Displaying 20 results from an estimated 82 matches for "w32tm".
Did you mean:
w32
2024 Jan 18
1
Joining Windows 10 Domain Member to Samba AD/DC
...sing the DC for time sync
> even though that specific GPO was removed (all of the others cheerfully
> started using the DC) and I needed to reset the time service to get it to
> work as intended.
> Do this in an elevated prompt:
> ==========================
> net stop w32time
> w32tm /unregister
> w32tm /register
> net start w32time
> ==========================
>
> There was also a snag with the DC after the upgrade. I was following my own
> post from the past -
> https://lists.samba.org/archive/samba/2021-March/235228.html - but the DC
> was not acting...
2024 Jan 17
1
Joining Windows 10 Domain Member to Samba AD/DC
I have the impression your DC?s ntp server is not working properly for whatever reason. Your windows machines try to grab time for them, can?t, and then default to local coms clock or some other time source.
From a windows member machine, can you try :
w32tm /stripchart /computer:us.pool.ntp.org /dataonly /samples:5
That should work. Then try:
w32tm /stripchart /computer:your.dc.address /dataonly /samples:5
And see if you get a similar response.
On Jan 16, 2024 at 20:31 +0100, Mark Foley <mfoley at novatec-inc.com>, wrote:
>
> As I'v...
2024 Jan 17
1
Joining Windows 10 Domain Member to Samba AD/DC
...ts.samba.org>
>
> I have the impression your DC?s ntp server is not working properly for whatever reason. Your windows machines try to grab time for them, can?t, and then default to local coms clock or some other time source.
>
> From a windows member machine, can you try :
>
> w32tm /stripchart /computer:us.pool.ntp.org /dataonly /samples:5
>
> That should work. Then try:
>
> w32tm /stripchart /computer:your.dc.address /dataonly /samples:5
>
> And see if you get a similar response.
> On Jan 16, 2024 at 20:31 +0100, Mark Foley <mfoley at novatec-inc.com&...
2015 Apr 22
2
Time synchronization issue
...erver is correctly synchronized with NTP server.
>
> > I don't understand the reason of my problem, and don't know were to start
> > investigating.
>
> > Has anybody got this issue ?
>
> Got exactly your problem two days ago.
> From elevated shell:
>
> w32tm /unregister
> reboot
> w32tm /register
> w32tm /config /manualpeerlist:time.example.com /syncfromflags:MANUAL
> /update
> time /T (To test if synchronization done correctly)
>
> time.example.com is your domain time server - either AD DC or an NTP
> server it
> is synchron...
2018 Nov 22
2
NTP strangeness...
...UNNING
(STOPPABLE, NOT_PAUSABLE, ACCEPTS_SHUTDOWN)
CODICE_USCITA_WIN32 : 0 (0x0)
CODICE_USCITA_SERVIZIO : 0 (0x0)
PUNTO_CONTROLLO : 0x0
INDICAZIONE_ATTESA : 0x0
Windows is able to find NTP servers:
C:\Users\gaio>w32tm /monitor
È in corso il recupero dell'elenco dei controller di dominio Active Directory pe
vdc3t1.ad.fvg.lnf.it[10.99.21.1:123]:
ICMP: 16ms ritardo
NTP: +0.0175839s differenza di tempo dall'orologio locale
RefID: vdcud1.ad.fvg.lnf.it [10.99.1.3]
Strato: 4
vdcsv1.ad...
2015 Apr 24
1
Time synchronization issue
Hi !
Actually, problem was located on client side, not samba side.
w32time has "disappeared" from services list (!)
the
w32tm /unregister and w32tm /register
solve the problem
My clients seem to be correctly synchronised with my AD DC now.
If i find out why w32time has disappeared, I'll post a message here.
Thank you for your help !
2015-04-22 16:02 GMT+02:00 Andrey Repin <anrdaemon at yandex.ru>:
> Gre...
