Displaying 20 results from an estimated 9000 matches similar to: "using asterisk to do remote control"
2005 Feb 20
0
Re: Asterisk-Users Digest, Vol 7, Issue 260
> From: "James Bean" <james@hdcs.com.au>
> Has anyone every setup an external open/close relay, off say a serial
> interface, and have an extension trigger the relay?
The following will do the trick. Just add a 5vdc solid state relay
('cause you can't sink too much current out of the RS232C port).
Substitute "2", "4" or "6" in the
2004 Dec 20
2
Is there hardware to remote control
> From: Ronald Wiplinger <ronald@elmit.com>
> Subject: [Asterisk-Users] Is there hardware to remote control
> available?
> To: Asterisk Users Mailing List - Non-Commercial Discussion
> <asterisk-users@lists.digium.com>
> Message-ID: <41C6D43F.5070201@elmit.com>
> Content-Type: text/plain; charset=us-ascii; format=flowed
>
> I am looking for a
2011 Apr 13
1
Fwd: Re: Asterisk as a Condo door opener/intercom
Asterisk as a phone system makes perfect sense in a condo. You can get
all the DID's you want and eliminate costs for the owners. You can offer
standard FXO for people who don't care and IP sets for people who want
to "upgrade" to feature sets.
Your door openner is a piece of cake.
1. Create an option in your dialplan only in the "from-access-door"
context that reads
2008 Mar 14
0
Sola 305 with INT-0051 cable
Hello again,
I have a Sola 305 (aka Powerware 3110) here connected via a serial
INT-0051 cable which I am trying to get working with nut. The
driver.list file indicates that nut supports the Sola 305 when connected
via the INT-0025C cable using the genericups driver with upstype set to
7 but it does not mention the INT-0051.
I was able to use the "Basic CheckUPS II" utility provided
2005 Aug 08
1
Here are CORRECT APC cable diagrams
+-----------------------------------------------------------------+
| |
| Black APC 940-0024C Smart Signalling UPS Cable Wiring Diagram |
| This information is verified and tested to be 100% correct. |
| |
2004 Aug 13
2
Lost 7960 time display on upgrade
I upgraded my 7960 to sip v 6.3 and my display time has now disappeared
from the top left corner.
Loadid: SW: P0S3-06-3-00 ARM: PAS3ARM1 Boot: PC03M030 DSP: PS03AT38
Here is the section dealing with time in my SIPDefault.cnf file. Does
anybody see anything wrong with it or have any other ideas?
# Time Server (There are multiple values and configurations refer to
Admin Guide for Specifics)
2006 Apr 13
4
OT: MWI on Treo 600/650
My cell vm goes to asterisk, not the carrier. Apparently MWI is turned
on/off with specially formatted SMS messages. Anyone know how to do this
on a Treo 600? Having the phone light from Asterisk would be HUGE ...
not to mention extremely cool.
dbc.
2015 Nov 21
2
Contact-closure UPS
>> On Nov 21, 2015, at 2:43 AM, R?bert SZAKSZ <robert at szaksz.eu> wrote:
>>
>> I mesured it and on DC and it shows 0 V (zero V).
>> May be the information (pls. see attachment) that UPS PIN1 should bee keept HI is mandatory. Should I connect it to PC PIN4 DTR?
>
>Certainly possible. blazer_ser and nutdrv_qx should set DTR high and RTS low by default, but
2006 Jul 11
1
Re: [nut-commits] svn commit r446 - in branches/Testing: . drivers man
> +22 = Gamatronic UPSs with alarm interface
> + [CP=RTS] [OL=CTS] [LB=\-DCD] [SD=DTR]
> +
> +22 = CyberPower SL seriess
> + [CP=RTS] [OL=CTS] [LB=\-CAR] [SD=DTR]
> +
> +
This part of the patch is no good. While TIOCM_CAR is equivalent to
TIOCM_CD (at least in some implementations) CAR certainly isn't handled
the same as DCD by genericups. It won't be
2005 Jan 10
1
Re: Toronto
It looks like this meetup group is becoming the venue for contact as
most "Toronto" respondents have signed up here. Can I request that the
remainder who responded to the "Toronto" call signup?
Shidan is the organizer and has proposed a date. I'd hate to confirm it
without the remainder having input - especially those with travel times
like Andrew K. out in Listowel.
2005 Oct 03
1
CyberPower SL-series
This code, added to drivers/genericups.h, supports the CyberPower SL
series UPSes. I've tested with my 725SL - the online/on battery
transition, and low battery status, and finally the shutdown signal all
work as expected.
