similar to: Caller ID with NAME on PRI

Displaying 20 results from an estimated 10000 matches similar to: "Caller ID with NAME on PRI"

2005 Mar 01
3
Ordering a Voice PRI for Asterisk
We are in the process of ordering a Voice PRI to plug into Asterisk. Of course we will be buying a card from Digium for this. Question is this, there seem to be MANY options technically when ordering this PRI (in the US) but since this is the first time ordering a voice circuit I am clueless as to what options we need. Any clues would be helpful or maybe something has already been written
2005 May 13
5
Is there a product to simulate a PRI trunk?
Does anyone know of a way to simulate the signaling of a PRI trunk for testing/setup purposes? I realize this may be a rather naive question, but I was wondering if you could take a TE110, for example, and using a crossover cable (or not?) and some means of emulating the NI2 signaling protocol connect it to another TE110 on another machine to test and verify an installation before the telco
2004 Sep 24
2
What type of PRI setup is best
I am having my colo set up 2 PRI's for my new asterisk implementation. They asked the following... ##SNIP## What type (NI2, NTI, 4ESS, or 5ESS) and whether they want to be USER or NETWORK. If the equipment is flexible, NI2, with us as NETWORK is preferred. ##SNIP## We are using a digium quad span T1 card. What is the recommended setup? Thanks, Chris
2005 Feb 18
1
Send CallerID to PBX via PRI NI2
I am terminating a PRI, NI2 signaling into a PBX (My company's PBX not the PSTN) from an Asterisk server. Caller ID number appears to be transmitted caller id name is not being transmitted is their a compile time flag on libpri that I need to un-comment to enable this feature or is this is unsupported for now? Thanks Chris. -------------- next part -------------- An HTML attachment
2005 Feb 14
7
Outbound Caller ID on PRI
We have just had an ISDN PRI service commissioned here in AU (using Powertel as provider). I have called them and ensured that we have the ability to set Caller ID on our service to any number in our 100 number block, and I have been assured that everything is OK from their end (unlikely). Every time I drop a sample.call in to /var/spool/asterisk/outgoing with the Callerid: option set, the
2005 Aug 09
3
First PRI
Hello All, I am getting my first PRI installed in a couple of weeks and I wanted to ask for a little advice. I have a single span Digium card I will be using for the install. Id there a benefit to which protocol I use? When asked, I told them to set it up as NI2. The PRI is through MCI and will be used for local and long distance with DIDs and features like CallerID, etc. Any advice would be
2004 Nov 29
1
New T100P Pri install suggestions?
In the next week or so, we'll be turning up a new T1 Pri from Cox Cable in Omaha using a T100P (installed but not yet configured). While discussing the interface parameters with a very knowledgable Cox engineer, we decided on some of the basics including b8zs, esf, dchan=24, callerid, 5 digits of called number forwarded to *, and switchtype=national (NI2). They indicated their CO switch is a
2011 Mar 25
6
Back-to-back asterisk PRI issue
Following is my scenario to connect back to back PRI of two asterisk server. PRI cards are Sangoma A102D [Asterisk1]------------[PRI]-Cross Cable---------[Asterisk2] Asterisk1 ; Span 1 (MASTER) switchtype = national ; commonly referred to as NI2 context = from-pstn group = 0,24 echocancel = yes signalling = pri_net channel => 1-23 Asterisk2 ; Span 1 switchtype = national ; commonly
2006 Jun 08
6
revisit to legacy PBX and CID over PRI
My legacy PBX accepts CID number, but not name. My old PRI vendor never sent the name, so there was never an issue. I have wedged asterisk between the Legacy PBX and PSTN. PSTN - PRI - asterisk - PRI - Legacy. Any calls from asterisk (sip and iax extensions) which have callerID set, will not connect. The legacy PBX hangs up, but asterisk thinks that it is still ringing. I have added
2004 Dec 15
2
No Caller ID Name PRI NI2.
