similar to: Display Name

Displaying 20 results from an estimated 2000 matches similar to: "Display Name"

2006 Jun 15
6
Comedian Mail not deleting .txt file
I have had two users on two separate systems indicate that they could "not hear a new message" When I investigate I find that the user has marked a message for deletion. The .WAV .wav and gsm files are gone but the .txt file remains thus giving asterisk and the user the impression that a new message exists when it does not. Has anyone else encountered this issue? Is there a fix?
2004 Sep 24
2
What type of PRI setup is best
I am having my colo set up 2 PRI's for my new asterisk implementation. They asked the following... ##SNIP## What type (NI2, NTI, 4ESS, or 5ESS) and whether they want to be USER or NETWORK. If the equipment is flexible, NI2, with us as NETWORK is preferred. ##SNIP## We are using a digium quad span T1 card. What is the recommended setup? Thanks, Chris
2005 Jun 10
3
DMS-500 CID name not in CDR
Hi Guys, I have several * servers connected to T1 PRI's from various service providers in multiple locations the US. All the * servers use the same hardware with the same OS and * version. When connected to 5ESS Switches, using the NI2 (national) PRI protocol, the CID name and number come across fine and populate into the * CDR fine. I connected to a DMS-500, NI2 (national) protocol and
2004 Nov 29
1
New T100P Pri install suggestions?
In the next week or so, we'll be turning up a new T1 Pri from Cox Cable in Omaha using a T100P (installed but not yet configured). While discussing the interface parameters with a very knowledgable Cox engineer, we decided on some of the basics including b8zs, esf, dchan=24, callerid, 5 digits of called number forwarded to *, and switchtype=national (NI2). They indicated their CO switch is a
2003 Nov 10
2
ISDN TBCT....
Greetings, This may be a bit arcane but does anyone know what the contents of a facility message should be for initiating a TBCT on an NI2 ISDN. I've been trying to get it to work on a DMS100 for the last four months to no avail. The message I am currently sending makes it to the switch but is returned with unknown message. Perhaps someone here has done it before and can help me out.
2005 May 13
5
Is there a product to simulate a PRI trunk?
Does anyone know of a way to simulate the signaling of a PRI trunk for testing/setup purposes? I realize this may be a rather naive question, but I was wondering if you could take a TE110, for example, and using a crossover cable (or not?) and some means of emulating the NI2 signaling protocol connect it to another TE110 on another machine to test and verify an installation before the telco
2005 Jun 14
2
[PRI] TE110P
We are in the process of installing a PRI line and we are going to connect it to an Asterisk Box. Verizon called us today to find out some information. I am surprised that they have never heard of Asterisk or Digium. But anyways, they needed some information in order to set up the circuit. Does the TE110P support NI1 or NI2? (I think the answer is both) What is the number of digits
2009 Mar 27
1
General help for a function I'm attempting to write
Hello, I have written a small function ('JostD' based upon a recent molecular ecology paper) to calculate genetic distance between populations (columns in my data set). As I have it now I have to tell it which 2 columns to use (X, Y). I would like it to automatically calculate 'JostD' for all combinations of columns, perhaps returning a matrix of distances. Thanks for any help
2007 Aug 21
2
compatibility of PRI Two B channel transfers TBTC/2BTC
Hello, A client has asked for Two B channel Transfer capability (known as TBCT or 2BCT, similar to other features such as ECT, RTL and Q,SIG Path Replacement) in a new Asterisk system and so I researched the capability and came up with quite a few gaps in documentation.
