2008 Apr 18
2
My APC ups shutdown but doesn't start again
...input.sensitivity: H
input.transfer.high: 253
input.transfer.low: 208
input.transfer.reason: S
input.voltage: 226.0
input.voltage.maximum: 226.0
input.voltage.minimum: 222.0
output.voltage: 224.0
output.voltage.nominal: 230
ups.delay.shutdown: 300
ups.delay.start: 000
ups.firmware: 738.2.I
ups.id: UPS_IDEN
ups.load: 033.1
ups.mfr: APC
ups.mfr.date: 03/31/07
ups.model: Smart-UPS SC1500
ups.serial: 5S0713T66466
ups.status: OL
ups.test.interval: 1209600
ups.test.result: NO
What can be my problem? Battery is concerned? Please Help.
-------------- next part --------------
An HTML attachment was scrubbed...
2013 Jun 14
1
Battery runtime not displaying
...nsfer.reason: simulated power failure or UPS test
input.voltage: 233.2
input.voltage.maximum: 233.2
input.voltage.minimum: 233.2
output.voltage: 229.3
output.voltage.nominal: 230
ups.delay.shutdown: 020
ups.delay.start: 000
ups.display.language: E
ups.firmware: 416.7.I
ups.firmware.old: 5YI
ups.id: UPS_IDEN
ups.load: 063.0
ups.mfr: APC
ups.mfr.date: 11/22/06
ups.model: Smart-UPS RT 2000 XL??
ups.serial:
ups.status: OL
ups.temperature: 034.6
ups.test.interval: 1209600
ups.test.result: NO
and here with apcsmart driver:
battery.charge: 100.0
battery.voltage: 53.73
device.mfr: APC
device.model: Smart-...
2007 Jul 31
1
Proposed apcsmart driver patch
...0.00
input.quality: FF
input.sensitivity: H
input.transfer.high: 132
input.transfer.low: 103
input.transfer.reason: R
input.voltage: 119.6
input.voltage.maximum: 119.6
input.voltage.minimum: 119.6
output.voltage: 119.6
output.voltage.nominal: 115
ups.delay.shutdown: 020
ups.delay.start: 000
ups.id: UPS_IDEN
ups.load: 019.2
ups.mfr: APC
ups.mfr.date: 07/12/94
ups.model: Smart-UPS
ups.serial: 09000717
ups.status: OL
ups.temperature: 051.3
ups.test.interval: 0
ups.test.result: NO
[Patches follow]
--- drivers/apcsmart.c~ 2006-11-07 18:08:45.000000000 -0800
+++ drivers/apcsmart.c 2007-07-27 12:52:10.000...
2007 Dec 10
1
Driver: apcsmart, SMART-UPS 2200, battery.runtime status information?
...input.sensitivity: H
input.transfer.high: 253
input.transfer.low: 196
input.transfer.reason: T
input.voltage: 000.0
input.voltage.maximum: 000.0
input.voltage.minimum: 000.0
output.voltage: 228.1
output.voltage.nominal: 230
ups.delay.shutdown: 020
ups.delay.start: 000
ups.firmware: 80.14.I
ups.id: UPS_IDEN
ups.load: 000.0
ups.mfr: APC
ups.mfr.date: 01/10/04
ups.model: SMART-UPS 2200
ups.serial: YS0402211565
ups.status: OB
ups.temperature: 024.7
ups.test.interval: 1209600
ups.test.result: NO
What does the battery.runtime represent? It was my understanding that
this was in minutes, but this cannot be...
2013 Jun 07
1
cannot update battery.date value of APC ups battery
...high: 253
input.transfer.low: 196
input.transfer.reason: simulated power failure or UPS test
input.voltage: 224.9
input.voltage.maximum: 226.2
input.voltage.minimum: 224.9
output.voltage: 224.9
output.voltage.nominal: 230
ups.delay.shutdown: 180
ups.delay.start: 000
ups.firmware: 112.1DL4.I
ups.id: UPS_IDEN
ups.load: 047.3
ups.mfr: APC
ups.mfr.date: 01/10/06
ups.model: SMART-UPS 5000 RM DL4
ups.serial: CS0603110577
ups.status: OL
ups.temperature: 024.7
ups.test.interval: 1209600
ups.test.result: NO
Should I be doing something else in order to update battery.date?
Maybe reset the UPS?
