search for: r118

Displaying 5 results from an estimated 5 matches for "r118".

Did you mean: r11
2005 Aug 09
0
How to lower float charge voltage of an APC Smart UPS - corrected
...ngerous, but it does work. 2) Unplug the UPS, Disconnect and remove the batteries, press the ON button, and wait five minutes for internal voltages to bleed off. 3) Remove the cover from the UPS and remove the plastic sheet which covers the circuit board. 4) Locate the 100K ohm resistor labelled R118. You have found the right resistor if one end of it connects to pin 13 of the intergrated circuit labelled APC2020. This is the sense resistor for the battery float charge voltage regulator. 5) Solder a 1.3M ohm resistor in parallel with R118, to lower the resistance by a few percent. Now the floa...
2010 Jun 15
0
[LLVMdev] Question on X86 backend
...2, R63, R64, R65, R66, R67, R68, R69, R70, R71, R72, R73, R74, R75, R76, R77, R78, R79, R80, R81, R82, R83, R84, R85, R86, R87, R88, R89, R90, R91, R92, R93, R94, R95, R96, R97, R98, R99, R100, R101, R102, R103, R104, R105, R106, R107, R108, R109, R110, R111, R112, R113, R114, R115, R116, R117, R118, R119, R120, R121, R122, R123, R124, R125, R126, R127, R128, R129, R130, R131, R132, R133, R134, R135, R136, R137, R138, R139, R140, R141, R142, R143, R144, R145, R146, R147, R148, R149, R150, R151, R152, R153, R154, R155, R156, R157, R158, R159, R160, R161, R162, R163, R164, R165, R166, R167, R...
2010 Jun 15
2
[LLVMdev] Question on X86 backend
Hi Micah, > In X86InstrInfo.td for Call Instructions, it mentions that Uses for > argument registers are added manually. Can someone point me to the > location where they are added as the comment doesn't reference a > where or how? the register uses are added by the function X86TargetLowering::LowerCall() during the DAG Lowering phase. This is the relevant code segment: // Add
2005 Aug 09
0
How to lower float charge voltage of an APC Smart UPS unit
...s, but it does work. 2) Unplug the UPS, Disconnect and remove the batteries, press the ON button, and wait five minutes for all internal voltages to bleed off. 3) Remove the cover from the UPS and remove the plastic sheet which covers the circuit board. 4) Locate the 100K ohm resistor labelled R118. You have found the right resistor if one end of it connects to pin 14 of the intergrated circuit labelled APC2020. This is the sense resistor for the battery float charge voltage regulator. 5) Solder a 1.3M ohm resistor in parallel with R110, to lower the resistance by a few percent. Now the...
2015 Jun 07
43
[Bug 90887] New: PhiMovesPass in register allocator broken
https://bugs.freedesktop.org/show_bug.cgi?id=90887 Bug ID: 90887 Summary: PhiMovesPass in register allocator broken Product: Mesa Version: git Hardware: All OS: All Status: NEW Severity: normal Priority: medium Component: Drivers/DRI/nouveau Assignee: nouveau at