2005 Aug 09
3
First PRI
Hello All, I am getting my first PRI installed in a couple of weeks and I wanted to ask for a little advice. I have a single span Digium card I will be using for the install. Id there a benefit to which protocol I use? When asked, I told them to set it up as NI2. The PRI is through MCI and will be used for local and long distance with DIDs and features like CallerID, etc. Any advice would be
2011 Mar 25
6
Back-to-back asterisk PRI issue
Following is my scenario to connect back to back PRI of two asterisk server. PRI cards are Sangoma A102D [Asterisk1]------------[PRI]-Cross Cable---------[Asterisk2] Asterisk1 ; Span 1 (MASTER) switchtype = national ; commonly referred to as NI2 context = from-pstn group = 0,24 echocancel = yes signalling = pri_net channel => 1-23 Asterisk2 ; Span 1 switchtype = national ; commonly
2007 Jul 12
0
No subject
Although in a bugtracker posting with a patch from over two years ago, Matt Fredrickson from Digium says that it works with 5ESS under Asterisk 1.2.X: http://bugs.digium.com/view.php?id=3554 There are also bounties and claims of this feature working on NI2 protocol(although no patches posted) on the voip-info.org Wiki:
2005 Feb 18
1
Send CallerID to PBX via PRI NI2
I am terminating a PRI, NI2 signaling into a PBX (My company's PBX not the PSTN) from an Asterisk server. Caller ID number appears to be transmitted caller id name is not being transmitted is their a compile time flag on libpri that I need to un-comment to enable this feature or is this is unsupported for now? Thanks Chris. -------------- next part -------------- An HTML attachment
2007 Aug 01
5
pri "call by call" trunking?
I've been working with a telco for the past two days trying to get a PRI span up and running. This is a small-ish telco and I get the feeling they don't do this very often. Anyway, they specified a pretty standard setup: ni2 switchtype, esf framing, b8zs coding, etc. All of my b-channels are up, but we're having a heck of a time getting the d-channel to come up. He finds out that
2006 Apr 18
6
T1 to cross connect remote PBX and asterisk
Looking for someone with a successful experience similar to this; I have a need to cross connect a 3COM NBX PBX PRI interface to asterisk, but over a long distance. We do not need any IP connectivity and the solution requires G.711u audio so there is no benefit to using IP. Has anyone here successfully cross connected any PBX PRI interface expecting NI2 PRI signaling B8ZS/ESF with an
2005 Jun 22
0
DMS-500 CID NAME Problem
Hi All, Sorry for the double post, but I'm in a real bind. I have several * servers connected to T1 PRI's from various service providers in multiple locations the US. All the * servers use the same hardware with the same OS and * version CVS-v1-0-11/09/04-12:27:27. When connected to 5ESS Switches, using the NI2 (national) PRI protocol, the CID name and number come across fine and
2006 Mar 22
3
PRI DMS100 -> Nortel Meridian Option 81
Hello all, I have Asterisk 1.2.1 and a TE110P connected to a Nortel Meridian Option 81C system. The PRI line is currently setup as DMS100. Here are the relevant lines from zaptel.conf and zapata.conf: zaptel.conf: span=1,1,0,esf,b8zs bchan=1-23 dchan=24 loadzone = us defaultzone = us zapata.conf: [channels] language=en context=from-internal musiconhold=default switchtype=dms100
2006 Jan 20
2
Asterisk bounty PRI 2B channel transfer for NI2 PRI line
Maintainer: Express Line Date opened: January 17, 2006 Status: Open Value of bounty: $5000.00 Licensing for code: We retain intellectual rights to the underlying source code. We need Asterisk (stable version) to be able to perform a 2B channel transfer for a NI2 B8ZS PRI line. We can't use a channelized T1 at the time for our work. This feature is commonly called a call transfer on analog
2006 Jun 08
6
revisit to legacy PBX and CID over PRI
My legacy PBX accepts CID number, but not name. My old PRI vendor never sent the name, so there was never an issue. I have wedged asterisk between the Legacy PBX and PSTN. PSTN - PRI - asterisk - PRI - Legacy. Any calls from asterisk (sip and iax extensions) which have callerID set, will not connect. The legacy PBX hangs up, but asterisk thinks that it is still ringing. I have added
2007 Aug 06
4
low-level dump for PRI dchan debugging
I've been going back and forth with my telco for several days, trying different configurations to get a new PRI to come up. The bchannels are all up and the T1 is not in alarm status. The dchannel refuses to come up however. We've tried ni2, qsig, and now dms100 for the switchtype. The telco tech I've been working with says that he's been sending "reset all channels"