2012 Sep 19
1
New intermediate Windows binaries release - 2.6.5-3
?Hello, There is a new intermediate Windows binaries release available at : http://www.networkupstools.org/package/windows/NUT-Installer-2.6.5-3.msi This fixes a regression about stopping the NUT service. Feedback is highly appreciated. Regards, Fred -- Eaton Opensource Team - http://opensource.eaton.com ----------------------------- -----------------------------
2012 Sep 11
1
Back UPS ES and data stale with disconnected device
Hello NUT Team! I continue playing with NUT for Windows and USBHID-UPS driver I've got from Frederic to fix "Data Stale" problem. It seems there is something wrong when Network UPS Tools service is starting with disconnected USB cable. UPSMON is writing "Data Stale" to output and continue do it infinitely, even the cable is connected back. Here is a short log: Network
2017 Apr 03
4
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
On 03/04/17 17.24, Roger Price wrote: > On Mon, 3 Apr 2017, Jon Bendtsen wrote: > >> On 03/04/17 17.10, Roger Price wrote: >>> On Mon, 3 Apr 2017, Jon Bendtsen wrote: >>> >>>> Power seem to be lost immediately. >>>> But my APC Smart-UPS 1500 always reported everything OK. >>>> battery.charge : 100 >>> ...
2017 Sep 16
3
Flatpak request
I am using NUT on Linux Mint with no issues. Installed from PPA. However I have tried on 3 occasions to build from source for Solus 3 and have had no luck. Is there a possibility of NUT being built into a Flatpak so all distributions can use it. If it was available on Flathub it would be a simple and foolproof way of installing it. Many thanks for a great application.
2017 Apr 03
4
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
Hi debian jessie, nut 2.7.2-4 APC Smart-UPS 1500 connected through USB, running nut driver usbhid-ups This UPS powers my switches, internet connection and my monitor server that monitors this and my other UPSes + runs smokeping and nagios. But recently a powerloss seemed to have shutdown my monitor PC immediately, so it did not shut down the other servers cleanly. Power seem to be lost
2011 Apr 28
1
Problem with blazer_ser/megatec when upgrading to 2.6.0 from 2.4
Hello First things first, thanks for great work with NUT. For years I used Informer compact 3kVA UPS http://www.informups.com/informer_compact.html with nut/megatec serial driver, but it stopped working when I switched to blazer_ser with 2.6.0 upgrade. I'm using 2.6.0 on gentoo. Blazer_ser seems to connect with UPS, but upsmon reports driver not connected. uname -a Linux localhost
2012 Sep 13
2
Early shutdowns and 2.6.5-1 package for Windows
Hello NUT Team! I am testing the early shutdowns in NUT 2.6.5-1 package for Windows (Windows 7 x64). My configuration files: upsmon.conf RUN_AS_USER upsmon MONITOR upsa at 192.168.10.200 1 upsmon pass master MINSUPPLIES 1 SHUTDOWNCMD "/sbin/shutdown -h +0" NOTIFYCMD "upssched.exe" POLLFREQ 5 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME 15 POWERDOWNFLAG
2012 Apr 16
2
Snmp-ups/netvision driver for Socomec UPS
Hello We have an Socomec Sicon Netys PR3000 UPS equipped with NetVision Web/SNMP adaptor. I try to monitor the ups using snmp-ups driver and netvision mibs set. The snmp-ups driver starts correctly and connects to the UPS, upsd confirms it, but upsmon constantly shows "No communication" error I think the cause is the SNMP adapter reports the UPS status as "ECO mode"
2016 Aug 05
1
NUT UPS Slave Not Shutting Down
Hello All, I'm trying to establish a MASTER SLAVE configuration of UPS using NUT Driver. I'm able to shutdown the master after UPS is on BATTERY ( POWER BLACKOUT) .However I'm trying to shutdown the other SLAVE MACHINES BEFORE MASTER. But at the remote side ( Slaves ) shutdown after UPS blackout does not happen. My configuration in Master are /usr/etc/upsd.users
2011 Jan 13
1
SSL certificate verification with OpenSSL in NUT trunk
Hi all, After client's certificate verifications discussion in the mailing-list, I have done some tests with nut trunk and - if my config is not too bad - I think ther is a bug with server certificate verification. With a clean trunk checkout, compile and installation; and with the following config : upsmon.conf: CERTPATH /usr/local/ups/etc/cert/ CERTVERIFY 1 FORCESSL 1 Upsd.conf: CERTFILE
