similar to: Cyberpower CP550SL/AE550 Serial

Displaying 20 results from an estimated 200 matches similar to: "Cyberpower CP550SL/AE550 Serial"

2007 Jul 14
2
Cyberpower USB CP550SL RT (AE550)
Hello, I have the Cyberpower USB CP550SL RT< whats its called when i bought it :) (AE550 according to upsc) and i think its missing some monitor options such as load, wattage use, temp..etc (shows in powerpanel pro,personal ed under win) ..it seem to be really lacking the only options i get are battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 20 battery.runtime: 4560
2006 Jun 17
0
CyberPower CP550SL / AE550 success
Hi, I finally got the serial cable for this CyberPower CP550SL / AE550, and have successfully tested the genericups type 7 driver. The shutdown delay is about 2 minutes after the shutdown signal, and that signal needs to be rather long, I got it to work with 20 seconds. I suspect that all CyberPower UPSes that are compatible with the Windows UPS service are type 7. All references to the
2007 Feb 07
2
Using USB CyberPower CPL550SL / AE550, not working with usbhid-ups driver.
So I just bought one of these fabulous CyberPower UPS devices from BestBuy hoping I could control it with my machine. Luckily, I found NUT! I've got the SVN sources and compiled and installed them but I haven't been able to get it to recognize the usb AE550. When I plug the usb cable in I see this in syslog: Feb 6 22:36:56 mythbox kernel: usb 1-1: new low speed USB device using
2006 May 07
3
Yet another HID device - Cyberpower AE550
Hope it's not too rude to just drop this here for y'all... Checking device (0764/0501) (001/005) - VendorID: 0764 - ProductID: 0501 - Manufacturer: CPS - Product: UPS AE550 - Serial Number: unknown This one and their 485 don't provide a load measurement -- the Windows drivers kick it onto battery for a timed period and measure the drain to guess the runtime -- apparently all their
2008 Jul 25
3
CyberPower 550SL reports LB and OB when on line power
I am using nut 2.2.2 and I have a CyberPower CP550SL. According to the drivers list, I should be using genericups with upstype set to 7, but when I try that and when I run upsc I get: driver.name: genericups driver.parameter.LB: 04 driver.parameter.pollinterval: 2 driver.parameter.port: /dev/ups driver.parameter.upstype: 7 driver.version: 2.2.2 driver.version.internal: 1.34 ups.mfr: CyberPower
2008 Jul 25
3
CyberPower 550SL reports LB and OB when on line power
I am using nut 2.2.2 and I have a CyberPower CP550SL. According to the drivers list, I should be using genericups with upstype set to 7, but when I try that and when I run upsc I get: driver.name: genericups driver.parameter.LB: 04 driver.parameter.pollinterval: 2 driver.parameter.port: /dev/ups driver.parameter.upstype: 7 driver.version: 2.2.2 driver.version.internal: 1.34 ups.mfr: CyberPower
2015 Aug 19
4
Need help with Tripp Lite SMART1300LCDT NUT v2.7.3
Here are couple of things I tried. 1) Changed the USB cable. Same problem 2) I put an old CyberPower CP550SL w/USB&SERIAL and it recognize it right away via the USB port I don?t know if that will give you any insight or eliminate certain things with the Tripp Lite SMART1300LCDT or not. Sent from Mail for Windows 10 From: Charles Lepple Sent: Tuesday, August 18, 2015 6:37 PM To: Johnny
2015 Aug 25
2
Need help with Tripp Lite SMART1300LCDT NUT v2.7.3
On Aug 19, 2015, at 9:00 AM, Charles Lepple <clepple at gmail.com> wrote: > > On Aug 19, 2015, at 12:08 AM, Johnny Wong <e430benz98 at yahoo.com> wrote: >> >> Here are couple of things I tried. >> >> 1) Changed the USB cable. Same problem >> 2) I put an old CyberPower CP550SL w/USB&SERIAL and it recognize it right away via the USB
2006 May 09
1
Fw: Yet another HID device - Cyberpower AE550
Peter Selinger wrote, > Hi Joe, > > I read between the lines that (a) you are using the newhidups driver, > and (b) it is working. Is this correct? You might want to post the > output of "upsc" just for the record. Whups, I should've been more clear and less terse -- it's been a long weekend putting the machines these are supporting into production! This
2015 Aug 21
1
Need help with Tripp Lite SMART1300LCDT NUT v2.7.3
