similar to: Powercom BNT-1200AP

Displaying 20 results from an estimated 1000 matches similar to: "Powercom BNT-1200AP"

2007 Dec 24
3
Driver for Powercom BNT/KIN/IMP/IMD series
Hello all. Try this driver (for nut 2.2.0). See attach. - Trust, KP625AP, Egys models stay as it was - add Powercom's Black Knight Pro model support ( BNT-400/500/600/800/801/1000/1200/1500/2000AP 220-240V ) - add Powercom's King Pro model support ( KIN-425/525/625/800/1000/1200/1500/1600/2200/3000/5000AP[-RM] 100-120,200-240 V) - add Powercom's Imperial model support ( IMP-xxxAP,
2006 Dec 22
1
Powercom BNT-1200AP driver
Hello. What about driver for my UPS? I have changed the powercom driver for myself, but I have made it not absolutely correctly. However, somehow this driver works. Now i have protocol spec for powercom BNT series and attach it to this email. It can be interesting to authors? -- ? ?????????, ??????? ??????? mailto:alex@reutman.ru JID: alex@reutman.ru ICQ: 5052225 -------------- next part
2006 Dec 11
2
howto setup BNT-1500AP on gentoo
Good afternoon. I try to put nut on gentoo. Has executed installation by a standard command emerge nut. All has passed successfully. I use UPS POWERCOM BNT-1500AP. It is connected to serial port 1, i.e. for my system it/dev/tts/0. In/etc/nut/ups.conf [powercom] driver = powercom port = /dev/tts/0 desc = "PowerCom BNT-1500AP on IP-PBX" modelname = "BNT-1500AP" linevoltage = 230
2007 Nov 06
1
BNT-1000AP
Hi guys, We've got a BNT-1000AP (powercom) BlackKnight UPS that works with the KIN1500AP model in the powercom driver. Well, almost. It seems the input frequency and the battery charge is swapped around: # upsc blackknight at localhost battery.charge: 46.5 driver.name: powercom driver.parameter.manufacturer: BlackKnight driver.parameter.modelname: BNT-1000AP driver.parameter.port:
2013 May 01
1
Powercom BNT-1500AP serial config
Hey all, Finally got around to hooking up my Powercom BNT-1500AP to nut. It's the old serial interface. Connects okay and gets most information, but a couple of data are way off. Any config recommendations or upgrade recommended? I've played with config a little, but no hits yet. Details: NUT version 2.4.3 ups.conf: [ups] driver = powercom port = /dev/ttyS0
2011 Oct 04
2
PowerCOM BNT-800AP (0d9f:0004)
Hello. I've been trying to got it work but haven't luck. I'm using NUT 2.6.0-1 under Windows XP with libusb driver installed (USB\VID_0D9F&PID_0004&REV_0001). I had tryed all options with such config: *PWCOM] driver = usbhid-ups port = auto vendorid = 0d9f desc = "Powercom BNT-800AP" type=BNT* * *Here is output from CMD:*
2006 May 17
2
NUT LynxOS port
Hi, This patch includes port of NUT to LynxOS 4.0. The patch is against yesterday's svn tree. Here is a brief description of changes: drivers/powercom.c: Rename shutdown() to shutdown2(). shutdown() is already defined in LynxOS system header files. Please feel free to rename it more appropriately. (I didn't do it due to lack of imagination :-) ) include/proto.h: Added
2009 Jul 27
1
Powercom BNT-1000CS
Hello. I have recently purchased a Powercom BNT-1000CS(Black Knight CS). I am new to NUT(and am not a programmer), but I have noticed that this model does not work with NUT. I am willing to provide details about this UPS for anyone who would like to add support for it(i dont know how to get much info though, so you'll have to tell me how). For starters, this is what happens when I do
2017 Apr 28
3
Powercom BNT-2000AP(USB)
Hello all! Some days ago we received new UPS?Powercom BNT-2000AP with USB interface to replace an old staff and I've spent four last days trying to connect it with NUT. I have a FreeBSD 8.4 box with NUT 2.7.2. # dmesg|grep -i powercom ugen0.3: <POWERCOM Co.,LTD> at usbus0 uhid0: <POWERCOM Co.,LTD HID UPS Battery, class 0/0, rev 1.10/0.01, addr 3> on usbus0 uhid0: <POWERCOM
2012 Nov 13
1
PowerCom BNT-600AP on ubuntu 12.04.1 AMD64
Hello people, I use a BNT-600AP from PowerCom, and on driver loading (nut service start) the UPS goes off so I cannot use nut as service as the computer goes off with the UPS. When the computer is not using the UPS, but still connected, I see that the UPS goes off for a very short time, does battery check and goes on again. I don't know how to deal with this issue as I cannot use my UPS
