2006 Mar 14
1
newhidups driver process crashed shortly after upsd loads
...and query it with upsc. However, it dies shortly after running with a segmentation fault. Here is a sample of the last bit of output from "/usr/local/ups/bin/newhidups -u nut -DDD /dev/hiddev0" (nothing about the process death is in syslog): ================= Object: UPS.PresentStatus.VoltageNotRegulated = 0 entering path_to_string() Looking up 00840002 Looking up ff860080 Object: UPS.PresentStatus.ff860080 = 0 entering path_to_string() Looking up 00840002 Object: UPS.PresentStatus. = 0 entering path_to_string() Looking up 00840002 Object: UPS.PresentStatus. = 0 entering path_to_string() Lookin...
2006 Sep 08
3
newhidups with APC Smart-UPS 1500
Hello, I'm using the stable amd64 port of Debian Linux. I installed (the latest) nut-2.0.1-4 and nut-usb packages for utilizing an APC Smart-UPS 1500 USB. I tried "apcupsd" first but "nut" makes an even more sophisticated impression on me and has more security options. I had problems with the newhidups driver. It didn't find a device with matching VendorID. And
2006 Oct 18
2
newhidups with APC Smart-UPS 1500
....NeedReplacement, Type: Feature, > > Value: 0.000000 > > Path: UPS.PowerSummary.PresentStatus.Overload, Type: Input, Value: > > 0.000000 > > Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, Value: > > 0.000000 > > Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: > > Input, > > Value: 0.000000 > > Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: > > Feature, > > Value: 0.000000 > > Path: UPS.PowerSummary.PresentStatus.ff860080, Type: Input, Value: > > 0.000000 > > Path: UPS.PowerSumm...
2006 Feb 08
2
2.0.3-pre2: Spurious UPS UPS@localhost battery is
Peter Selinger wrote: > Hm. I need more information, as NUT seems to garble the values even > before I can see them. I am not so worried about the date and > temperatures (although, strangely, the battery replacement date > appears to be Sept 25, 2001, which makes no sense). But the voltage is > definitely important. > > [...] > Thanks Peter - I'll send the new
2009 Sep 02
6
Selftest intervall, APC Smart-UPS 750 RM
Hello I recently switched from apcupsd to NUT2.2.2 without any troubles. I tried to figure out how I can configure the self-test intervall. The command upsrw lists only the variables battery.charge.low battery.runtime.low ups.delay.shutdown ups.delay.start The command usbhid-ups -D and the listing under http://obsvermes.org/cgi-bin/nut/upsstats.cgi?host=apcsmart at localhost&treemode
2016 May 28
2
Powercom INF-800 support
...Path: UPS.PowerSummary.PresentStatus.NeedReplacement, Type: Input, ReportID: 0x0a, Offset: 6, Size: 1, Value: 0 0.130638 Path: UPS.PowerSummary.PresentStatus.NeedReplacement, Type: Feature, ReportID: 0x0a, Offset: 6, Size: 1, Value: 0 0.130643 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input, ReportID: 0x0a, Offset: 7, Size: 1, Value: 0 0.130647 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature, ReportID: 0x0a, Offset: 7, Size: 1, Value: 0 0.130652 Path: UPS.PowerSummary.PresentStatus.ShutdownRequested, Type: Input, ReportID: 0x0...
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...0.062147 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Input, ReportID: 0x16, Offset: 9, Size: 1, Value: 0 > 0.062550 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, ReportID: 0x16, Offset: 9, Size: 1, Value: 0 > 0.063188 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input, ReportID: 0x16, Offset: 10, Size: 1, Value: 0 > 0.063408 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature, ReportID: 0x16, Offset: 10, Size: 1, Value: 0 > 0.064299 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Feature, ReportID: 0x17, Offs...
2012 Apr 09
2
libusb_get_report: Unknown error
...Offset: 10, Size: 1, Value: 0 0.944772 Report[buf]: (3 bytes) => 07 8c 00 0.944779 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, ReportID: 0x07, Offset: 10, Size: 1, Value: 0 0.944784 Report[buf]: (3 bytes) => 07 8c 00 0.944791 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input, ReportID: 0x07, Offset: 11, Size: 1, Value: 0 0.944796 Report[buf]: (3 bytes) => 07 8c 00 0.944803 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature, ReportID: 0x07, Offset: 11, Size: 1, Value: 0 0.944808 Report[buf]: (3 bytes) => 07 8c 00 0...
