search for: remainingcapac

Displaying 20 results from an estimated 94 matches for "remainingcapac".

2023 Nov 15
1
What is the arduino sub-driver intended to be used for?
You have the device side right. Devices have "UPS.PowerSummary.CapacityMode" (are the next three in %, mAh, or mWh? "UPS.PowerSummary.FullChargeCapacity" "UPS.PowerSummary.RemainingCapacity" "UPS.PowerSummary.RemainingCapacityLimit" "UPS.PowerSummary.WarningCapacityLimit" According to nut-names.txt, NUT has: battery.charge | Battery charge (percent) | 100.0 battery.charge.low | Remaining battery level when UPS switches to LB...
2023 Nov 15
1
What is the arduino sub-driver intended to be used for?
...rcent (%) > 3: Boolean support only (OK or failed) > > Grep'ing the source, nothing makes use of this now (some subdrivers have it > mapped to unmapped.ups.powersummary.capacitymode or something similar) and > many of the HID UPS drivers assume CapacityMode 2 (they interpret > RemainingCapacity, WarningCapacityLimit, RemainingCapacityLimit as > percent). My application (and the original sample sketch for the Arduino > project also does this, so I'm fine with that. > > But, I was wondering if anyone could point out the right way in a NUT > subdriver to have a function...
2006 Aug 07
0
Re: your Tripp-Lite AVR550U
...oltage, Type: Feature, Value: 120.000000 > Path: UPS.PowerSummary.AudibleAlarmControl, Type: Feature, Value: 2.000000 > Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, Value: 24.000000 > Path: UPS.PowerSummary.CapacityMode, Type: Feature, Value: 2.000000 > Path: UPS.PowerSummary.RemainingCapacity, Type: Input, Value: 100.000000 > Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, Value: 100.000000 > Path: UPS.PowerSummary.FullChargeCapacity, Type: Feature, Value: 100.000000 > Path: UPS.PowerSummary.PresentStatus.ShutdownImminent, Type: Input, > Value: 0.000000 > Can...
2006 Jul 08
1
Re: your Tripp-Lite AVR550U
...oltage, Type: Feature, Value: 120.000000 > Path: UPS.PowerSummary.AudibleAlarmControl, Type: Feature, Value: 2.000000 > Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, Value: 24.000000 > Path: UPS.PowerSummary.CapacityMode, Type: Feature, Value: 2.000000 > Path: UPS.PowerSummary.RemainingCapacity, Type: Input, Value: 100.000000 > Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, Value: 100.000000 > Path: UPS.PowerSummary.FullChargeCapacity, Type: Feature, Value: 100.000000 > Path: UPS.PowerSummary.PresentStatus.ShutdownImminent, Type: Input, > Value: 0.000000 > Can...
2005 Aug 29
1
Belkin and newhidups
...e: 2 zzz.ups.powersummary.configvoltage: 12 zzz.ups.powersummary.current: 0 zzz.ups.powersummary.designcapacity: 100 zzz.ups.powersummary.fullchargecapacity: 100 zzz.ups.powersummary.ioeminformation: Belkin zzz.ups.powersummary.iproduct: UPS zzz.ups.powersummary.rechargeable: 1 zzz.ups.powersummary.remainingcapacity: 100 zzz.ups.powersummary.voltage: 136 It seems the ups.status doesn't show OL here, I tried unplugging the UPS from the outlet and after a few seconds it shows it as OB Discharging so we know its updating the values, the same goes with the remaining capacity and runtime (they decrease w...
2005 Aug 02
0
newhidups for APC Back-UPS ES 650
...rSummary.Rechargeable Path: UPS.PowerSummary.APCStatusFlag Path: UPS.PowerSummary.APCStatusFlag Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.ConfigVoltage Path: UPS.PowerSummary.Voltage Path: UPS.PowerSummary.iManufacturer Path: UPS.PowerSummary.CapacityMode Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.DesignCapacity Path: UPS.PowerSummary.FullChargeCapacity Path: UPS.PowerSummary.WarningCapacityLimit Path: UPS.PowerSummary.CapacityGranularity2 Path: UPS.P...
2023 Nov 15
2
What is the arduino sub-driver intended to be used for?
...lues are: 0: maH 1: mwH 2: percent (%) 3: Boolean support only (OK or failed) Grep'ing the source, nothing makes use of this now (some subdrivers have it mapped to unmapped.ups.powersummary.capacitymode or something similar) and many of the HID UPS drivers assume CapacityMode 2 (they interpret RemainingCapacity, WarningCapacityLimit, RemainingCapacityLimit as percent). My application (and the original sample sketch for the Arduino project also does this, so I'm fine with that. But, I was wondering if anyone could point out the right way in a NUT subdriver to have a function that handles RemainingC...
