2016 Oct 16
3
nutdrv-qx powercool 1500VA USB UPS
Thanks for the log - apparently we always get valid (apart from 0.191312) but empty replies, not only for index 0x03, but also for the other queried index (0x0c). I've re-looked at the logs you posted on GitHub, but I don't see anything exotic going on there. Maybe we're missing some sort of handshaking or the like: can you post the whole captures/logs, right from when you plug the
2016 Nov 03
0
nutdrv-qx powercool 1500VA USB UPS
Hi Charles, I've added 3 more files to github. https://github.com/mattwire/powercool-ups/blob/master/wireshark-UPSmart-startup.pcapng - captures startup of UPSmart software and continues for about 5 minutes. https://github.com/mattwire/powercool-ups/blob/master/wireshark-UPSmart-ups_off-on.pcapng - UPSmart software is running, UPS is OFF. UPS is switched on and connects to software. https://github.com/mattwire/powercool-ups/blob/master/UPSmart_connected.png - is a screenshot of the UPSmart software when connected (shows some values from UPS). Cheers, Matthew On 16 October 2016 a...