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...2147 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Input, ReportID: 0x16, Offset: 9, Size: 1, Value: 0 >> 0.062550 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, ReportID: 0x16, Offset: 9, Size: 1, Value: 0 >> 0.063188 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input, ReportID: 0x16, Offset: 10, Size: 1, Value: 0 >> 0.063408 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature, ReportID: 0x16, Offset: 10, Size: 1, Value: 0 >> 0.064299 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Feature, ReportID: 0x17...
2015 Jan 09
0
persistent "low battery" condition
On Jan 8, 2015, at 11:43 PM, Graham Menhennitt <graham at menhennitt.com.au> wrote: > Hello Nutters, > > I'm running nut 2.7.2 on FreeBSD 10-stable (via the FreeBSD port) with an APC Back-UPS CS 350 connected via USB. I get persistent (every few minutes) messages logged "battery is low" but I don't understand why. I don't think it's for the reason
2015 Jan 12
2
persistent "low battery" condition
...5.643819 Path: UPS.PowerSummary.PresentStatus.NeedReplacement, Type: Input, ReportID: 0x07, Offset: 9, Size: 1, Value: 0 775.643876 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Input, ReportID: 0x07, Offset: 10, Size: 1, Value: 0 775.643970 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input, ReportID: 0x07, Offset: 11, Size: 1, Value: 0 775.644027 Path: UPS.PowerSummary.PresentStatus.ff860080, Type: Input, ReportID: 0x07, Offset: 12, Size: 1, Value: 0 775.644114 Quick update... 775.653814 Path: UPS.PowerSummary.DelayBeforeShutdown, Type: Feature, Report...
2009 Mar 13
7
Weird Load and Battery Temp Readings
I've acquired and installed NUT 2.4.1 on a D-Link DNS323 NAS. With exception of Load and Battery Temp readings all works well. A upsc ups at localhost command returns; battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 50 battery.date: 2001/09/25 battery.mfr.date: 2008/06/05 battery.runtime: 2122 battery.runtime.low: 120 battery.temperature: 3022999999999998800 battery.type:
2015 Jan 09
2
persistent "low battery" condition
Hello Nutters, I'm running nut 2.7.2 on FreeBSD 10-stable (via the FreeBSD port) with an APC Back-UPS CS 350 connected via USB. I get persistent (every few minutes) messages logged "battery is low" but I don't understand why. I don't think it's for the reason described in the FAQ (but I'm not 100% sure). In the trace output I can see that
2011 Feb 04
1
nut unable to communicate with new APC SMX100 over USB
...Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, ReportID: 0x07, Offset: 10, Size: 1 0.103219 libusb_get_report: error sending control message: Protocol error 0.103324 Can't retrieve Report 07: Protocol error 0.103442 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input, ReportID: 0x07, Offset: 11, Size: 1 0.104218 libusb_get_report: error sending control message: Protocol error 0.104323 Can't retrieve Report 07: Protocol error 0.104437 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature, ReportI...
2016 Sep 11
4
How to get started (Windows)
> On Thu, 8 Sep 2016, Jeff Bowman wrote: > > > (Note: running > > 'upsc ups at localhost' echoes only a blank line to the screen, as do > > both 'upsmon' and 'upsd.') > > Something is wrong here. Is the daemon upsd running? On a Unix/Linux > system, the command ps aux | grep ups gives the report > > upsd 3196 0.0 0.0 13228
2020 Sep 03
2
UPS reboots with APC UPS
...Value: 0 0.635535 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Input, ReportID: 0x16, Offset: 9, Size: 1, Value: 0 0.635543 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, ReportID: 0x16, Offset: 9, Size: 1, Value: 0 0.635552 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input, ReportID: 0x16, Offset: 10, Size: 1, Value: 0 0.635561 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature, ReportID: 0x16, Offset: 10, Size: 1, Value: 0 0.638381 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Feature, ReportID: 0x17, Offset: 0, Si...
2016 Sep 13
2
How to get started (Windows)
...1, Value: 0 0.076421 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Input, ReportID: 0x07, Offset: 10, Size: 1, Value: 0 0.076421 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, ReportID: 0x07, Offset: 10, Size: 1, Value: 0 0.076421 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input, ReportID: 0x07, Offset: 11, Size: 1, Value: 0 0.076421 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature, ReportID: 0x07, Offset: 11, Size: 1, Value: 0 0.076421 Path: UPS.PowerSummary.PresentStatus.ff860080, Type: Input, ReportID: 0x07, Offset: 12, Size...