Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
...are of. We would have had to accidentally change 23 of them ? >> >> Thanks, >> >> Kelly >> >> On 2016-05-25, 1:25 PM, "Kelly Lesperance" <klesperance at blackberry.com> wrote: >> >>> They are: >>> >>> [root at r1k1 ~] # hdparm -I /dev/sda >>> >>> /dev/sda: >>> >>> ATA device, with non-removable media >>> Model Number: MB4000GCWDC >>> Serial Number: S1Z06RW9 >>> Firmware Revision: HPGD &gt...
2016 May 25
3
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
...oads for the SAS2308, so I think > I?m out of luck wrt MegaRAID. > > Bounced the node, confirmed MPT Firmware 15.10.09.00-IT. > HP Driver is v 15.10.04.00. > > Both are the latest from HP. > > Unsure why, but the module itself reports version 20.100.00.00: > > [root at r1k1 sys] # cat module/mpt2sas/version > 20.100.00.00 Suggestion: if these are new, they're under warranty, and it's a hardware issue. Call HP tech support and open a ticket with them - they might have an answer. mark
2016 May 25
1
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
On 2016-05-25 19:13, Kelly Lesperance wrote: > Hdparm didn?t get far: > > [root at r1k1 ~] # hdparm -tT /dev/sda > > /dev/sda: > Timing cached reads: Alarm clock > [root at r1k1 ~] # Hi Kelly, Try running 'iostat -xdmc 1'. Look for a single drive that has substantially greater await than ~10msec. If all the drives except one are taking 6-8msec, but one is ve...
2016 May 25
0
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
Hdparm didn?t get far: [root at r1k1 ~] # hdparm -tT /dev/sda /dev/sda: Timing cached reads: Alarm clock [root at r1k1 ~] # On 2016-05-25, 2:44 PM, "Kelly Lesperance" <klesperance at blackberry.com> wrote: >The HBA is an HP H220. > >We haven?t really benchmarked individual drives ? all 12 drives are util...
2016 May 25
2
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
[merging] The HBA the drives are attached to has no configuration that I?m aware of. We would have had to accidentally change 23 of them ? Thanks, Kelly On 2016-05-25, 1:25 PM, "Kelly Lesperance" <klesperance at blackberry.com> wrote: >They are: > >[root at r1k1 ~] # hdparm -I /dev/sda > >/dev/sda: > >ATA device, with non-removable media > Model Number: MB4000GCWDC > Serial Number: S1Z06RW9 > Firmware Revision: HPGD > Transport: Serial, SATA Rev 3.0 > >Thanks, &...
2016 May 25
3
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
John R Pierce wrote: > On 5/25/2016 11:44 AM, Kelly Lesperance wrote: >> The HBA is an HP H220. > > OH. its a very good idea to verify the driver is at the same revision > level as the firmware. not 100% sure how you do this under CentOS, my > H220 system is running FreeBSD, and is at revision P20, both firmware > and driver. HP's firmware, at least what I
2016 May 25
6
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
...t fairly fast (20000K/sec - the limit that's been set), but then quickly drops down to about 4000K/Sec. dev.raid.speed sysctls are at the defaults: dev.raid.speed_limit_max = 200000 dev.raid.speed_limit_min = 1000 Here's 10 seconds of iostat output, which illustrates the issue: [root at r1k1log] # iostat 1 10 Linux 3.10.0-327.18.2.el7.x86_64 (r1k1) ? ?05/24/16 ? ?_x86_64_? ?(32 CPU) avg-cpu:? %user? ?%nice %system %iowait? %steal? ?%idle ? ? ? ? ? ?8.80? ? 0.06? ? 1.89? ?14.79? ? 0.00? ?74.46 Device:? ? ? ? ? ? tps? ? kB_read/s? ? kB_wrtn/s? ? kB_read? ? kB_wrtn sda? ? ? ? ? ? ? 52.5...
2016 May 25
0
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
...ched to has no configuration that I?m aware of. We would have had to accidentally change 23 of them ? > > Thanks, > > Kelly > > On 2016-05-25, 1:25 PM, "Kelly Lesperance" <klesperance at blackberry.com> wrote: > >> They are: >> >> [root at r1k1 ~] # hdparm -I /dev/sda >> >> /dev/sda: >> >> ATA device, with non-removable media >> Model Number: MB4000GCWDC >> Serial Number: S1Z06RW9 >> Firmware Revision: HPGD >> Transport: S...
2016 May 25
0
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
LSI/Avago?s web pages don?t have any downloads for the SAS2308, so I think I?m out of luck wrt MegaRAID. Bounced the node, confirmed MPT Firmware 15.10.09.00-IT. HP Driver is v 15.10.04.00. Both are the latest from HP. Unsure why, but the module itself reports version 20.100.00.00: [root at r1k1 sys] # cat module/mpt2sas/version 20.100.00.00 On 2016-05-25, 3:20 PM, "centos-bounces at centos.org on behalf of m.roth at 5-cent.us" <centos-bounces at centos.org on behalf of m.roth at 5-cent.us> wrote: >John R Pierce wrote: >> On 5/25/2016 11:44 AM, Kelly Lesperance...
2016 May 25
0
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
...; I?m out of luck wrt MegaRAID. >> >> Bounced the node, confirmed MPT Firmware 15.10.09.00-IT. >> HP Driver is v 15.10.04.00. >> >> Both are the latest from HP. >> >> Unsure why, but the module itself reports version 20.100.00.00: >> >> [root at r1k1 sys] # cat module/mpt2sas/version >> 20.100.00.00 > >Suggestion: if these are new, they're under warranty, and it's a hardware >issue. Call HP tech support and open a ticket with them - they might have >an answer. > > mark > >_______________________________...