2013 Jun 08
0
several problems with Powercom BNT-500AP
On Jun 5, 2013, at 11:49 AM, M?rti?? Pu??tis wrote: > Driver debug output attached. The debug output looks normal (many devices do not implement the interrupt pipe; hence, the timeouts). Unfortunately, we might need the log over a longer period of time, including your observations as to when various events occurred (such as transitions to battery). -- Charles Lepple clepple at gmail
2013 Jun 05
2
several problems with Powercom BNT-500AP
OS name and version: pi at raspberrypi ~ $ cat /etc/*release PRETTY_NAME="Debian GNU/Linux 7.0 (wheezy)" uname -a Linux raspberrypi 3.6.11+ #393 PREEMPT Fri Mar 8 16:36:28 GMT 2013 armv6l GNU/Linux exact NUT version pi at raspberrypi ~ $ dpkg -s nut Package: nut ... Version: 2.6.4-2.3 NUT installation method: package exact device name and related information:
2013 Jun 08
0
several problems with Powercom BNT-500AP
On Jun 8, 2013, at 12:57 PM, M?rti?? Pu??tis wrote: > I'll take a longer driver log. This page (http://www.networkupstools.org/support.html) says that to take a driver log NUT should be stopped, so I won't be able to tell when these events occurred within a driver log. Hmm, I didn't realize it said that, but I think that's to prevent having two copies of the same driver
2011 May 17
3
Powercom issues in NUT (was: PowerCom BNT2000AT ups on nut 2.6.0 - second try)
Dino, Alexey, there are a number of users suffering issues with your Powercom devices. Could you (Dino, and Keven if possible) please have a look at the below one, from Angela, and check for a fix? I've scheduled to release 2.6.1 next week, and having that fixed is part of the list. 2011/5/16 Angela Williams <angierfw at gmail.com> > Hi All > > On Friday 13 May 2011 at
2013 Jun 11
0
several problems with Powercom BNT-500AP
[I am CC'ing Alexey from Powercom in case he has seen any of these issues with the Raspberry Pi hardware.] On Jun 10, 2013, at 1:05 PM, M?rti?? Pu??tis wrote: > I took the log. Here's what happened. > Broadcast Message from nut at rasp > (somewhere) at 16:18 ... > UPS BNT500AP at localhost battery needs to be replaced > > occurred when for the first time value
2005 Jul 06
0
Powercom BNT-1500AP
Hey all, Does anybody know there is a full working setup for the PowerCom BNT-1500AP. I got some stuff working with the Powercom driver and the type set to "KIN1500AP". But it seems that there is still missing usablity. I was wondering if anybody found any better configs? ---- excerpt of ups.conf [AVR1500] driver = powercom port = /dev/ttyS0 desc =
2013 Jun 08
2
several problems with Powercom BNT-500AP
Thanks for the support. Here's list of when transition to battery with return to utility power within a few seconds occurred in last few days: Wednesday 1:41 11:48 11:54 12:59 13:42 14:42 18:13 18:14 Thursday 5:23 Friday 5:12 7:39 7:43 Saturday 7:34 Here's list of when messages that battery needs replacement occurred: Wednesday 20:34 Thursday 9:07 23:09 Friday 18:25 Saturday 7:32 19:47
2007 Dec 29
1
Odd Values For Powercoms
All, I'm using the Powercom driver from 2.2 (not the one recently mailed to thelist). Since it's a KIN2200AP, I'm using the driver settings right from the manpage. All the values look "sane" when I'm on-line, but note some of the odd values (<-- Here) when on battery: Also, does anyone know if this UPS supports logging of the "boost" or
2013 Jun 10
2
several problems with Powercom BNT-500AP
I took the log. Here's what happened. Broadcast Message from nut at rasp (somewhere) at 16:18 ... UPS BNT500AP at localhost battery needs to be replaced occurred when for the first time value "1" was read as "UPS.PowerSummary.PresentStatus.NeedReplacement", on this line: 6409.240690 Path: UPS.PowerSummary.PresentStatus.NeedReplacement, Type: Input, ReportID: 0x0a,
2006 Jul 08
0
Powercom BNT-600AP and NUT (powercom driver)
Hello, I'm new there. I bought an UPS Powercom BNT-600AP. It's compatible in NUT with driver powercom and protocol type KIN1500AP. But I have a simple problem: the 'upsc' shows wrong values in battery.charge (maybe in other rows also /ups.load, voltages?/) - if battery is 100% charged it shows only 92.6% or 93.0%. I thing I have wrong values in driver parameters: batteryPercentage,