similar to: [RFC apcsmart V3 00/18] apcsmart driver updates

Displaying 20 results from an estimated 1000 matches similar to: "[RFC apcsmart V3 00/18] apcsmart driver updates"

2011 Feb 07
4
[PATCH/RFC v2 0/3] Updates to ACP smart driver
This is 2nd version of the earlier patch featuring a few new features and fixes to the apcsmart driver, following the remarks in: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02294.html Major changes from v1: - handle battery.charge and battery.runtime checks at main.c level - handle "immutable but writable" conflict gracefully at driver level -
2011 Jan 25
1
[RFC] Updates to ACP smart driver
This patch introduces a handful of new options, I mentioned earlier in: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02088.html See the large commit message in the follow-up for the details and rationale. I realize it's a bit larger diff - so if it's required I can split it into few smaller ones. Michal Soltys (1): APC smart driver update and new features.
2007 Jul 31
1
Proposed apcsmart driver patch
G'day y'all, Here's a tiny patch set for drivers/apcsmart.c and drivers/apcsmart.h. Adds APC SmartUPS 1250 ("8QD" case) + 940-0024C recognition to apcsmart. (Unpatched apcsmart.c v1.99.8 misidentifies the SmartUPS 1250 as a "dumb" UPS.) For NUT 2.0.5+. NUT 2.0.5: Patches apply successfully. Builds successfully. Works as expected under Ubuntu 7.04. NUT 2.2:
2007 Jun 04
2
APCsmart serial port problem
I have a new APC Smart-UPS SUA2200RM2U. I've had no success with the manufacturer's PowerChute software and smart signaling, so I have decided to try NUT. The smartups driver can't make contact through the serial port. Since this is rack-mounted, it comes with a 940-1524 serial cable. As far as I can tell, this is supposed to work with smart signaling. Here's my ups.conf:
2011 Oct 03
2
patch: Replace many usleep and some sleep calls with nanosleep
Description: Replace many usleep and some sleep calls with nanosleep. usleep is stated in its manual page as removed by POSIX. Contrary to its predecessors, nanosleep semantics is well defined. The replacement, which is mostly in drivers, is untested. Supplements http://bugs.debian.org/633791. Last-Update: Sat, 13 Aug 2011 14:04:48 +0300 Index:
2010 Apr 19
1
Patch for the bestfortress driver 0.02
I could not make the bestfortress driver 0.02 work for my Best Fortress LI675VA, so I have made a patch for the driver. The reason was, that all responses are preceded and terminated by CR LF, but the driver would discard everything after the first CR LF. The following patch discards everything up to the first LF. It also adds a debugging feature of displaying the accepted data (level 5 i.e. -D
2009 Jun 25
1
Runaway apcsmart process
On several occasions I have seen the apcsmart process runaway using 100% CPU while filling my syslog partition by logging the following syslog entries at an incredible rate. I have seen up to 21,800 log entries PER SECOND of the following nature: --[snip]-- Jun 25 10:06:38 servername apcsmart[4012]: Communications with UPS lost: Communications with UPS lost - check cabling Jun 25 10:06:38
2011 May 19
2
Scheduling NUT 2.6.1
Fellows, time has come for a new NUT release: I'm planning on 2.6.1 next week (max Friday 27), and I'm currently processing remaining patches. If you have some more on your side, please send in. cheers, Arnaud -- Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/ Debian Developer -
2006 May 12
1
Fwd: RE New xanto driver for NUT
Dear Andreas, some googling revealed, you created a driver for the xanto series of online-usv.de. In what state it is currently? I've to manage a S2000 and would like to use nut for it, is it usable by now? Do you need another tester? TIA, Pete
2009 Jul 06
3
Smart-UPS RT 3000 Baud Rate
I have been running a Smart-UPS RT 3000 VA using nut successfully over the 940-0095B cable for a couple of years. I have just received a second unit, but it is slightly different in 3 ways that I have found so far. 1. It's a Smart-UPS RT 3000 XL 2. The 940-0095B cable now uses an RJ45 connector at the UPS end. 3. It now requires a baud rate of 9600 instead of the 2400 used previously.
