search for: runtimetoempty

Displaying 20 results from an estimated 80 matches for "runtimetoempty".

2005 Aug 02
0
newhidups for APC Back-UPS ES 650
...APCStatusFlag Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.ConfigVoltage Path: UPS.PowerSummary.Voltage Path: UPS.PowerSummary.iManufacturer Path: UPS.PowerSummary.CapacityMode Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.DesignCapacity Path: UPS.PowerSummary.FullChargeCapacity Path: UPS.PowerSummary.WarningCapacityLimit Path: UPS.PowerSummary.CapacityGranularity2 Path: UPS.PowerSummary.RemainingCapacityLimit Path: UPS.PowerSummary.CapacityGranularity1 Pat...
2015 Mar 13
0
Problems with NUT 2.7.2 on CentOS 7 and using the Mini-Box OpenUPS
...22056 PhyMax = 0, PhyMin = 0, LogMax = 16777215, LogMin = 0 > 0.422069 Unit = 00001001, UnitExp = 0 > 0.422080 Exponent = 0 > 0.422093 hid_lookup_path: 00840004 -> UPS > 0.422107 hid_lookup_path: 00840024 -> PowerSummary > 0.422121 hid_lookup_path: 00850068 -> RunTimeToEmpty > 0.422146 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, ReportID: > 0x60, Offset: 0, Size: 24, Value: 3.9321e+06 That looks like a calibration problem: 3.9 million seconds of runtime is a while. > 0.422163 Report[buf]: (4 bytes) => 60 c4 ff 3b > 0.422177 PhyMax =...
2005 Jul 22
1
Another HID USB UPS
...APCStatusFlag Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.ConfigVoltage Path: UPS.PowerSummary.Voltage Path: UPS.PowerSummary.iManufacturer Path: UPS.PowerSummary.CapacityMode Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.DesignCapacity Path: UPS.PowerSummary.FullChargeCapacity Path: UPS.PowerSummary.WarningCapacityLimit Path: UPS.PowerSummary.CapacityGranularity2 Path: UPS.PowerSummary.RemainingCapacityLimit Path: UPS.PowerSummary.CapacityGranularity1 Pat...
2005 Aug 26
0
NUT patches
...APCStatusFlag Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.ConfigVoltage Path: UPS.PowerSummary.Voltage Path: UPS.PowerSummary.iManufacturer Path: UPS.PowerSummary.CapacityMode Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.DesignCapacity Path: UPS.PowerSummary.FullChargeCapacity Path: UPS.PowerSummary.WarningCapacityLimit Path: UPS.PowerSummary.CapacityGranularity2 Path: UPS.PowerSummary.RemainingCapacityLimit Path: UPS.PowerSummary.CapacityGranularity1 Pat...
2014 Apr 05
0
I can't make changes to ups.delay.shutdown to stick
On Apr 5, 2014, at 7:18 AM, Mick wrote: > $ upsrw -s "ups.delay.shutdown"="30" iDowell at localhost > Username (suzy): admin > Password: > OK This command is sending the value to the UPS (via the usbhid-ups driver). > $ upsc iDowell at localhost ups.delay.shutdown > 30 And this command ends up reading the value back from the UPS. > However, following
2006 Nov 11
1
Help with newhidups subdriver for Dynex UPS
...ainingCapacityLimit, Type: Feature, Value: 10.000000 Path: UPS.PowerSummary.FullChargeCapacity, Type: Feature, Value: 100.000000 Path: UPS.PowerSummary.RemainingCapacity, Type: Input, Value: 120.000000 Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, Value: 120.000000 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, Value: 240.000000 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, Value: 240.000000 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Input, Value: 300.000000 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Feature, Value: 300.000000 Path: UPS.PowerSummary.ConfigVoltage, Type: F...
