2008 Apr 18
2
My APC ups shutdown but doesn't start again
...input.sensitivity: H input.transfer.high: 253 input.transfer.low: 208 input.transfer.reason: S input.voltage: 226.0 input.voltage.maximum: 226.0 input.voltage.minimum: 222.0 output.voltage: 224.0 output.voltage.nominal: 230 ups.delay.shutdown: 300 ups.delay.start: 000 ups.firmware: 738.2.I ups.id: UPS_IDEN ups.load: 033.1 ups.mfr: APC ups.mfr.date: 03/31/07 ups.model: Smart-UPS SC1500 ups.serial: 5S0713T66466 ups.status: OL ups.test.interval: 1209600 ups.test.result: NO What can be my problem? Battery is concerned? Please Help. -------------- next part -------------- An HTML attachment was scrubbed...
2013 Jun 14
1
Battery runtime not displaying
...nsfer.reason: simulated power failure or UPS test input.voltage: 233.2 input.voltage.maximum: 233.2 input.voltage.minimum: 233.2 output.voltage: 229.3 output.voltage.nominal: 230 ups.delay.shutdown: 020 ups.delay.start: 000 ups.display.language: E ups.firmware: 416.7.I ups.firmware.old: 5YI ups.id: UPS_IDEN ups.load: 063.0 ups.mfr: APC ups.mfr.date: 11/22/06 ups.model: Smart-UPS RT 2000 XL?? ups.serial: ups.status: OL ups.temperature: 034.6 ups.test.interval: 1209600 ups.test.result: NO and here with apcsmart driver: battery.charge: 100.0 battery.voltage: 53.73 device.mfr: APC device.model: Smart-...
2007 Jul 31
1
Proposed apcsmart driver patch
...0.00 input.quality: FF input.sensitivity: H input.transfer.high: 132 input.transfer.low: 103 input.transfer.reason: R input.voltage: 119.6 input.voltage.maximum: 119.6 input.voltage.minimum: 119.6 output.voltage: 119.6 output.voltage.nominal: 115 ups.delay.shutdown: 020 ups.delay.start: 000 ups.id: UPS_IDEN ups.load: 019.2 ups.mfr: APC ups.mfr.date: 07/12/94 ups.model: Smart-UPS ups.serial: 09000717 ups.status: OL ups.temperature: 051.3 ups.test.interval: 0 ups.test.result: NO [Patches follow] --- drivers/apcsmart.c~ 2006-11-07 18:08:45.000000000 -0800 +++ drivers/apcsmart.c 2007-07-27 12:52:10.000...
2007 Dec 10
1
Driver: apcsmart, SMART-UPS 2200, battery.runtime status information?
...input.sensitivity: H input.transfer.high: 253 input.transfer.low: 196 input.transfer.reason: T input.voltage: 000.0 input.voltage.maximum: 000.0 input.voltage.minimum: 000.0 output.voltage: 228.1 output.voltage.nominal: 230 ups.delay.shutdown: 020 ups.delay.start: 000 ups.firmware: 80.14.I ups.id: UPS_IDEN ups.load: 000.0 ups.mfr: APC ups.mfr.date: 01/10/04 ups.model: SMART-UPS 2200 ups.serial: YS0402211565 ups.status: OB ups.temperature: 024.7 ups.test.interval: 1209600 ups.test.result: NO What does the battery.runtime represent? It was my understanding that this was in minutes, but this cannot be...
