2006 Mar 14
1
newhidups driver process crashed shortly after upsd loads
...and query it with upsc. However, it dies shortly after running with a
segmentation fault. Here is a sample of the last bit of output from
"/usr/local/ups/bin/newhidups -u nut -DDD /dev/hiddev0" (nothing about the
process death is in syslog):
=================
Object: UPS.PresentStatus.VoltageNotRegulated = 0
entering path_to_string()
Looking up 00840002
Looking up ff860080
Object: UPS.PresentStatus.ff860080 = 0
entering path_to_string()
Looking up 00840002
Object: UPS.PresentStatus. = 0
entering path_to_string()
Looking up 00840002
Object: UPS.PresentStatus. = 0
entering path_to_string()
Lookin...
2006 Sep 08
3
newhidups with APC Smart-UPS 1500
Hello,
I'm using the stable amd64 port of Debian Linux. I installed (the
latest) nut-2.0.1-4 and nut-usb packages for utilizing an APC Smart-UPS
1500 USB. I tried "apcupsd" first but "nut" makes an even more
sophisticated impression on me and has more security options.
I had problems with the newhidups driver. It didn't find a device with
matching VendorID. And
2006 Oct 18
2
newhidups with APC Smart-UPS 1500
....NeedReplacement, Type: Feature,
> > Value: 0.000000
> > Path: UPS.PowerSummary.PresentStatus.Overload, Type: Input, Value:
> > 0.000000
> > Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, Value:
> > 0.000000
> > Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type:
> > Input,
> > Value: 0.000000
> > Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type:
> > Feature,
> > Value: 0.000000
> > Path: UPS.PowerSummary.PresentStatus.ff860080, Type: Input, Value:
> > 0.000000
> > Path: UPS.PowerSumm...
2006 Feb 08
2
2.0.3-pre2: Spurious UPS UPS@localhost battery is
Peter Selinger wrote:
> Hm. I need more information, as NUT seems to garble the values even
> before I can see them. I am not so worried about the date and
> temperatures (although, strangely, the battery replacement date
> appears to be Sept 25, 2001, which makes no sense). But the voltage is
> definitely important.
>
> [...]
>
Thanks Peter - I'll send the new
2009 Sep 02
6
Selftest intervall, APC Smart-UPS 750 RM
Hello
I recently switched from apcupsd to NUT2.2.2 without
any troubles.
I tried to figure out how I can configure the self-test
intervall. The command upsrw lists only the variables
battery.charge.low
battery.runtime.low
ups.delay.shutdown
ups.delay.start
The command usbhid-ups -D and the listing under
http://obsvermes.org/cgi-bin/nut/upsstats.cgi?host=apcsmart at localhost&treemode
2016 May 28
2
Powercom INF-800 support
...Path: UPS.PowerSummary.PresentStatus.NeedReplacement,
Type: Input, ReportID: 0x0a, Offset: 6, Size: 1, Value: 0
0.130638 Path: UPS.PowerSummary.PresentStatus.NeedReplacement,
Type: Feature, ReportID: 0x0a, Offset: 6, Size: 1, Value: 0
0.130643 Path:
UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input,
ReportID: 0x0a, Offset: 7, Size: 1, Value: 0
0.130647 Path:
UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature,
ReportID: 0x0a, Offset: 7, Size: 1, Value: 0
0.130652 Path: UPS.PowerSummary.PresentStatus.ShutdownRequested,
Type: Input, ReportID: 0x0...
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...0.062147 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Input, ReportID: 0x16, Offset: 9, Size: 1, Value: 0
> 0.062550 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, ReportID: 0x16, Offset: 9, Size: 1, Value: 0
> 0.063188 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input, ReportID: 0x16, Offset: 10, Size: 1, Value: 0
> 0.063408 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature, ReportID: 0x16, Offset: 10, Size: 1, Value: 0
> 0.064299 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Feature, ReportID: 0x17, Offs...
2012 Apr 09
2
libusb_get_report: Unknown error
...Offset: 10, Size: 1, Value: 0
0.944772 Report[buf]: (3 bytes) => 07 8c 00
0.944779 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, ReportID: 0x07, Offset: 10, Size: 1, Value: 0
0.944784 Report[buf]: (3 bytes) => 07 8c 00
0.944791 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input, ReportID: 0x07, Offset: 11, Size: 1, Value: 0
0.944796 Report[buf]: (3 bytes) => 07 8c 00
0.944803 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature, ReportID: 0x07, Offset: 11, Size: 1, Value: 0
0.944808 Report[buf]: (3 bytes) => 07 8c 00
0...
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...2147 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Input, ReportID: 0x16, Offset: 9, Size: 1, Value: 0
>> 0.062550 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, ReportID: 0x16, Offset: 9, Size: 1, Value: 0
>> 0.063188 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input, ReportID: 0x16, Offset: 10, Size: 1, Value: 0
>> 0.063408 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature, ReportID: 0x16, Offset: 10, Size: 1, Value: 0
>> 0.064299 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Feature, ReportID: 0x17...
