish a connection between
2012 Nov 23
2
CyberPower DX600E won't switch up after power
> Subject: [Nut-upsuser] CyberPower DX600E won't switch up after power
> is back
> Message-ID: <3c530815d1ea602efdfec0d67eb1e0b1 at secretfatty.net>
> Content-Type: text/plain; charset=UTF-8; format=flowed
>
> Hello
> I have an issue with an CyberPower DX600E,
> it doesn't switch up when the power is back; after it has been
> unloaded;
> is it because