Displaying 20 results from an estimated 4000 matches similar to: "APC Smart UPS 3000 LCD & Eaton Evolution S 3000"
2010 Oct 08
0
Updates to the Belkin driver
After installing NUT, I've noticed that the belkin driver capabilities
are rather basic. We have a Belkin Regulator Pro 1400VA (F6C1400-EUR),
so I've updated the driver to support control of the buzzer & tests, as
well as adding test result reporting.
I've attached the following patches. Hopefully they can be added to any
upcoming versions.
--
John Bayly
Systems Administrator
2010 Feb 10
2
APC Smart-UPS 3000XL: Compatible/Any good?
Hello list.
I'm contemplating buying new batteries and putting an older APC
Smart-UPS 3000XL back into service. Would that work well with NUT? Any
drawbacks to consider?
Thank you,
Tobias
--
Tobias Balle-Petersen
Kontrapunkt Group / System Administrator
2005 Aug 09
0
How to lower float charge voltage of an APC Smart UPS - corrected
My first posting had typos. Here is the corrected version:
You can lower the float charge voltage that APC Smart UPS units such as
SU1000NET or SU700NET supply to the battery. This is important to prevent
overcharging when when substituting Lead Acid Deep Cycle batteries for
the usual sealed maintenance free batteries provided. Instructions:
1) Only do this if you're fully trained and
2005 Aug 09
0
How to lower float charge voltage of an APC Smart UPS unit
You can lower the float charge voltage that APC Smart UPS units such as
SU1000NET or SU700NET supply to the battery. This is important when
substituting Lead Acid Deep Cycle batteries for the usual sealed maintenance
free batteries provided. Here are the instructions:
1) Only do this if you are fully trained and qualified to work on Lead Acid
powered UPS. These units contain lethal voltages
2013 Sep 17
0
Support for APC Smart-UPS X 3000
Just my experiences speaking, look at another brand. I use MGE/Eaton and
have had much better life and the quality has been much better. APC does
not release the protocol for comunicating with the UPS and so to get NUT to
work you have to sniff the traffic and then figure out what the commands
and responses mean.(thus reverse engineered) APC also will change the
protocol between models. (Thus why
2014 Oct 19
1
Smart-UPS RT 3000 XL: very old or unknown APC model, support will be limited
I have a Smart-UPS RT 3000 XL connected via serial cable to TrueNAS TrueNAS-9.2.1.2-RELEASE-x64 (002022c) which runs on FreeBSD 9.2-RELEASE-p3.
When I start the NUT service, I get the message:
Oct 20 01:53:50 truenas notifier: very old or unknown APC model, support will be limited
Which I interpret as an indicator of less than optimal operating mode. I suspect that the model identifier is not
2005 Oct 04
0
Problems connecting to APC/Smart-UPS 3000 RM
Hi all,
I have an APC/Smart-UPS 3000 RM that I am trying to connect to nut via the usb
port. I have nut running just fine on several other machines using APC ups's
via the serial ports but this usb thing is making me crazy.
If I do a "/sbin/newhidups -u root -D -a PS1" it recgonizes the ups and dumps
a bunch of information like below:
(porky pts12) # /sbin/newhidups -u root -D -D
2013 Sep 17
4
Support for APC Smart-UPS X 3000
Hi all,
I am completely new to NUT and setting up a UPS shut down in Linux. I am
looking at buying a APC Smart-UPS X 3000. When I look this device up in
the compatibility list this specific model is not listed, only a generic
entry for "Smart-UPS". It says to use the *apcsmart* driver. The
legend shows this as "protocol based on reverse engineering". What does
this
2008 Feb 25
0
APC Back-UPS XS 1500 LCD support (was: New supported UPS for your list)
Hi Chad,
Thanks for your report.
Everything seems fine, apart from the battery.date (2052/00/36), which
vaguely recall me something...
I've added this info to the Testing and trunk driver.list
Arnaud
--
Please note my new email address: arnaudquette at eaton.com
--
Linux / Unix Expert R&D - MGE Office Protection Systems -
http://www.mgeops.com
Network UPS Tools (NUT) Project Leader -
2012 Feb 02
2
APC SmartUPS 3000VA LCD not connecting
We recently had to replace an old APC SmartUPS 3000 with a newer 3000VA
(the 2U one). It has both serial and USB in the back (with an RJ-45 on
the end of the serial cable).