2013 Jun 07
1
cannot update battery.date value of APC ups battery
...high: 253 input.transfer.low: 196 input.transfer.reason: simulated power failure or UPS test input.voltage: 224.9 input.voltage.maximum: 226.2 input.voltage.minimum: 224.9 output.voltage: 224.9 output.voltage.nominal: 230 ups.delay.shutdown: 180 ups.delay.start: 000 ups.firmware: 112.1DL4.I ups.id: UPS_IDEN ups.load: 047.3 ups.mfr: APC ups.mfr.date: 01/10/06 ups.model: SMART-UPS 5000 RM DL4 ups.serial: CS0603110577 ups.status: OL ups.temperature: 024.7 ups.test.interval: 1209600 ups.test.result: NO Should I be doing something else in order to update battery.date? Maybe reset the UPS? Thanks, Vieri
2019 Sep 24
0
APC Easy UPS
...fer.low: 96 input.transfer.reason: simulated power failure or UPS test input.voltage: 112.5 input.voltage.maximum: 112.8 input.voltage.minimum: 112.4 output.current: 00.00 output.voltage: 119.4 output.voltage.nominal: 120 ups.delay.shutdown: 180 ups.delay.start: 000 ups.firmware: 441.08CT.I ups.id: UPS_IDEN ups.load: 000.0 ups.mfr: APC ups.mfr.date: 10/12/18 ups.model: SRV 3K A ups.serial: 9S1838A65050 ups.status: OL ups.temperature: 030.6 ups.test.interval: 1209600 ups.test.result: NO
2007 Dec 12
1
[PATCH]Support full capabilities on older Smart-UPS 600
...0.00 input.quality: FF input.sensitivity: L input.transfer.high: 260 input.transfer.low: 196 input.transfer.reason: R input.voltage: 239.3 input.voltage.maximum: 243.0 input.voltage.minimum: 240.5 output.voltage: 240.5 output.voltage.nominal: 225 ups.delay.shutdown: 020 ups.delay.start: 000 ups.id: UPS_IDEN ups.load: 029.6 ups.mfr: APC ups.mfr.date: 02/22/93 ups.model: Smart-UPS ups.serial: 30021991 ups.status: OL ups.temperature: 023.8 ups.test.interval: 0 ups.test.result: NO thanks, Dave Index: drivers/apcsmart.c =================================================================== --- drivers/apcs...
2013 Mar 07
1
unacceptable utility voltage rate of change
...t.transfer.reason : unacceptable utility voltage rate of change input.voltage : 226.2 input.voltage.maximum : 226.2 input.voltage.minimum : 226.2 output.voltage : 226.2 output.voltage.nominal : 230 ups.delay.shutdown : 020 ups.delay.start : 000 ups.firmware : 112.1DL4.I ups.id : UPS_IDEN ups.load : 039.0 ups.mfr : APC ups.mfr.date : 09/02/08 ups.model : SMART-UPS 5000 RM DL4 ups.serial : AS0836160289 ups.status : OL ups.temperature : 022.5 ups.test.interval : 1209600 ups.test.result : NO Thanks, Vieri
2005 Jul 09
1
apcsmart varibles
...several years, I have used the apcupsd product, but because of the nagios support for nut, I am working on switching over. Under apcupsd, I get tons of information from my UPS: # /usr/local/sbin/apcaccess status DATE : Sat Jul 09 12:56:41 CDT 2005 HOSTNAME : homer RELEASE : 3.8.6 UPSNAME : UPS_IDEN CABLE : Custom Cable Smart MODEL : APC Smart-UPS 900 UPSMODE : Net Master STARTTIME: Sat Jul 09 12:55:48 CDT 2005 SHARE : NetworkUPS STATUS : ONLINE LINEV : 112.8 Volts LOADPCT : 97.7 Percent Load Capacity BCHARGE : 100.0 Percent TIMELEFT : 8.0 Minutes MBATTCHG : 5 Percent MINTI...
2009 Feb 28
2
APC SMART-UPS 1500 always reporting LB
...input.sensitivity: H input.transfer.high: 132 input.transfer.low: 103 input.transfer.reason: T input.voltage: 000.0 input.voltage.maximum: 000.0 input.voltage.minimum: 000.0 output.voltage: 119.0 output.voltage.nominal: 115 ups.delay.shutdown: 020 ups.delay.start: 000 ups.firmware: 70.11.D ups.id: UPS_IDEN ups.load: 028.6 ups.mfr: APC ups.mfr.date: 09/20/00 ups.model: SMART-UPS 1400 ups.serial: XXXXXXXXXXXXX ups.status: OB LB ups.temperature: 013.9 ups.test.interval: 1209600 ups.test.result: NO --[snip]-- Could the APC SPMART-UPS 1500 be defective? What other tests can I perform on it? What other in...
2013 Jun 14
0
Battery runtime not displaying
On Jun 13, 2013, at 7:14 AM, ML mail wrote: > I just upgraded to Network UPS Tools upsstats 2.6.4 on Debian wheezy and noticed that it does not show the battery runtime anymore, the field is simply empty. It used to work before with NUT 2.4.1. Does anyone know what could be wrong? > > I am using the apcsmart UPS driver. The apcsmart driver was overhauled, and in 2.6.x, the previous
2013 Jun 13
2
Battery runtime not displaying
Hello, I just upgraded to Network UPS Tools upsstats 2.6.4 on Debian wheezy and noticed that it does not show the battery runtime anymore, the field is simply empty. It used to work before with NUT 2.4.1. Does anyone know what could be wrong? I am using the apcsmart UPS driver. Thanks, M.L.