Thanks,
Vieri
2019 Sep 24
0
APC Easy UPS
...fer.low: 96
input.transfer.reason: simulated power failure or UPS test
input.voltage: 112.5
input.voltage.maximum: 112.8
input.voltage.minimum: 112.4
output.current: 00.00
output.voltage: 119.4
output.voltage.nominal: 120
ups.delay.shutdown: 180
ups.delay.start: 000
ups.firmware: 441.08CT.I
ups.id: UPS_IDEN
ups.load: 000.0
ups.mfr: APC
ups.mfr.date: 10/12/18
ups.model: SRV 3K A
ups.serial: 9S1838A65050
ups.status: OL
ups.temperature: 030.6
ups.test.interval: 1209600
ups.test.result: NO
2007 Dec 12
1
[PATCH]Support full capabilities on older Smart-UPS 600
...0.00
input.quality: FF
input.sensitivity: L
input.transfer.high: 260
input.transfer.low: 196
input.transfer.reason: R
input.voltage: 239.3
input.voltage.maximum: 243.0
input.voltage.minimum: 240.5
output.voltage: 240.5
output.voltage.nominal: 225
ups.delay.shutdown: 020
ups.delay.start: 000
ups.id: UPS_IDEN
ups.load: 029.6
ups.mfr: APC
ups.mfr.date: 02/22/93
ups.model: Smart-UPS
ups.serial: 30021991
ups.status: OL
ups.temperature: 023.8
ups.test.interval: 0
ups.test.result: NO
thanks,
Dave
Index: drivers/apcsmart.c
===================================================================
--- drivers/apcs...
2013 Mar 07
1
unacceptable utility voltage rate of change
...t.transfer.reason : unacceptable utility voltage rate of change
input.voltage : 226.2
input.voltage.maximum : 226.2
input.voltage.minimum : 226.2
output.voltage : 226.2
output.voltage.nominal : 230
ups.delay.shutdown : 020
ups.delay.start : 000
ups.firmware : 112.1DL4.I
ups.id : UPS_IDEN
ups.load : 039.0
ups.mfr : APC
ups.mfr.date : 09/02/08
ups.model : SMART-UPS 5000 RM DL4
ups.serial : AS0836160289
ups.status : OL
ups.temperature : 022.5
ups.test.interval : 1209600
ups.test.result : NO
Thanks,
Vieri
2005 Jul 09
1
apcsmart varibles
...several years, I have used the apcupsd product, but because of the
nagios support for nut, I am working on switching over.
Under apcupsd, I get tons of information from my UPS:
# /usr/local/sbin/apcaccess status
DATE : Sat Jul 09 12:56:41 CDT 2005
HOSTNAME : homer
RELEASE : 3.8.6
UPSNAME : UPS_IDEN
CABLE : Custom Cable Smart
MODEL : APC Smart-UPS 900
UPSMODE : Net Master
STARTTIME: Sat Jul 09 12:55:48 CDT 2005
SHARE : NetworkUPS
STATUS : ONLINE
LINEV : 112.8 Volts
LOADPCT : 97.7 Percent Load Capacity
BCHARGE : 100.0 Percent
TIMELEFT : 8.0 Minutes
MBATTCHG : 5 Percent
MINTI...
2009 Feb 28
2
APC SMART-UPS 1500 always reporting LB
...input.sensitivity: H
input.transfer.high: 132
input.transfer.low: 103
input.transfer.reason: T
input.voltage: 000.0
input.voltage.maximum: 000.0
input.voltage.minimum: 000.0
output.voltage: 119.0
output.voltage.nominal: 115
ups.delay.shutdown: 020
ups.delay.start: 000
ups.firmware: 70.11.D
ups.id: UPS_IDEN
ups.load: 028.6
ups.mfr: APC
ups.mfr.date: 09/20/00
ups.model: SMART-UPS 1400
ups.serial: XXXXXXXXXXXXX
ups.status: OB LB
ups.temperature: 013.9
ups.test.interval: 1209600
ups.test.result: NO
--[snip]--
Could the APC SPMART-UPS 1500 be defective? What other tests can I perform on it? What other in...
2013 Jun 14
0
Battery runtime not displaying
On Jun 13, 2013, at 7:14 AM, ML mail wrote:
> I just upgraded to Network UPS Tools upsstats 2.6.4 on Debian wheezy and noticed that it does not show the battery runtime anymore, the field is simply empty. It used to work before with NUT 2.4.1. Does anyone know what could be wrong?
>
> I am using the apcsmart UPS driver.
The apcsmart driver was overhauled, and in 2.6.x, the previous
2013 Jun 13
2
Battery runtime not displaying
Hello,
I just upgraded to Network UPS Tools upsstats 2.6.4 on Debian wheezy and noticed that it does not show the battery runtime anymore, the field is simply empty. It used to work before with NUT 2.4.1. Does anyone know what could be wrong?