I can't get the apcsmart driver to connect. I figured it should work
the exact same as the old UPS, with /dev/ttyS0 as the port (I'm using
the same port on the server that the last one was plugged into). I even
2014 Jan 14
0
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
On 2014-01-14 10:12, dstrr wrote:
> Hello.
> Trouble to communicate with APC SmartUPS via serial port.
> UPS connected to the com1 port on windows host.
> Communication witch hyperterm works well.
> There is a log:
>
> YSM
> ^ASmart-UPS SC1000
> n5S0713T63247
> m03/29/07
> L240.0
> B27.10
>
> apcupsd also can communicate with the UPS and works well.
>
2012 Feb 21
1
eaton evolution not shutting down
Hi all,
I just changed my old MGE ellipse for a evolution 850 (now eaton). I can
connect using mge-shut (newmge-shut doesn't work). But I have a few
issues. I lloked around on NUT web-site and googled with no luck.
Using debian lenny on 2.6.18 kernel (due to some ISDN driver that
doesn't work with earlier kernels)
1) the most annoying is that I cannot shutdown the UPS. here is a trace :
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
Hello.
Trouble to communicate with APC SmartUPS via serial port.
UPS connected to the com1 port on windows host.
Communication witch hyperterm works well.
There is a log:
YSM
^ASmart-UPS SC1000
n5S0713T63247
m03/29/07
L240.0
B27.10
apcupsd also can communicate with the UPS and works well.
running apcsmart -a ups gives the following:
com1: device reports different attributes than what were set
2012 Aug 30
1
APC Smart UPS C1000
Has anyone been able to get an APC Smart UPS C1000 to work with NUT on pfSense? I can't figure it out.
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120830/d1f5b864/attachment.html>
2008 Jan 15
1
How to lower float charge voltage of an APC Smart UPS
Dear Sir,
Please tell me if u have any method to increase the charging current of
APC smart 1000/1400VA with and without external battery bank option. I
am using externally 40 and 80 Amp lead acid batteries but charging time
is too long. Please help me ASAP.
Regards,
Afzaal Ahmad
UPS Engineer
afzaal.ahmad at sbp.org.pk
-------------- next part --------------
An HTML
2009 May 25
1
APC Smart UPS 900i
Hi,
I'm running an old APC Smart UPS 900i. As there isn't any software from APC which supports this
UPS anymore, I've installed NUT (Gentoo Ebuilds), but version 2.0.5 and version 2.2.2 loose
connection to the UPS while version 2.4.1 and SVN version don't show any settings and there are no
instant commands.
The only information I can get are:
driver.name: apcsmart
2010 Feb 02
0
Was, Re: APC Smart-ups "status codes" (slightly OT), is replacement batteries
>
> On Fri, 2010-01-29 at 16:53 -0500, m.roth at 5-cent.us wrote:
<battery change tale o' woe snipped>
>> But the idiot light's still on.
<snip>
Well, I followed the link to the NUT info, and tried a "manual"
calibration, and still no joy. Swapping in a cartridge that's still good,
the light goes out, so it's not the unit.
However, googling for
2006 Feb 03
1
APC Smart-UPS 1000 RM USB problems with newhidups
I'm trying to use a rackmount Smart-UPS from APC with the USB connector, and
I'm running into some issues. They seem to stem from the fact that the
Report Descriptor is much larger than any other UPS I've seen (61939 bytes).
Here is the quick fix that I put in libusb.c after getting the HID
descriptor, and before getting the Report descriptor, which seems to work
okay:
2006 Apr 21
1
APC Smart-UPS 1000RM issues with newhidups
Peter, if you're back, I was wondering if you might have a chance to look
into the issues I reported last month. I'm back to using hidups right now,
but I would prefer to use a current, maintained driver. Thanks!
2006 Feb 05
1
APC Smart-UPS v/s 650 variables.
Hi all,
when I try to get infos from this ups, the only variables that upsc
print is:
# upsc Smart-UPS@localhost
driver.name: apcsmart
driver.version: 2.0.0
driver.version.internal: 1.99.6
ups.mfr: APC
ups.status: OL
Is it not possible to get voltage and other infos from that model of
UPS? Thanks.
Regards,
Dio.