search for: sc1000

Displaying 5 results from an estimated 5 matches for "sc1000".

Did you mean: tc1000
2015 May 13
0
Problem connecting to APC Smart UPS SC1000 on Windows
Hello. I have problem with connecting to APC SC1000 using NUT port for windows 2.6.5-6. Last working version is NUT 2.6.1-1. With the same config files it works well. c:\NUT\bin>apcsmart.exe -a SC1000 Network UPS Tools - APC Smart protocol driver 3.1 (Windows-v2.6.5-5-7-g72f380c) APC command table version 3.1 w32_serial_open (COM3) setting init...
2007 May 31
0
Proposed addition to apcsmart driver
...rodsky <abrodsky at acs.uwinnipeg.ca>: > Hi, > > My name is Alex Brodsky, I am a faculty member at University of > Winnipeg. > > I have been using NUT for a while now (on OpenBSD), but noticed that > I could not program the EEPROM values (using upsrw) of my Smart UPS > SC1000, even though, it worked fine with a Smart UPS 1500. The > manual for the SC1000 claims that the eeprom values could be programmed. > > I investigated further and discovered that the result of the 'a' > command to the SC1000 UPS, which queries the available commands for > the...
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
Hello. Trouble to communicate with APC SmartUPS via serial port. UPS connected to the com1 port on windows host. Communication witch hyperterm works well. There is a log: YSM ^ASmart-UPS SC1000 n5S0713T63247 m03/29/07 L240.0 B27.10 apcupsd also can communicate with the UPS and works well. running apcsmart -a ups gives the following: com1: device reports different attributes than what were set unable to detect an APC Smart protocol UPS on port com1 check the cabling, port name or model...
2014 Jan 14
0
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
On 2014-01-14 10:12, dstrr wrote: > Hello. > Trouble to communicate with APC SmartUPS via serial port. > UPS connected to the com1 port on windows host. > Communication witch hyperterm works well. > There is a log: > > YSM > ^ASmart-UPS SC1000 > n5S0713T63247 > m03/29/07 > L240.0 > B27.10 > > apcupsd also can communicate with the UPS and works well. > > running apcsmart -a ups gives the following: > > com1: device reports different attributes than what were set > unable to detect an APC Smart protocol UPS...
2000 Mar 06
1
smbd processes won't go away
Running Samba 2.0.6, on Sun SC1000 (4 CPUs) with Solaris 2.6 smbd processes don't seem to terminate although the connections don't show-up with netstat. The client session seems to terminate, and the connection is terminated, but the smbd process seems to hang around waiting. smb.conf specifies "deadtime=5", a...