2012 Aug 30
1
Data stale and Back UPS ES
Hello! I tried NUT 2.6.5-1 (Windows port) with my APC Back UPS ES. It seems I have configured NUT properly, nut-scanner found my UPS: [nutdev1] driver = "usbhid-ups" port = "auto" vendorid = "051D" productid = "0002" product = "Back-UPS ES 525 FW:851.t3.I USB FW:t3" serial = "8B0745R23575
2014 Oct 01
2
Socomec ITYS 3000 + Netvision upsmon output
Hi, I have UPS Socomec ITYS 3000 with Netvision card. OS is Centos 6.5 64-bit. NUT installed with yum,. nut-2.6.5-2.el6.x86_64 nut-client-2.6.5-2.el6.x86_64 Why is ups.status empty? Here is upsc output: upsc myups at localhost battery.charge: 97.00 battery.runtime: -60.00 battery.voltage: -0.10 device.mfr: Net Vision v6.01 (SN 0101414290) device.model: ITYS 3 kVA device.serial: 3I14450043
2019 Jun 08
2
How to shutdown macOS / mac OSX from Network UPS Tools client - NUT
Hi, I’ve posted my question on Superuser.com but not had any replies in 2 weeks, so I guess no-one there knows anything about NUT. https://superuser.com/questions/1441153/how-to-shutdown-macos-mac-osx-from-network-ups-tools-client-nut <https://superuser.com/questions/1441153/how-to-shutdown-macos-mac-osx-from-network-ups-tools-client-nut> I’m looking for help in shutting down my iMac on
2020 Jan 26
1
Timer doesn't appear to start
I have a Raspberry PI that I have connected to a Deltec UPS via serial (upscode2 driver). I had an older version of Rasbian running. The nut configuration worked fine but I had mail issues I couldn't resolve when gmail changed how it handled MTAs. Plus it was running an old version of Deb that is no longer supported. It was broken enough I could not upgrade to a never version so I started from
2019 Jul 18
2
Another New User Question - Notify Script Not Running
2006 Jan 04
1
Nut 2.0.1, net-snmp-5.1.2p2, APC SUA1000 with AP9606: repeated comm lost/established messages
Hello list members, I am running NUT 2.0.1 on an OpenBSD 3.8 system, using the OpenBSD port for net-snmp-5.1.2p2. The UPS is connected via an AP9606 Web/SNMP card with current firmware, and the LAN. All goes well for a long time, usually more than one month. Then the system starts spitting messages about losing communications with the UPS. A second message about reconnecting follows immediately.
2017 Sep 17
4
building on Solus
Hi Charles, Thanks for your help. Seems to be mostly ok except am getting error access denied. See below. I see from searching this is a common error but so far I can't find a fix. This is how I configured things before make and install. created group nut nut:x:103: created system user ups with group nut. ups:x:123:103::/home/ups:/bin/bash Create statepath directory. sudo mkdir -p
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
Dear Ladies and Gentlemen, I have several old, yet functioning APC Smart-UPS (Model 600LS, Part AP600I, Firmware 6JI, no EEPROM, from 1991). They are not supported by Powerchute any more. I run NUT 2.6.5-4 on Windows XP SP3. I use COM1 port with cable 940-0024C. The connection fails with APC Smart protocol driver 3.0 (2.6.3-3534:3540M), APC command table version 3.0 or higher - it works with APC
2007 Aug 28
1
deadagi and billsec or answeredtime
Hello, I want to create php rate script and I'm using Deadagi. But I allways get billsec 0 , or nothing. Can you help me to solve this problem... My extension.conf: exten => _123,1,DeadAgi(rate.php) exten => _123,2,hangup And my simple test php script rate.php #!/usr/local/bin/php -q <?php include_once (dirname(__FILE__)."/phpagi.php"); $AGI = new AGI();
2011 Jul 19
2
KIN-1500AP RM + Windows 2008 64-bit Standard R2 SP1 (nut 2.6.1)
I have only RS-232 on the box (meanwhile, it was manufactured on march of 2011) Here is my configs: nut.conf: * * MODE = netserver ups.conf: * * [KIN1500] driver = powercom port = notUsed desc = "Powercom KING PRO KIN-1500AP RM" upsd.conf: * * LISTEN 192.168.1.2 3493 upsd.users: * * [monuser] password = xxxxxxxx upsmon master