search for: rpi4

Displaying 20 results from an estimated 60 matches for "rpi4".

Did you mean: rpi
2020 Jan 07
4
nut on armhf, r-pi4b IOW
...run on an armhf platform? Mmmm, possibly silly Q, its available in the raspbian buster repo's. So I had apt install it. But the installer failed to start it, not surprising because its not been configured yet nor has whatever cable cyberpower needs been connected. The apt install log: pi at rpi4:/media/pi/workspace/rpi4-kernel $ sudo apt install nut Reading package lists... Done Building dependency tree Reading state information... Done The following additional packages will be installed: libupsclient4 nut-client nut-server Suggested packages: nut-monitor nut-cgi nut-ipmi nut-snmp nut-...
2020 Sep 05
1
ups not being started sat reboot
On Sep 5, 2020, at 5:23 AM, Roger Price wrote: > > On Sat, 5 Sep 2020, Gene Heskett wrote: > >> But runs normally if started. On a rpi4 running an uptodate raspbian buster, how do I set it to auto start at boot time? > > Hello Gene, By "auto start" I assume you mean the automatic power on of a box when wall power returns after a power failure. For this to work, two things are needed: > Roger, I don't have a...
2020 Jun 22
2
reboot of nut managment node resets Tripplite SMX1000LCD
Hi, I'm not sure if it is a bug or a feature. I'm running Ubuntu 20.04 on my RPi4 which connects to the UPS over USB. I have noticed whenever I reboot my RPi4. It resets the UPS ( I can hear the relay) -- Powerloss. Any pointers to disable this annoying bug / feature. ups.conf: --8<---- [tripp] driver = usbhid-ups port = auto vendorid = 09ae productid = 200...
2020 Jan 07
0
nut on armhf, r-pi4b IOW
On my raspbian buster RPi3's that run nut, no problems with the stock nut packages provided so I wouldn't expect problems with your RPi4 once you get the cable and configs sorted out. I use the RPi3's as nut-servers to monitor and manage my Tripp-Lite UPS systems, the other local systems run nut-client and communicate with the RPi. --Larry On Tue, Jan 7, 2020 at 6:28 AM Gene Heskett <gheskett at shentel.net> wrote: >...
2020 Jun 22
2
Low Battery Problems
...Monday 22 June 2020 15:26:23 Larry Fahnoe wrote: > On Mon, Jun 22, 2020 at 12:26 PM Gene Heskett <gheskett at shentel.net> wrote: > > So I just edited /etc/nut/upsd.users to add both the commands it > > claims to have but get this response to either: > > > > pi at rpi4:~ $ upscmd myups test.battery.start.quick > > Username (pi): pi > > Password: > > Unexpected response from upsd: ERR ACCESS-DENIED > > pi at rpi4:~ $ upscmd myups test.battery.start.deep > > Username (pi): pi > > Password: > > Unexpected response from upsd:...
2020 Jun 22
5
Low Battery Problems
On Monday 22 June 2020 09:50:50 Larry Fahnoe wrote: > On Mon, Jun 22, 2020 at 8:27 AM Gene Heskett <gheskett at shentel.net> wrote: > > > On Jun 22, 2020, at 8:52 AM, Gene Heskett wrote: > > > > pi at rpi4:~ $ upscmd myups *test.battery.start.quick* > > > > Username (pi): > > > > Password: > > > > Unexpected response from upsd: ERR ACCESS-DENIED > > > > [pi] > > password = xxxxxxxxxxxxx > > instcmds...
2020 Jun 22
2
Low Battery Problems
On Monday 22 June 2020 09:18:29 Charles Lepple wrote: > On Jun 22, 2020, at 8:52 AM, Gene Heskett wrote: > > pi at rpi4:~ $ upscmd myups test.battery.start.quick > > Username (pi): > > Password: > > Unexpected response from upsd: ERR ACCESS-DENIED > > > > Looking at /etc/nut/uspd.users, I (me, pi) should be able to do > > that. ??? > > Hi Gene, > > You have a [pi] sect...