2024 Jan 05
2
Joining Windows 10 Domain Member to Samba AD/DC
...> I've created the Group Policy for the "Time Sources". This doesn't seem to be
> working. This did work fine with my old 4.8.2 DC, so I know it works in
> principle.
>
> I have additional notes and have tried (on the Windows member):
>
> net stop w32time
> w32tm /unregister
> w32tm /register
> net start w32time
>
> I've rebooted both the DC and the Windows member. On the Windows member I still
> get:
>
>> w32tm /query /source
> Local CMOS Clock
>
> whereas I expect the return to be "dc1.hprs.locl"
>
> I...
2020 Nov 18
6
Time sync not working with Windows 10
...'Date & Time settings > Sync Now' always gives "Time synchronization failed".
For Windows 7 workstations, several years ago, I followed the advice in
https://www.meinbergglobal.com/english/info/ntp-w32time.htm which was to do the following on
the Windows 7 workstations:
w32tm /config /manualpeerlist:mail,0x8 /syncfromflags:MANUAL
w32tm /config /update
Check the configuration:
w32tm /query /source
This worked and time was in-sync on the WIN7 computers for many years. I did this after
upgrading/installing each Windows 10 workstation during 2019 Q4 and 2020 Q1, but app...
2024 Jan 05
2
Joining Windows 10 Domain Member to Samba AD/DC
...the wikis would mention the GPO not being
> needed.
Did you see the section titles "Default Time Source" in the page you
link to that I quoted previously? The wiki clearly spells it out that
using a GPO is usually unnecessary.
> How do you know you're syncing with the DC?
'w32tm /query /status' will show you.
> What does your 'w32tm /query /source' give you?
My Windows domain members point to the DC.
Chris
2018 Nov 06
2
Time server on AD DC in an LXD container.
Further investigations reveal:
---
C:\WINDOWS\system32> w32tm /monitor
GetDcList failed with error code: 0x800706BA.
Exiting with error 0x800706BA
---
error 0x800706BA indicates that the RPC server is unavailable.
Any ideas?
Thanks,
Jonathan Kreider
On Tue, Nov 6, 2018 at 5:48 PM Jonathan Kreider <jonathan.kreider at gmail.com>
wrote:
>
> Th...
2005 Mar 18
0
using w32tm (WinXP) w/samba3 as DC: can't get DC List
...ssfully set the time by specifying the DC-hostname directly,
but the help text says internet synchronization only occurs _weekly_
(weakly?).
It says if you are part of a domain, your clock is automatically
synchronized with the PDC. But my computer doesn't appear to
be doing this. When I ask w32tm to compare it's local clock
to the "Domain's" network time:
> w32tm /monitor /domain:Bliss # I get:
GetDcList failed with error code: 0x80070774.
Exiting with error 0x80070774
---
In the system log, I see the following message:
Time Provider NtpClient: This machine i...
2018 Nov 22
0
NTP strangeness...
Hi Marco,
As far i can see here.
Are all your ADDC servers set to the same source NTP ( preffered a stratum 1 or 2 ) server. ( and not pool ntp sources )
Because below i see stratum 4 and stratum 3 servers and a timeout on one server.
When i look at this.
> C:\Users\gaio>w32tm /query /peers
> N. peer: 1
> Peer: vdcpp2.ad.fvg.lnf.it
> Stato: Attivo
> Tempo rimanente: 914.2880000s...
2024 Jan 05
1
Joining Windows 10 Domain Member to Samba AD/DC
...icy for the "Time Sources". This doesn't seem to be
> > working. This did work fine with my old 4.8.2 DC, so I know it works in
> > principle.
> >
> > I have additional notes and have tried (on the Windows member):
> >
> > net stop w32time
> > w32tm /unregister
> > w32tm /register
> > net start w32time
> >
> > I've rebooted both the DC and the Windows member. On the Windows member I still
> > get:
> >
> >> w32tm /query /source
> > Local CMOS Clock
> >
> > whereas I expect the r...
2020 Nov 22
0
Time sync not working with Windows 10
....
