Displaying 11 results from an estimated 11 matches for "rfc1628".
2013 May 08
0
My nut-snmp has forgotten how to speak IETF RFC1628!
...this, but I
didn't find anyone else having this issue.]
Has anyone seen this before? I'm almost 100% certain I tested this
nut correctly detected OB LB in the past, but when I happened to look
at it today, I see it refusing to work -- apparently because the NUT
client knows how to ask for RFC1628 OIDs, but not what to do with the
responses. WTF!
# /lib/nut/snmp-ups -a GE-EP3000 -DDDDDDDDD
Network UPS Tools - Generic SNMP UPS driver 0.47 (2.4.3)
0.000000 debug level is '9'
0.001846 SNMP UPS driver : entering upsdrv_initups()
0.001860 SNMP UP...
2012 Apr 24
4
Riello UPs implementation for NUT software
...t our UPS to NUT.
For this porpoise we will provide to you all the information requested as serial protocols, end even some ups in case.
We have 2 way to communicate with our ups via RS232 and USB (with our driver, but the source code will be provided in case) and via TCP/IP over SNMP protocol with RFC1628.
Thank you in advance and I hope to receive an answer soon.
Best regards.
Massimo Zampieri
Technical Marketing - UPS Software Product Manager
RPS SpA
Viale Europa, 7
37045 Legnago (VR)
Tel. +39 0442 635807 - Fax. +39 0442 635107 - Mobile: +39 335 7170247
Skype Id: massimozampieri - VoIp:
E-m...
2006 Aug 03
2
Connectiion to UPS via SNMP
Hi NUT-Users,
we work with a GE LP 33 UPS and an Advanced SNMP WEB Interface Card. This card supports the RFC1628 Definition.
So I think this combination work together with NUT and the snmp-driver, correct?
I installed the networkupstools on my Debian Sarge with apt-get (nut & nut-snmp).
After configuration I start the upsd and upsmon. I get following output in /var/log/syslog:
...
Aug 3 08:40:44 localh...
2020 Mar 25
2
[EXTERNAL] thoughts on tripp lite Smart Online UPSs?
Thanks. I haven't used that unit specifically with Network UPS Tools, but have used similar (from a protocol perspective) units.
I'm working remotely for a while, but on the off chance I get into the position to connect a unit via USB, what Operating System are you using?
If the opportunity arises, I can try to set up a basic test.
Thank you,
David Zomaya
Business/Quality Analyst-
2005 Sep 12
0
GE LanPro + SNMP + NUT
...ns or projects mention it. NUT doesn't even list it
in its compatibility lists. Maybe its sold under different name in some
marketareas?
The system we have comes with a serial connection and an SNMP interface
card is available for a very reasonable price. The card is said to be
compatible with RFC1628 UPS-MIBS. A network-enabled generic protocol
could just be the thing we're looking for, especially if GE is not
supported by NUT's generic drivers. The idea of using SNMP is also
appealing when thinking about hooking up appliances.
Would anybody like to share their experiences and views on...
2014 Aug 11
0
Meaning of Battery Resting/PW-MIBs
..._INPUT_1, NULL },
Must get ".1" there, as it is in output.voltage/current. (The input
current isn't returned, but I think it should be right with .1 there...)
TestBattery misses the .0 at the end:
#define PW_OID_BATTEST_START "1.3.6.1.4.1.534.1.8.1.0"
And by the way, the RFC1628-way of initiating tests works (by hand using
snmpget [SpinLock]/snmpset) with this ups, too.
And I took the ups status from ietf:
{ "ups.status", ST_FLAG_STRING, SU_INFOSIZE, IETF_OID_POWER_STATUS, "OFF",
SU_STATUS_PWR, &ietf_pwr_info[0] },
because 1.3.6.1.4...
2015 May 28
4
upsmon and Chloride UPS
Hi,
We have 2 UPS Chloride 80 NET 120 ( a black and white one ) in our
datacenter.
Could you please tell me if it is possible to use upsmon or other free
solution with these two UPS for shuting down servers during electrical lost
power before battery crash
.
Beet regards,
Roger
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
2009 Jul 26
4
Any word on when the ietf mib will be fixed for liebert?
This mib used to work, so is there a way to go back to the version
prior to this one without downgrading the whole package?
* Starting UPS drivers...
Network UPS Tools - UPS driver controller 2.4.1
Network UPS Tools - Generic SNMP UPS driver 0.44 (2.4.1)
Detected GXT2-2000RT120 on host upswallleft (mib: ietf 1.3)
[upswallleft] nut_snmp_get: 1.3.6.1.2.1.33.1.4.4.1.4.0: Error in
2012 Jun 10
3
SNMP agent for NUT
Hello guys,
I was some years ago when I sent something to this list.
NUT is a great tool but lacks SNMP management. It can access a device using SNMP
but I found no way to read NUT values using SNMP. It would be very
useful in order to integrate with
network management software based on SNMP. As I did not find a
solution, I wrote it myself.
I wrote a MIB file and a SNMP agent for net-snmp
2012 Jun 10
3
SNMP agent for NUT
Hello guys,
I was some years ago when I sent something to this list.
NUT is a great tool but lacks SNMP management. It can access a device using SNMP
but I found no way to read NUT values using SNMP. It would be very
useful in order to integrate with
network management software based on SNMP. As I did not find a
solution, I wrote it myself.
I wrote a MIB file and a SNMP agent for net-snmp
2009 Mar 28
1
APCUPSD port 3551 permission problem
...uot;APC", "APC_NOTRAP"
# or "RFC" where APC is the powernet MIB,
# "APC_NOTRAP" is powernet with SNMP trap
# catching disabled, and RFC is the IETF's
# rfc1628 UPS-MIB. You usually want "APC".
# Port is usually 161. Community is usually
# "private".
#
# dumb /dev/tty** Old serial character device for use
# with simple-signaling UPSes.
#
# pcnet...