2020 Jan 08
2
nut on armhf, r-pi4b IOW
.../system/nut-monitor.service; enabled; > > vendor preset: enabled) > > Active: failed (Result: protocol) since Tue 2020-01-07 07:19:19 > > EST; 116ms ago > > Process: 32343 ExecStart=/sbin/upsmon (code=exited, > > status=0/SUCCESS) > > > > Jan 07 07:19:19 rpi4 systemd[1]: Starting Network UPS Tools - power > > device monitor and shutdown controller... > > Jan 07 07:19:19 rpi4 upsmon[32343]: upsmon disabled, please adjust > > the configuration to your needs > > Jan 07 07:19:19 rpi4 upsmon[32343]: Then set MODE to a suitable > &g...
2020 May 15
0
NUT -2.7.4 with Tripp Lite SMX1000 LCD on RPI4 runing 64bit ubuntu 20.04
On 5/15/20 12:13 PM, Yogesh Bhanu wrote: > [...] > # Is it possible to calculate /estimate how much time is left when on > battery ? When the UPS does not report that, you can ask nut to provide an estimate by using the runtimecal directive. For instance I have in ups.conf on a system where I use an Inform low-end UPS:         runtimecal = 120,100,480,50        
2020 May 19
0
NUT -2.7.4 with Tripp Lite SMX1000 LCD on RPI4 runing 64bit ubuntu 20.04
On 5/19/20 10:39 AM, Yogesh Bhanu wrote: > Hi Manuel et.al, > > Going thru the documentation -- it seems this configuration specific > to blazer_ups. > https://networkupstools.org/docs/man/blazer_usb.html > > Kind Regards, Other drivrs support that option as well. Here is a quote from the same config as before: [guardian]         driver = nutdrv_qx         port = auto
2020 May 20
1
NUT -2.7.4 with Tripp Lite SMX1000 LCD on RPI4 runing 64bit ubuntu 20.04
Hi Mauel, No dice. The config does not show up config: --8<-- [tripp] driver = usbhid-ups port = auto vendorid = 09ae productid = 2009 bus = 001 desc = "Tripp Lite SMX1000LCD" runtimecal = 660,100,180,50 -->8-- output: --8<-- upsc tripp Init SSL without certificate database battery.charge: 100 battery.runtime: 736 battery.type: PbAc
2020 Jun 22
0
reboot of nut managment node resets Tripplite SMX1000LCD
On Mon, 22 Jun 2020, Yogesh Bhanu wrote: > I'm not sure if it is a bug or a feature. > > I'm running Ubuntu 20.04 on my RPi4 which connects to the UPS over USB. > I have noticed whenever I reboot my RPi4. It resets the UPS ( I can > hear the relay) -- Powerloss. > Any pointers to disable this annoying bug / feature. It looks as if the shutdown part of the reboot is issuing a "delayed UPS shutdown"....
2020 Jan 09
0
nut on armhf, r-pi4b IOW
...gt; > enabled; vendor preset: enabled) > > > Active: failed (Result: protocol) since Tue 2020-01-07 07:19:19 > > > EST; 116ms ago > > > Process: 32343 ExecStart=/sbin/upsmon (code=exited, > > > status=0/SUCCESS) > > > > > > Jan 07 07:19:19 rpi4 systemd[1]: Starting Network UPS Tools - > > > power device monitor and shutdown controller... > > > Jan 07 07:19:19 rpi4 upsmon[32343]: upsmon disabled, please adjust > > > the configuration to your needs > > > Jan 07 07:19:19 rpi4 upsmon[32343]: Then set MODE t...