2008 Dec 24
1
Driver removal notification: al175
Hi Kirill, just to notify you that your al175 driver is being removed from the NUT tree, as of 2.4.0-pre1. if you wish to see it entering the tree again, please contact the Development mailing list to talk about it. Merry Christmas and happy New Year. Arnaud -- Linux / Unix Expert R&D - Eaton - http://www.eaton.com/mgeops Network UPS Tools (NUT) Project Leader -
2006 Jun 19
4
Backups 300VA (BK-300C) Drivers
Hi, What driver should i use with APC BK-300C ? Michale Plourde Digicom Technologies
2009 May 04
1
Patches for NUT 2.2.2: APC SmartUPS-900
2009/5/3 Thomas Juerges > -----BEGIN PGP SIGNED MESSAGE----- > Hash: SHA1 > > Hi Arnaud, > Hi Thomas, > I just checked the 2.4.1 version of nut and found that you forgot to add > my old UPS model (APC Smart-UPS 900). I guess it is because you were > busy at the time when I sent you the patch. So here it goes again. :) > uh, right sorry. I was pretty sure I applied
2006 Nov 25
2
patch for old APC Smart-UPS 600
Hi there, I am using an old (really old) APC Smart-UPS 600. It worked fine under apcupsd but when I tried NUT it did not work. The error I was getting was: sudo /lib/nut/apcsmart -DDD /dev/ttyS1 Network UPS Tools (version 2.0.4) - APC Smart protocol driver Driver version 1.99.8, command table version 2.0 debug level is '3' Attempting firmware lookup Firmware: [D4] Not found in
2006 Feb 20
1
preventing automatic reboot
Hello, I'd like to prevent my servers from rebooting when power comes back after a power failure. With powerchute (which I used before), there is an "automatic reboot" parameter. Is there an equivalent with nut ? Regards -- Frantz de Germain Web : http://www.info.univ-angers.fr/pub/frantz Membre de la Soci?t? d'Astronomie de Nantes : http://www.san-fr.com/
2005 Sep 15
2
Driver for Tripp Lite SmartPro SLT
I have a new SMART1050SLT Tripp Lite UPS that both tripplite and tripplitesu drivers hate. Both simply time out with a "can't find" message. Does anyone know about the SmartPro series?
2008 Apr 18
2
My APC ups shutdown but doesn't start again
Hello, My APC Ups uses nut to manage all systems connected to it. But if online power failed until it shutdown, it not restart automatically after the power returned. It stay down until i restart it. When i execute the command: # upsc siUps1 it output me this: battery.alarm.threshold: L battery.charge: 018.0 battery.charge.restart: 15 battery.date: 03/31/07 battery.runtime: 120
2011 Mar 12
2
[RFC/PREVIEW] Move apcsmart driver to canonical processing + minor stuff
Inital tests with two apc units (2005 and pre-2000) seem to go well. See commit message for details. I'll add more detailed rationale after getting some sleep :) Michal Soltys (1): apcsmart: switch processing to ICANON + minor fixes drivers/apcsmart.c | 270 +++++++++++++++++++++++++++++++++++----------------- drivers/apcsmart.h | 127 ++++++++++++++++--------- 2 files changed, 267
2006 Nov 26
1
Patch for optiups to support Zinto D from ONLINE USV-Systeme AG
Hi Arnaud, Hi Scott, Hi list, Here is a patch to support the Zinto D from ONLINE USV-Systeme AG. I already sent a version to Russell Kroll (2006-04-09), without no response and I cannot find support for Zinto in svn until now. I found a discussion on this list about the Xanto from ONLINE, but the Zinto seems to use different commands. The commands are quite similar to those for Opti-UPS, so I
2011 Mar 21
2
apcsmart question
Before I start any commits. In patch 2/18 - http://lists.alioth.debian.org/pipermail/nut-upsdev/2011-March/005299.html Two "custom" commands slipped in: ups.firmware.old and shutdown.return.grace. In 18/18 I tried to rename them and add remainig commands for "hackish" shutdown methods, to make them easily callable through e.g. upscmd (for example for testing). Is it