I have gotten the links to the ./configure for NUT for NAS4Free see nas4free build makefile http://sourceforge.net/p/nas4free/code/ ... t/Makefile config files: http://sourceforge.net/p/nas4free/code/ ... nut/files/ I hope this give some insights On Wednesday, August 19, 2015 6:00 AM, Charles Lepple <clepple at gmail.com> wrote: On Aug 19, 2015, at 12:08 AM, Johnny Wong
2007 Nov 04
1
Nitram driver and timeout
Hi, I recently bought a Nitram Elite 2005 UPS and i installed nut to monitor it. Unfortunatly, i often have timeout errors (20 timeout per days): Broadcast Message from aurelien at berkelium (no tty) at 18:05 CET... Communications with UPS Nitram at localhost lost Broadcast Message from aurelien at berkelium (no tty) at 18:05 CET... Communications with UPS Nitram(AT)localhost
2007 Nov 04
1
Nitram driver and timeout
Hi, I recently bought a Nitram Elite 2005 UPS and i installed nut to monitor it. Unfortunatly, i often have timeout errors (20 timeout per days): Broadcast Message from aurelien at berkelium (no tty) at 18:05 CET... Communications with UPS Nitram at localhost lost Broadcast Message from aurelien at berkelium (no tty) at 18:05 CET... Communications with UPS Nitram(AT)localhost
2013 Mar 28
2
UPS don't reset
Debian sid package v. 2.6.4-2.3 UPS nitram elite 2002 700VA (serial port) MOBO A7V8X-X ================================ Hi list, Everything work fine, except after an AC supply shortage: the UPS don't come back to a normal behavior, it stays on battery (of course, it works right w/o any cable). Is there something I can do recover a normal behavior? JY -- Too much of a good thing is
2005 Oct 03
2
driver for Elite 2005 500VA
Hello, I've just finish a new driver for the Nitram UPS Elite 2005 500VA (compiled and tested with nut-2.0.1 and nut-2.1.0). Currently, all Nitram UPS are made by CyberPower, but the protocol is different than cyberpower.c. I don't have other model to test with, but I think this driver could monitor all Nitram 2005 UPS. I don't have the protocol specifications and thus some parts
2004 Apr 09
1
Sharp ZQ-290s sync software
Hi, Since Sharps communication protocols are "top secret", I'm trying to port their sync software to linux. I'm new to wine, so this might be silly, but after hours of googling and searching for solutions I'm posting this. After installing DCOM98.exe, the Desktop software installed, and it runs. Only problem is it doesn't detect the device connected to the serial port
2008 Jul 03
1
removing cpsups
I've just noticed that cpsups isn't listed anymore in driver.list. Any reason not have removed it from the source too? Still on the way to 2.4; any update on your confidence level to remove nitram and cyberpower too? -- Arnaud
2014 Jun 10
0
Unable to set up a "serial-over-USB" UPS (APC BZ2200BI-BR)
On 04/06/2014 at 09:44, Bruno Salvador <bruno.salvador at gmail.com> wrote: > What Douglas can do is to patch the solis executable in > /usr/local/libexec/nut/solis inside freenas, with the patches that I have > posted in the forum: Dear guys, Following your suggestions I was able to make NUT recognize my UPS model. Actually, the only modification I had to introduce in solis.c
2007 Apr 13
2
Problem with GeekSquad GS-1500 (Cyberpower 1500 avr lcd)
Hi, I've installed Nut 2.0.5 on a RedHat 9 box. I have a GeekSquad 1500 UPS. (GeekSquad is a BestBuy brand) I've found out that it's actually a CyberPower 1500 AVR LCD. I'm using it with the serial cable. I'm unable to get it working with any of the drivers provided with NUT. I've tried cpsups, cyberpower and powerpanel. here's the output of the different drivers
2016 May 31
2
[PATCH 4/4] drm/nouveau/acpi: fix lockup with PCIe runtime PM
On Mon, May 30, 2016 at 06:13:51PM +0200, Peter Wu wrote: > Do you have any suggestions for the case where the pcieport driver > refuses to put the bridge in D3 (because the BIOS is too old)? In that > case the nouveau driver needs to fallback to the DSM method (but not > when runtime PM is deliberately disabled by writing control=on). Do you know what Windows does then? I think we
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
Hello. Trouble to communicate with APC SmartUPS via serial port. UPS connected to the com1 port on windows host. Communication witch hyperterm works well. There is a log: YSM ^ASmart-UPS SC1000 n5S0713T63247 m03/29/07 L240.0 B27.10 apcupsd also can communicate with the UPS and works well. running apcsmart -a ups gives the following: com1: device reports different attributes than what were set