2014 Apr 05
2
I can't make changes to ups.delay.shutdown to stick
...Offset: 32, Size: 8, Value: 100 0.994821 Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, ReportID: 0x16, Offset: 0, Size: 8, Value: 100 0.994841 Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x16, Offset: 0, Size: 8, Value: 100 0.994857 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, ReportID: 0x16, Offset: 8, Size: 16, Value: 650 0.994872 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x16, Offset: 8, Size: 16, Value: 650 0.998820 Path: UPS.PowerSummary.PresentStatus.CommunicationLost, Type: Input, ReportID: 0x01, Offset: 0, Size: 1, Val...
2005 Aug 29
1
Belkin and newhidups
Hi Peter, I got all your patches and applied them, and I wanted to say kudos for a great job done. This is the output of upsc that I'm getting right now. I had the same issue when using any cvs version (from two weeks ago) that made my UPS go into a state where it wasn't functioning normally (checking the kernel log shows that it cannot be connected and I had around a page of DEVFS_USB
2015 Jan 09
2
persistent "low battery" condition
...an APC Back-UPS CS 350 connected via USB. I get persistent (every few minutes) messages logged "battery is low" but I don't understand why. I don't think it's for the reason described in the FAQ (but I'm not 100% sure). In the trace output I can see that UPS.PowerSummary.RunTimeToEmpty is usually around 150 - 170 seconds. Occasionally it drops to 105. I don't see any reason why the load would be changing significantly. In any case, I've set the threshold to 90 seconds in ups.conf. See below for debug info. If somebody could offer suggestions on how to fix it, I'd be...
2014 Apr 05
2
I can't make changes to ups.delay.shutdown to stick
Hi All, I'm using an iDowell UPS with the usbhid-ups driver: $ upsc iDowell at localhost battery.charge: 100 battery.charge.low: 15 battery.runtime: 650 battery.type: Pb acc device.mfr: iDowell device.model: iBox device.serial: 00000001 device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto
2015 Mar 13
3
Problems with NUT 2.7.2 on CentOS 7 and using the Mini-Box OpenUPS
I?m a new user of NUT and the OpenUPS - in the past I?ve used APC hardware and apcupsd on Centos 6. I?ve built NUT 2.7.2 from source but used the OpenUPS HID driver v0.4 that?s in github. I?m using firmware version 1.5 on the openups which is the latest published version; I?ve also tried 1.7 which Mini-box sent to me but reverted to the published version. Their support seems a bit slow! I?ve got
2005 Oct 04
0
Problems connecting to APC/Smart-UPS 3000 RM
...RemainingCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.CapacityGranularity1 Path: UPS.PowerSummary.CapacityGranularity2 Path: UPS.PowerSummary.WarningCapacityLimit Path: UPS.PowerSummary.RemainingCapacityLimit Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.DelayBeforeShutdown Path: UPS.PowerSummary.DelayBeforeReboot Path: UPS.PowerSummary.RemainingTimeLimit Path: UPS.PowerSummary.RemainingTimeLimit Path: UPS.PowerSummary.ConfigVoltage Path: UPS.PowerSummary.Voltage Path: UPS.PowerSummary.Au...
2010 Feb 18
2
HP R1500 G2 UPS
...pe: Feature, ReportID: 0x28, Offset: 0, Size: 8, Value: 36.000000 Path: UPS.PowerSummary.iSerialNumber, Type: Feature, ReportID: 0x29, Offset: 0, Size: 8, Value: 50.000000 Path: UPS.PowerSummary.iManufacturer, Type: Feature, ReportID: 0x2b, Offset: 0, Size: 8, Value: 4.000000 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x35, Offset: 0, Size: 24, Value: 1476.000000 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, ReportID: 0x35, Offset: 0, Size: 24, Value: 1476.000000 Path: UPS.PowerSummary.Input.ConfigVoltage, Type: Feature, ReportID: 0x30, Offset: 0, Size: 8, Value: 230.000000 Path:...