2017 Apr 17
1
New UPS information - Liebert GXT4 via US
...ReportID: 0x03, Offset: 24, Size: 2, Value: 2 0.008448 Path: UPS.PowerSummary.Rechargeable, Type: Feature, ReportID: 0x03, Offset: 26, Size: 1, Value: 1 0.008480 Path: UPS.PowerSummary.Undefined, Type: Feature, ReportID: 0x03, Offset: 27, Size: 5, Value: 1 0.008638 Path: UPS.PowerSummary.RemainingCapacityLimit, Type: Feature, ReportID: 0x13, Offset: 0, Size: 8, Value: 20 0.008892 Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, ReportID: 0x06, Offset: 0, Size: 8, Value: 100 0.008921 Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x06, Offset: 0, Size: 8, Value: 100...
2008 Jan 26
1
USBDEVFS_CONTROL error ?
...th: UPS.PowerSummary.iDeviceChemistry, Type: Feature, ReportID: 0x2a, Offset: 0, Size: 8, Value: 24.000000 Report[r]: (2 bytes) => 33 02 Path: UPS.PowerSummary.CapacityMode, Type: Feature, ReportID: 0x33, Offset: 0, Size: 8, Value: 2.000000 Report[r]: (2 bytes) => 34 64 Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x34, Offset: 0, Size: 8, Value: 100.000000 Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, ReportID: 0x34, Offset: 0, Size: 8, Value: 100.000000 Report[r]: (2 bytes) => 37 64 Path: UPS.PowerSummary.FullChargeCapacity, Type: Feature, ReportID: 0x37, Offset: 0,...
2007 Feb 26
1
Tripp Lite USB UPS
...th: UPS.PowerSummary.iOEMInformation, Type: Feature, ReportID: 0x62, Offset: 0, Size: 8, Value: 4.000000 Report[r]: (2 bytes) => 33 02 Path: UPS.PowerSummary.CapacityMode, Type: Feature, ReportID: 0x33, Offset: 0, Size: 8, Value: 2.000000 Report[r]: (2 bytes) => 34 5e Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x34, Offset: 0, Size: 8, Value: 94.000000 Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, ReportID: 0x34, Offset: 0, Size: 8, Value: 94.000000 Report[r]: (2 bytes) => 3a 19 Path: UPS.PowerSummary.RemainingCapacityLimit, Type: Feature, ReportID: 0x3a, Offse...
2014 Apr 05
0
I can't make changes to ups.delay.shutdown to stick
On Apr 5, 2014, at 7:18 AM, Mick wrote: > $ upsrw -s "ups.delay.shutdown"="30" iDowell at localhost > Username (suzy): admin > Password: > OK This command is sending the value to the UPS (via the usbhid-ups driver). > $ upsc iDowell at localhost ups.delay.shutdown > 30 And this command ends up reading the value back from the UPS. > However, following
2006 Nov 11
1
Help with newhidups subdriver for Dynex UPS
...signCapacity, Type: Feature, Value: 100.000000 Path: UPS.PowerSummary.CapacityGranularity1, Type: Feature, Value: 5.000000 Path: UPS.PowerSummary.CapacityGranularity2, Type: Feature, Value: 10.000000 Path: UPS.PowerSummary.WarningCapacityLimit, Type: Feature, Value: 20.000000 Path: UPS.PowerSummary.RemainingCapacityLimit, Type: Feature, Value: 10.000000 Path: UPS.PowerSummary.FullChargeCapacity, Type: Feature, Value: 100.000000 Path: UPS.PowerSummary.RemainingCapacity, Type: Input, Value: 120.000000 Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, Value: 120.000000 Path: UPS.PowerSummary.RunTimeToEm...
2014 Apr 05
2
I can't make changes to ups.delay.shutdown to stick
...e, ReportID: 0x0b, Offset: 24, Size: 8, Value: 0 0.982876 Path: UPS.PowerSummary.FlowID, Type: Feature, ReportID: 0x0b, Offset: 32, Size: 8, Value: 0 0.986836 Path: UPS.PowerSummary.CapacityMode, Type: Feature, ReportID: 0x0c, Offset: 0, Size: 8, Value: 2 0.986861 Path: UPS.PowerSummary.RemainingCapacityLimit, Type: Feature, ReportID: 0x0c, Offset: 8, Size: 8, Value: 15 0.986878 Path: UPS.PowerSummary.CapacityGranularity1, Type: Feature, ReportID: 0x0c, Offset: 16, Size: 8, Value: 25 0.990825 Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, ReportID: 0x10, Offset: 0, Size: 8, Val...