Okay, now I am really confused. I have two PRI's coming in from two different Carriers (QWEST and ELI), both of them are supposed to be setup to pass name and number on incoming calls. Problem that I am having is that I am not receiving inbound caller id name on either PRI, the only thing that both carriers have in common is that I am terminating into a DMS switch at the carrier.
2006 Jan 20
2
Asterisk bounty PRI 2B channel transfer for NI2 PRI line
Maintainer: Express Line Date opened: January 17, 2006 Status: Open Value of bounty: $5000.00 Licensing for code: We retain intellectual rights to the underlying source code. We need Asterisk (stable version) to be able to perform a 2B channel transfer for a NI2 B8ZS PRI line. We can't use a channelized T1 at the time for our work. This feature is commonly called a call transfer on analog
2007 Aug 01
5
pri "call by call" trunking?
I've been working with a telco for the past two days trying to get a PRI span up and running. This is a small-ish telco and I get the feeling they don't do this very often. Anyway, they specified a pretty standard setup: ni2 switchtype, esf framing, b8zs coding, etc. All of my b-channels are up, but we're having a heck of a time getting the d-channel to come up. He finds out that
2003 May 22
3
nfas on T400P?
Can T400P be configured for nfas (one d-channel providing signaling for more than one span)? Thank you. Alex Zarubin -------------- next part -------------- An HTML attachment was scrubbed... URL: http://lists.digium.com/pipermail/asterisk-users/attachments/20030522/f2b637a9/attachment.htm
2004 Jan 05
3
DID Trunk Lines and Caller ID
I have an installation which is currenly using 14 DID Trunk Lines. I need to be able to use Caller ID information and currently it is not available on these lines. Is there another way to access this information? Thanks -------------- next part -------------- An HTML attachment was scrubbed... URL: http://lists.digium.com/pipermail/asterisk-users/attachments/20040105/62559e22/attachment.htm
2003 May 27
2
Caller-ID questions and suggestions
1. It would be very helpful if the voicemail module included the caller-ID info (name and number) in the "Subject" line. Otherwise, looking at the list of messages is like looking at an INBOX without a "From" column. I patched app_voicemail.c quickly, but it would be even better if this were a configuration option (since some installations don't have caller-ID
2007 Aug 06
4
low-level dump for PRI dchan debugging
I've been going back and forth with my telco for several days, trying different configurations to get a new PRI to come up. The bchannels are all up and the T1 is not in alarm status. The dchannel refuses to come up however. We've tried ni2, qsig, and now dms100 for the switchtype. The telco tech I've been working with says that he's been sending "reset all channels"
2006 Apr 18
6
T1 to cross connect remote PBX and asterisk
Looking for someone with a successful experience similar to this; I have a need to cross connect a 3COM NBX PBX PRI interface to asterisk, but over a long distance. We do not need any IP connectivity and the solution requires G.711u audio so there is no benefit to using IP. Has anyone here successfully cross connected any PBX PRI interface expecting NI2 PRI signaling B8ZS/ESF with an
2005 Jun 14
2
[PRI] TE110P
We are in the process of installing a PRI line and we are going to connect it to an Asterisk Box. Verizon called us today to find out some information. I am surprised that they have never heard of Asterisk or Digium. But anyways, they needed some information in order to set up the circuit. Does the TE110P support NI1 or NI2? (I think the answer is both) What is the number of digits
2009 Mar 27
1
General help for a function I'm attempting to write
Hello, I have written a small function ('JostD' based upon a recent molecular ecology paper) to calculate genetic distance between populations (columns in my data set). As I have it now I have to tell it which 2 columns to use (X, Y). I would like it to automatically calculate 'JostD' for all combinations of columns, perhaps returning a matrix of distances. Thanks for any help
2005 Jun 10
3
DMS-500 CID name not in CDR
Hi Guys, I have several * servers connected to T1 PRI's from various service providers in multiple locations the US. All the * servers use the same hardware with the same OS and * version. When connected to 5ESS Switches, using the NI2 (national) PRI protocol, the CID name and number come across fine and populate into the * CDR fine. I connected to a DMS-500, NI2 (national) protocol and