2015 Jan 09
0
persistent "low battery" condition
On Jan 8, 2015, at 11:43 PM, Graham Menhennitt <graham at menhennitt.com.au> wrote:
> Hello Nutters,
>
> I'm running nut 2.7.2 on FreeBSD 10-stable (via the FreeBSD port) with an APC Back-UPS CS 350 connected via USB. I get persistent (every few minutes) messages logged "battery is low" but I don't understand why. I don't think it's for the reason
2015 Jan 12
2
persistent "low battery" condition
...5.643819 Path: UPS.PowerSummary.PresentStatus.NeedReplacement,
Type: Input, ReportID: 0x07, Offset: 9, Size: 1, Value: 0
775.643876 Path: UPS.PowerSummary.PresentStatus.Overload, Type:
Input, ReportID: 0x07, Offset: 10, Size: 1, Value: 0
775.643970 Path:
UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input,
ReportID: 0x07, Offset: 11, Size: 1, Value: 0
775.644027 Path: UPS.PowerSummary.PresentStatus.ff860080, Type:
Input, ReportID: 0x07, Offset: 12, Size: 1, Value: 0
775.644114 Quick update...
775.653814 Path: UPS.PowerSummary.DelayBeforeShutdown, Type:
Feature, Report...
2009 Mar 13
7
Weird Load and Battery Temp Readings
I've acquired and installed NUT 2.4.1 on a D-Link DNS323 NAS. With
exception of Load and Battery Temp readings all works well. A upsc
ups at localhost command returns;
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 50
battery.date: 2001/09/25
battery.mfr.date: 2008/06/05
battery.runtime: 2122
battery.runtime.low: 120
battery.temperature: 3022999999999998800
battery.type:
2015 Jan 09
2
persistent "low battery" condition
Hello Nutters,
I'm running nut 2.7.2 on FreeBSD 10-stable (via the FreeBSD port) with
an APC Back-UPS CS 350 connected via USB. I get persistent (every few
minutes) messages logged "battery is low" but I don't understand why. I
don't think it's for the reason described in the FAQ (but I'm not 100%
sure).
In the trace output I can see that
2011 Feb 04
1
nut unable to communicate with new APC SMX100 over USB
...Path: UPS.PowerSummary.PresentStatus.Overload, Type:
Feature, ReportID: 0x07, Offset: 10, Size: 1
0.103219 libusb_get_report: error sending control message:
Protocol error
0.103324 Can't retrieve Report 07: Protocol error
0.103442 Path:
UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input,
ReportID: 0x07, Offset: 11, Size: 1
0.104218 libusb_get_report: error sending control message:
Protocol error
0.104323 Can't retrieve Report 07: Protocol error
0.104437 Path:
UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature,
ReportI...
2016 Sep 11
4
How to get started (Windows)
> On Thu, 8 Sep 2016, Jeff Bowman wrote:
>
> > (Note: running
> > 'upsc ups at localhost' echoes only a blank line to the screen, as do
> > both 'upsmon' and 'upsd.')
>
> Something is wrong here. Is the daemon upsd running? On a Unix/Linux
> system, the command ps aux | grep ups gives the report
>
> upsd 3196 0.0 0.0 13228
2020 Sep 03
2
UPS reboots with APC UPS
...Value: 0
0.635535 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Input,
ReportID: 0x16, Offset: 9, Size: 1, Value: 0
0.635543 Path: UPS.PowerSummary.PresentStatus.Overload, Type:
Feature, ReportID: 0x16, Offset: 9, Size: 1, Value: 0
0.635552 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated,
Type: Input, ReportID: 0x16, Offset: 10, Size: 1, Value: 0
0.635561 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated,
Type: Feature, ReportID: 0x16, Offset: 10, Size: 1, Value: 0
0.638381 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Feature,
ReportID: 0x17, Offset: 0, Si...
2016 Sep 13
2
How to get started (Windows)
...1, Value: 0
0.076421 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Input, ReportID: 0x07, Offset: 10, Size: 1, Value: 0
0.076421 Path: UPS.PowerSummary.PresentStatus.Overload, Type: Feature, ReportID: 0x07, Offset: 10, Size: 1, Value: 0
0.076421 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Input, ReportID: 0x07, Offset: 11, Size: 1, Value: 0
0.076421 Path: UPS.PowerSummary.PresentStatus.VoltageNotRegulated, Type: Feature, ReportID: 0x07, Offset: 11, Size: 1, Value: 0
0.076421 Path: UPS.PowerSummary.PresentStatus.ff860080, Type: Input, ReportID: 0x07, Offset: 12, Size...