2020 May 19
2
NUT -2.7.4 with Tripp Lite SMX1000 LCD on RPI4 runing 64bit ubuntu 20.04
Hi Manuel et.al, Going thru the documentation -- it seems this configuration specific to blazer_ups. https://networkupstools.org/docs/man/blazer_usb.html Kind Regards, Yogesh On Fri, May 15, 2020 at 12:53 PM Manuel Wolfshant <wolfy at nobugconsulting.ro> wrote: > > On 5/15/20 12:13 PM, Yogesh Bhanu wrote: > > [...] > > # Is it possible to calculate /estimate how much
2020 Jan 12
0
nut on armhf, r-pi4b IOW
...existing cps-hid.c tables, not the generic "explore" sub-driver.) > > Attached, about 30 seconds worth > > Cheers, Gene Heskett I should add that its -wall broadcast did exactly what I wanted in the night last night: --------------------------- Broadcast message from nut at rpi4 (somewhere) (Sun Jan 12 01:15:04 2020): UPS myups at localhost on battery Broadcast message from nut at rpi4 (somewhere) (Sun Jan 12 01:15:14 2020): UPS myups at localhost on line power Broadcast message from nut at rpi4 (somewhere) (Sun Jan 12 01:54:00 2020): UPS myups at localhost on batte...
2020 May 15
4
NUT -2.7.4 with Tripp Lite SMX1000 LCD on RPI4 runing 64bit ubuntu 20.04
Hi, This is a newbie post so please bear with me. After loosing my router to a random Subminute outage. I looked around for a fanless UPS and bought Tripp Lite SMX1000LCD The above constellation works. But I have some questions about outputs. Please see attache nut report for the config. upsc output: --8<-- fourpi01:~# upsc tripp Init SSL without certificate database battery.charge: 100
2020 Jun 22
2
Low Battery Problems
...rles Lepple wrote: > > On Jun 18, 2020, at 12:39 PM, Mike Dillinger wrote: > > > > ups.test.result: No test initiated > > I’d recommend a battery test. Starting the test via the front panel > should be sufficient, or you might be able to do it with upscmd. from man pi at rpi4:~ $ upscmd -l myups Instant commands supported on UPS [myups]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obsolete (use beeper.disable or beeper.mute) beeper.on - Obsolete (use beeper.enable) load.off - T...
2023 May 22
1
got nut 2.8.1 but despite reinstall, shows 2.7.4
...h to get > the new version actually running? I still get - -V=2.7.4 The UPGRADING file tsalks about a 2.8.1, but I have started with the autogen 3 times in the usual sequence, winding up with 2.7.4 twice, and while the third time is supposed yo be a charm, now it won't run at all. pi at rpi4:/etc/nut $ sudo /etc/init.d/nut-server restart [ ok ] Restarting nut-server (via systemctl): nut-server.service. You have new mail in /var/mail/pi pi at rpi4:/etc/nut $ sudo /etc/init.d/nut-server status ? nut-server.service - Network UPS Tools - power devices information server Loaded: loaded...
2020 Oct 26
2
Can't get CyberPower UPS to work with Raspberry Pi 4
...oaded > > active running Network UPS Tools - power device monitor and > > shutdown controller nut-server.service loaded active running > > Network UPS Tools - power devices information server > I think it may be dependent on thhe ups. I have a 625 WA cyberpower on an rpi4, and I believe its more truthfull. Is this helpfull? pi at rpi4:/media/pi/workspace $ upsc myups Init SSL without certificate database battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 20 battery.mfr.date: CPS battery.runtime: 4410 battery.runtime.low: 300 battery.type: PbAcid bat...
2019 Dec 26
2
aarch64 vm doesn't boots
Greetings, I'm trying to bring up a alpine rpi aarch64 image within kvm but I'm ended up with a stuck system, here is the xml: <domain type='qemu'> <name>alpine_rpi4_dev_machine</name> <uuid>b1b155fc-cb92-4f22-8904-c934dd24415b</uuid> <memory unit='KiB'>4194304</memory> <currentMemory unit='KiB'>4194304</currentMemory> <vcpu placement='static'>4</vcpu> <os> <typ...