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...ze: 8, Value: 2 > 0.038282 Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x0c, Offset: 0, Size: 8, Value: 18 > 0.039169 Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, ReportID: 0x0c, Offset: 0, Size: 8, Value: 18 > 0.040008 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x0c, Offset: 8, Size: 16, Value: 262 > 0.040842 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, ReportID: 0x0c, Offset: 8, Size: 16, Value: 262 > 0.042150 Path: UPS.PowerSummary.DesignCapacity, Type: Feature, ReportID: 0x0d, Offset: 0, Size: 8, Value:...
2007 Jan 26
1
newhidups output for Geek Squad GS1285U
...iningCapacityLimit, Type: Feature, Value: 10.000000 Path: UPS.PowerSummary.FullChargeCapacity, Type: Feature, Value: 100.000000 Path: UPS.PowerSummary.RemainingCapacity, Type: Input, Value: 100.000000 Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, Value: 100.000000 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, Value: 5722.000000 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, Value: 5722.000000 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Input, Value: 300.000000 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Feature, Value: 300.000000 Path: UPS.PowerSummary.ConfigVoltage, Type:...
2015 Jun 07
2
libusb_get_string: invalid argument
...Offset: 0, Size: 8, Value: 2 0.795076 Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, ReportID: 0x2a, Offset: 0, Size: 8, Value: 24 0.811944 Path: UPS.PowerSummary.CapacityMode, Type: Feature, ReportID: 0x33, Offset: 0, Size: 8, Value: 2 0.828701 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x35, Offset: 0, Size: 16, Value: 1440 0.828799 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, ReportID: 0x35, Offset: 0, Size: 16, Value: 1440 0.845443 Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x34, Offset: 0, Size: 8, Value: 100...
2015 Jun 09
0
libusb_get_string: invalid argument
...Offset: 0, Size: 8, Value: 2 0.852997 Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, ReportID: 0x2a, Offset: 0, Size: 8, Value: 24 0.869730 Path: UPS.PowerSummary.CapacityMode, Type: Feature, ReportID: 0x33, Offset: 0, Size: 8, Value: 2 0.886509 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x35, Offset: 0, Size: 16, Value: 1440 0.886923 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, ReportID: 0x35, Offset: 0, Size: 16, Value: 1440 0.903240 Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x34, Offset: 0, Size: 8, Value: 100...
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...lue: 2 >> 0.038282 Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x0c, Offset: 0, Size: 8, Value: 18 >> 0.039169 Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, ReportID: 0x0c, Offset: 0, Size: 8, Value: 18 >> 0.040008 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x0c, Offset: 8, Size: 16, Value: 262 >> 0.040842 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, ReportID: 0x0c, Offset: 8, Size: 16, Value: 262 >> 0.042150 Path: UPS.PowerSummary.DesignCapacity, Type: Feature, ReportID: 0x0d, Offset: 0, Size: 8, V...
2013 Aug 07
4
HP R1500 G3 problems
...set: 0, Size: 8, Value: 36 0.409123 Path: UPS.PowerSummary.iSerialNumber, Type: Feature, ReportID: 0x29, Offset: 0, Size: 8, Value: 50 0.413115 Path: UPS.PowerSummary.iManufacturer, Type: Feature, ReportID: 0x2b, Offset: 0, Size: 8, Value: 4 0.417132 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x35, Offset: 0, Size: 24, Value: 23917 0.417251 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, ReportID: 0x35, Offset: 0, Size: 24, Value: 23917 0.421135 Path: UPS.PowerSummary.Input.ConfigVoltage, Type: Feature, ReportID: 0x30, Offset: 0, Size: 8,...
2015 Jan 09
0
persistent "low battery" condition
...I don't think it's for the reason described in the FAQ (but I'm not 100% sure). I think that FAQ #39 ("My APC UPS keeps reporting OL LB, even after it?s been charging for many hours") refers to a continuous LB state. > In the trace output I can see that UPS.PowerSummary.RunTimeToEmpty is usually around 150 - 170 seconds. Occasionally it drops to 105. I don't see any reason why the load would be changing significantly. In any case, I've set the threshold to 90 seconds in ups.conf. > > See below for debug info. > > If somebody could offer suggestions on how t...