2006 Nov 23
2
apcsmart and ambient data (was: NUT and MonAMI plugin)
...tage.target.battery "230" > VAR APC-8000RMXLI ups.delay.shutdown "020" > VAR APC-8000RMXLI ups.delay.start "000" > VAR APC-8000RMXLI ups.display.language "E" > VAR APC-8000RMXLI ups.firmware "477.15.W" > VAR APC-8000RMXLI ups.id "UPS_IDEN" > VAR APC-8000RMXLI ups.load "042.0" > VAR APC-8000RMXLI ups.mfr "APC" > VAR APC-8000RMXLI ups.mfr.date "07/01/06" > VAR APC-8000RMXLI ups.model "Smart-UPS RT 8000 XL " > VAR APC-8000RMXLI ups.serial "NS0627025684 " > VAR...
2013 Feb 28
8
false low battery alarm
...196 input.transfer.reason : simulated power failure or UPS test input.voltage : 224.9 input.voltage.maximum : 224.9 input.voltage.minimum : 223.6 output.voltage : 224.9 output.voltage.nominal : 230 ups.delay.shutdown : 020 ups.delay.start : 000 ups.firmware : 112.1DL4.I ups.id : UPS_IDEN ups.load : 069.6 ups.mfr : APC ups.mfr.date : 01/10/06 ups.model : SMART-UPS 5000 RM DL4 ups.serial : CS0603110575 ups.status : OL ups.temperature : 027.4 ups.test.interval : 1209600 ups.test.result : NO The NUT version installed is 2.6.3 and I'm using a serial-to-USB hub (1...
2006 Jun 01
0
"Battery constant" value for APC UPS
...sensitivity: H input.transfer.high: 253 input.transfer.low: 196 input.transfer.reason: T input.voltage: 243.1 input.voltage.maximum: 244.4 input.voltage.minimum: 241.8 output.voltage: 243.1 output.voltage.target.battery: 230 ups.delay.shutdown: 180 ups.delay.start: 000 ups.firmware: 92.11.I ups.id: UPS_IDEN ups.load: 045.2 ups.mfr: APC ups.mfr.date: 02/15/01 ups.model: SMART-UPS 3000 RM ups.serial: [deleted] ups.status: OL LB ups.temperature: 057.6 ups.test.interval: 1209600 ups.test.result: NO Having run some tests by powering off the mains and looking at the rate of battery discharge, I would guess...
2020 Jun 21
2
Server did not shut down
2008 Nov 10
1
Can't make Smart-UPS 1500 shutdown over serial
...input.sensitivity: H input.transfer.high: 253 input.transfer.low: 208 input.transfer.reason: S input.voltage: 236.1 input.voltage.maximum: 236.1 input.voltage.minimum: 233.2 output.voltage: 236.1 output.voltage.nominal: 230 ups.delay.shutdown: 090 ups.delay.start: 000 ups.firmware: 601.3.I ups.id: UPS_IDEN ups.load: 004.5 ups.mfr: APC ups.mfr.date: 09/06/05 ups.model: Smart-UPS 1500 ups.serial: AS0537230534( ups.status: OL ups.temperature: 031.0 ups.test.interval: 1209600 ups.test.result: NO Are there some log files I should be looking at, or can I put the driver in a debug mode somehow? I want to g...
2009 Mar 28
1
APCUPSD port 3551 permission problem
...# # ========== Configuration statements used in updating the UPS EPROM ========= # # # These statements are used only by apctest when choosing "Set EEPROM with conf # file values" from the EEPROM menu. THESE STATEMENTS HAVE NO EFFECT ON APCUPSD. # # UPS name, max 8 characters #UPSNAME UPS_IDEN # Battery date - 8 characters #BATTDATE mm/dd/yy # Sensitivity to line voltage quality (H cause faster transfer to batteries) # SENSITIVITY H M L (default = H) #SENSITIVITY H # UPS delay after power return (seconds) # WAKEUP 000 060 180 300 (default = 0) #WAKEUP 60 # UPS Grace period...
2006 Apr 26
1
RE nut 2.0 fentonups and Xanto S3000R
Hi Henning, you should get in touch with Carlos, who his developing a generic megatec driver (available from svn: http://eu1.networkupstools.org/source.html) Arnaud -- Linux / Unix Expert - MGE UPS SYSTEMS - R&D Dpt Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/ Debian Developer - http://people.debian.org/~aquette/ OpenSource Developer -