*** genericups.h.orig Sun Nov 2 16:54:24 2003
--- genericups.h Mon Oct 3 13:49:00 2005
***************
*** 220,225 ****
--- 220,234 ----
TIOCM_ST
2006 Feb 04
1
Old Contact UPS Info
I tried to find a search button for the mailing list but could not. So rtfm
me with the link please.
If not..
I have an old Deltec PowerRite Pro 2 UPS which has a 9 pin serial cable.
By trial and error Im pretty sure I found LB = DCD, but can not get the
combination for OB / OL. No matter what I do I get the results below.
driver.name: genericups
driver.parameter.CP: CTS
driver.parameter.LB:
2006 Aug 08
1
GSM back door to shell with Centos and Palm handhelds
Hi folks,
Don't know if it could be interesting or not, even useful, but past days
i was spending my time trying to use an old gsm motorola v150 mobile
phone to get access to my host from my palm device with pssh
(http://www.sealiesoftware.com/pssh/), these are the steps i did to
accomplish it, feel free to suggest or improve it, anyway i found it
usefull.
First, this motorolla has an usb
2019 Nov 01
0
Request to Document obscure SERIAL flowcontrol setting
Hi:
I took me a while to figure this out, so I thought it might be good to document
on the wiki.
When using Syslinux's SERIAL option (
https://wiki.syslinux.org/wiki/index.php?title=SYSLINUX#SERIAL_port_.5Bbaudrate_.5Bflowcontrol.5D.5D
) in conjunction with Serial over LAN (
https://en.wikipedia.org/wiki/Serial_over_LAN), there is no "CTS assertion" (at
least with some BIOS), but
2005 Aug 24
6
Cisco 7960 / SIP & tftp configs
I have three questions about my 7960 phone that I can't discern from the
docs/wiki.
1st - If I change the SIPxxxxxx.cnf file to change registrations it sets
up new lines as expected. If I delete a line it doesn't get removed when
I reboot the phone. I have to go to the phone, unlock it, and reset the
SIP parameters. How do I make it "forget" what it has programmed and
2007 Mar 27
1
Re: asterisk-users Digest, Vol 32, Issue 106
> Lito Lampitoc wrote:
> > thanks for enlightening. So you mean, if I have 3 lines when the
> caller
> > dialled the first line and it was busy, the call will be diverted
> to the
> > next two available lines in random?
> >
>
> I don't think it's random. I think its just sequential. If main
> line
> is busy, try second. If that is
2010 Jun 15
0
mercury smart1200 pro serial powerdown problem
Hello *
Trying to get above serial UPS to work gives my some troubles.
With upstype=21 [CP=RTS] [OL=CTS] [LB=-DCD] [SD=RTS+DTR]
and/or upstype=4 [CP=RTS] [OL=CTS] [LB=-DCD] [SD=-RTS]
I do get OL OB LB ok, but shutting down the UPS does not work.
Direct call w/ command genericups ... -k and from lowbatt/
initscripts doesnt do. The UPS claims to be capable of and
the software shipped (RUPS2000)
2005 Nov 30
4
ups.conf configure
Hello, I got this information from the manufacturer of my ups Kobian/Mercury
and were tested wtih powstatd on Linux (Works OK). Now i want to configure
it with NUT and i didn't have any luck (it always says OB)
Initiliasation for monitoring: RTS = 1 (High)
Main power fail: CTS = 0 (Low)
Batter low: DCD = 0 (Low)
Kill UPS: DTR = 0 (Low)
How would the ups.conf look like?
Reagards,
Lep
2015 Nov 16
2
Contact-closure UPS
Hello,
I have one UPS Infosec XP Pro 2500 RM and it works with windows sw RUPS2000.
Now I want to install this UPS as virtual server on vmware ESXi vMA - (SUSE SLES 11SP2 linux).
On this linux I have NUT 2.6.0 and I stopped now with configuration of genericups driver.
Working cable (direct cable pin1-pin1 ... pin9-pin9) connection on Windows:
PIN | PC | UPS
2004 Oct 08
5
SPA3000 as a replacement for X100P
I am still haveing problems (echo) with my X100P but I'm thinking it has
more to do with the server it is in which is not a negotiable item at
this time. My question then is to the use of SPA3000's as a replacement
from the FXO standpoint.
1. Can you setup the FXO port to recognize distinctinve ring and call a
different context like you can do with Zap channels? Being able to call
a