> > >
> > > For Windows 7 workstations, several years ago, I followed the advice in
> > > https://www.meinbergglobal.com/english/info/ntp-w32time.htm which was to do the following on
> > > the Windows 7 workstations:
> > >
> > >
> > > w32tm /config /manualpeerlist:mail,0x8 /syncfromflags:MANUAL
> > > w32tm /config /update
> > >
> > > Check the configuration:
> > >
> > > w32tm /query /source
> > >
> > > This worked and time was in-sync on the WIN7 computers for many years....
2017 Jan 31
0
Samba-4.3 AD-DC Win7pro clients not time syncing
On Mon, 30 Jan 2017 12:16:30 -0500 James B. Byrne wrote:
> I set the client's w32tm configuration this way:
>
> w32tm /config /update /manualpeerlist:"time.nrc.ca time.chu.nrc.ca"
> /syncfromflags:ALL
>
> And when I check the status with
>
> w32tm /query /status
>
> then I see this:
>
> Leap Indicator: 0(no warning)
> Stratum: 3 (secon...
2024 Jan 06
0
Joining Windows 10 Domain Member to Samba AD/DC
...clients. Alternative
> configuration options for the clients are described below."
>
> I've only used a GPO to point to a different time server when the DC
> is incapable of providing the time service (older DC running in a
> container).
> Chris
When I initially did 'w32tm /query /source' on the Windows domain member I got
back time.windows.com, not the DC. On my current Samba DC I had to set the NTP
server on the Windows 10 computers when using the Samba DC.
I missed a couple of commands in my previous post. On the Windows as Admin:
net stop w32time
w32tm...
2024 Jan 05
3
Joining Windows 10 Domain Member to Samba AD/DC
...nisation_on_a_Windows_Domain_Member.
I've created the Group Policy for the "Time Sources". This doesn't seem to be
working. This did work fine with my old 4.8.2 DC, so I know it works in
principle.
I have additional notes and have tried (on the Windows member):
net stop w32time
w32tm /unregister
w32tm /register
net start w32time
I've rebooted both the DC and the Windows member. On the Windows member I still
get:
> w32tm /query /source
Local CMOS Clock
whereas I expect the return to be "dc1.hprs.locl"
I have confirmed that the Group Policy exists and is conf...
2017 Jan 30
3
Samba-4.3 AD-DC Win7pro clients not time syncing
...I have been working on several of the domain clients and I cannot seem
to get them to source from the Samba server. I have confirmed that
ntpd is running on the AD-DC and listening on udp:123. I have also
confirmed that udp:123 is not blocked by the firewall at either end.
I set the client's w32tm configuration this way:
w32tm /config /update /manualpeerlist:"time.nrc.ca time.chu.nrc.ca"
/syncfromflags:ALL
And when I check the status with
w32tm /query /status
then I see this:
Leap Indicator: 0(no warning)
Stratum: 3 (secondary reference - synced by (S)NTP)
Precision: -6 (15.62...
2015 Apr 22
5
Time synchronization issue
Hi,
I have set a Samba AD DC on my network. Version is 4.1.17 on a Debian
Wheezy.
I have an issue on my Windows XP SP3 clients : the time on these computers
is not synchronized with my Domain Controler.
Big problem is, if time difference is considerable (more or less 5
minutes), users can not log in.
On the other hand, my server is correctly synchronized with NTP server.
I don't
2015 Apr 22
1
Time synchronization issue
...er.
>>
>> > I don't understand the reason of my problem, and don't
>know were to start
>> > investigating.
>>
>> > Has anybody got this issue ?
>>
>> Got exactly your problem two days ago.
>> From elevated shell:
>>
>> w32tm /unregister
>> reboot
>> w32tm /register
>> w32tm /config /manualpeerlist:time.example.com /syncfromflags:MANUAL
>> /update
>> time /T (To test if synchronization done correctly)
>>
>> time.example.com is your domain time server - either AD DC or an NTP
>...