I am using the apcsmart UPS driver.
Thanks,
M.L.
2006 Nov 23
2
apcsmart and ambient data (was: NUT and MonAMI plugin)
...tage.target.battery "230"
> VAR APC-8000RMXLI ups.delay.shutdown "020"
> VAR APC-8000RMXLI ups.delay.start "000"
> VAR APC-8000RMXLI ups.display.language "E"
> VAR APC-8000RMXLI ups.firmware "477.15.W"
> VAR APC-8000RMXLI ups.id "UPS_IDEN"
> VAR APC-8000RMXLI ups.load "042.0"
> VAR APC-8000RMXLI ups.mfr "APC"
> VAR APC-8000RMXLI ups.mfr.date "07/01/06"
> VAR APC-8000RMXLI ups.model "Smart-UPS RT 8000 XL "
> VAR APC-8000RMXLI ups.serial "NS0627025684 "
> VAR...
2013 Feb 28
8
false low battery alarm
...196
input.transfer.reason : simulated power failure or UPS test
input.voltage : 224.9
input.voltage.maximum : 224.9
input.voltage.minimum : 223.6
output.voltage : 224.9
output.voltage.nominal : 230
ups.delay.shutdown : 020
ups.delay.start : 000
ups.firmware : 112.1DL4.I
ups.id : UPS_IDEN
ups.load : 069.6
ups.mfr : APC
ups.mfr.date : 01/10/06
ups.model : SMART-UPS 5000 RM DL4
ups.serial : CS0603110575
ups.status : OL
ups.temperature : 027.4
ups.test.interval : 1209600
ups.test.result : NO
The NUT version installed is 2.6.3 and I'm using a serial-to-USB hub (1...
2006 Jun 01
0
"Battery constant" value for APC UPS
...sensitivity: H
input.transfer.high: 253
input.transfer.low: 196
input.transfer.reason: T
input.voltage: 243.1
input.voltage.maximum: 244.4
input.voltage.minimum: 241.8
output.voltage: 243.1
output.voltage.target.battery: 230
ups.delay.shutdown: 180
ups.delay.start: 000
ups.firmware: 92.11.I
ups.id: UPS_IDEN
ups.load: 045.2
ups.mfr: APC
ups.mfr.date: 02/15/01
ups.model: SMART-UPS 3000 RM
ups.serial: [deleted]
ups.status: OL LB
ups.temperature: 057.6
ups.test.interval: 1209600
ups.test.result: NO
Having run some tests by powering off the mains and looking at the rate
of battery discharge, I would guess...
2020 Jun 21
2
Server did not shut down
2008 Nov 10
1
Can't make Smart-UPS 1500 shutdown over serial
...input.sensitivity: H
input.transfer.high: 253
input.transfer.low: 208
input.transfer.reason: S
input.voltage: 236.1
input.voltage.maximum: 236.1
input.voltage.minimum: 233.2
output.voltage: 236.1
output.voltage.nominal: 230
ups.delay.shutdown: 090
ups.delay.start: 000
ups.firmware: 601.3.I
ups.id: UPS_IDEN
ups.load: 004.5
ups.mfr: APC
ups.mfr.date: 09/06/05
ups.model: Smart-UPS 1500
ups.serial: AS0537230534(
ups.status: OL
ups.temperature: 031.0
ups.test.interval: 1209600
ups.test.result: NO
Are there some log files I should be looking at, or can I put the driver
in a debug mode somehow? I want to g...
2009 Mar 28
1
APCUPSD port 3551 permission problem
...#
# ========== Configuration statements used in updating the UPS EPROM =========
#
#
# These statements are used only by apctest when choosing "Set EEPROM with conf
# file values" from the EEPROM menu. THESE STATEMENTS HAVE NO EFFECT ON APCUPSD.
#
# UPS name, max 8 characters
#UPSNAME UPS_IDEN
# Battery date - 8 characters
#BATTDATE mm/dd/yy
# Sensitivity to line voltage quality (H cause faster transfer to batteries)
# SENSITIVITY H M L (default = H)
#SENSITIVITY H
# UPS delay after power return (seconds)
# WAKEUP 000 060 180 300 (default = 0)
#WAKEUP 60
# UPS Grace period...
2006 Apr 26
1
RE nut 2.0 fentonups and Xanto S3000R
Hi Henning,
you should get in touch with Carlos, who his developing a generic
megatec driver (available from svn:
http://eu1.networkupstools.org/source.html)
Arnaud
--
Linux / Unix Expert - MGE UPS SYSTEMS - R&D Dpt
Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/
Debian Developer - http://people.debian.org/~aquette/
OpenSource Developer -