2017 Feb 17
0
EATON 9SX not display battery.charge
...==2 is %. But since CapacityMode is in > UPS.PowerSummary, maybe it refers to UPS.PowerSummary.DesignCapacity instead. > The 18000 might be mAh or mWh. > > It is also possible that one of UPS.PowerSummary.DesignCapacity > or UPS.PowerSummary.FullChargeCapacity was intended to > be RemainingCapacity. You can verify this by forcing the UPS onto battery > power until the front panel displays a charge lower than 100%. > > I do not see any items which are likely to be runtime. > Charles' audit is fully right. After some more review and local testing: - would you be able to tes...
2014 Apr 05
2
I can't make changes to ups.delay.shutdown to stick
Hi All, I'm using an iDowell UPS with the usbhid-ups driver: $ upsc iDowell at localhost battery.charge: 100 battery.charge.low: 15 battery.runtime: 650 battery.type: Pb acc device.mfr: iDowell device.model: iBox device.serial: 00000001 device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto
2005 Aug 26
0
NUT patches
...rSummary.Rechargeable Path: UPS.PowerSummary.APCStatusFlag Path: UPS.PowerSummary.APCStatusFlag Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.ConfigVoltage Path: UPS.PowerSummary.Voltage Path: UPS.PowerSummary.iManufacturer Path: UPS.PowerSummary.CapacityMode Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.DesignCapacity Path: UPS.PowerSummary.FullChargeCapacity Path: UPS.PowerSummary.WarningCapacityLimit Path: UPS.PowerSummary.CapacityGranularity2 Path: UPS.P...
2017 Oct 17
0
Junda-tech
...quot;, 0, 0, > "UPS.PowerSummary.PresentStatus.Discharging", NULL, "%.0f", 0, NULL }, > { "unmapped.ups.powersummary.rechargeable", 0, 0, > "UPS.PowerSummary.Rechargeable", NULL, "%.0f", 0, NULL }, > { "unmapped.ups.powersummary.remainingcapacity", 0, 0, > "UPS.PowerSummary.RemainingCapacity", NULL, "%.0f", 0, NULL }, > { "unmapped.ups.powersummary.imanufacturer", 0, 0, > "UPS.PowerSummary.iManufacturer", NULL, "%.0f", 0, NULL }, > { "unmapped.ups.powersummary.ip...
2005 Oct 04
0
Problems connecting to APC/Smart-UPS 3000 RM
...alNumber Path: UPS.PowerSummary.iManufacturer Path: UPS.PowerSummary.iOEMInformation Path: UPS.PowerSummary.iDeviceChemistry Path: UPS.PowerSummary.Rechargeable Path: UPS.PowerSummary.CapacityMode Path: UPS.PowerSummary.DesignCapacity Path: UPS.PowerSummary.FullChargeCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.CapacityGranularity1 Path: UPS.PowerSummary.CapacityGranularity2 Path: UPS.PowerSummary.WarningCapacityLimit Path: UPS.PowerSummary.RemainingCapacityLimit Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.RunTimeToEmpty...
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
..., Size: 16, Value: 12.59 > 0.035776 Path: UPS.PowerSummary.iManufacturer, Type: Feature, ReportID: 0x0a, Offset: 0, Size: 8, Value: 1 > 0.037025 Path: UPS.PowerSummary.CapacityMode, Type: Feature, ReportID: 0x0b, Offset: 0, Size: 8, Value: 2 > 0.038282 Path: UPS.PowerSummary.RemainingCapacity, Type: Input, ReportID: 0x0c, Offset: 0, Size: 8, Value: 18 > 0.039169 Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, ReportID: 0x0c, Offset: 0, Size: 8, Value: 18 > 0.040008 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x0c, Offset: 8, Size: 16, Value:...
2005 Jul 22
1
Another HID USB UPS
...rSummary.Rechargeable Path: UPS.PowerSummary.APCStatusFlag Path: UPS.PowerSummary.APCStatusFlag Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.ConfigVoltage Path: UPS.PowerSummary.Voltage Path: UPS.PowerSummary.iManufacturer Path: UPS.PowerSummary.CapacityMode Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.DesignCapacity Path: UPS.PowerSummary.FullChargeCapacity Path: UPS.PowerSummary.WarningCapacityLimit Path: UPS.PowerSummary.CapacityGranularity2 Path: UPS.P...