search for: pw5125

Displaying 20 results from an estimated 21 matches for "pw5125".

2013 Jun 29
2
upsrw doesn't set variable
NUT 2.6.5 on FreeBSD 9.1 Why isn't the variable outlet.1.delay.shutdown set with the following command? # upsc PW5125 at localhost | grep "outlet.1.delay.shutdown" outlet.1.delay.shutdown: -1 # upsrw -u au -p ap -s outlet.1.delay.shutdown PW5125 at localhost Enter new value for outlet.1.delay.shutdown: 10 OK # upsc PW5125 at localhost | grep "outlet.1.delay.shutdown" outlet.1.delay.shutdown:...
2009 Jun 20
1
upsmon says ONBATT when status: TRIM
Hi, I've been getting emails from upsmon saying: Subject: UPS PW5125 at localhost notification: ONBATT UPS PW5125 at localhost on battery But then the machines on the UPS stay on for hours; we haven't got that kind of runtime, more like 10-20 minutes. After a few occurrences, it now happened at a time where I could log in to see in real time what is happenin...
2013 Jun 29
0
upsrw doesn't set variable
On 6/29/2013 at 9:14 AM Mike. wrote: |NUT 2.6.5 on FreeBSD 9.1 | | |Why isn't the variable outlet.1.delay.shutdown set with the following |command? | | | |# upsc PW5125 at localhost | grep "outlet.1.delay.shutdown" |outlet.1.delay.shutdown: -1 | |# upsrw -u au -p ap -s outlet.1.delay.shutdown PW5125 at localhost |Enter new value for outlet.1.delay.shutdown: 10 |OK | |# upsc PW5125 at localhost | grep "outlet.1.delay.shutdown" |outlet.1.delay.sh...
2013 Jun 29
3
upsrw doesn't set variable
On Jun 29, 2013, at 9:45 AM, Mike. wrote: > On 6/29/2013 at 9:14 AM Mike. wrote: > > |NUT 2.6.5 on FreeBSD 9.1 > | > | > |Why isn't the variable outlet.1.delay.shutdown set with the following > |command? > | > | > | > |# upsc PW5125 at localhost | grep "outlet.1.delay.shutdown" > |outlet.1.delay.shutdown: -1 > | > |# upsrw -u au -p ap -s outlet.1.delay.shutdown PW5125 at localhost > |Enter new value for outlet.1.delay.shutdown: 10 > |OK > | > |# upsc PW5125 at localhost | grep "outlet.1.dela...
2017 Feb 20
2
[HCL] Powerware PW5125 with driver bcmxcp
This UPS is already listed in the compatibility list. But I wanted to add the instant commands supported by upscmd: ============================ Instant commands supported on UPS [PW5125]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper load.on - Turn on the load immediately outlet.1.load.off - Turn off the load on outlet 1 immediately outlet.1.load.on - Turn on the load on outlet 1 immediately outlet.1.sh...
2017 Feb 21
1
[HCL] Powerware PW5125 with driver bcmxcp
...upscmd output here: > > http://networkupstools.org/stable-hcl.html#footnotes > > Let us know if there is another place we should update. > > To get an idea of the age of the unit, is this a pre-merger Powerware, or is it also labeled Eaton? > > Given the age of the other PW5125 entries, can you please send upsc (and upsrw) output as well? Feel free to mask portions of the serial number, but at least for other vendors, the first few characters can be useful for identifying differences in the underlying implementation. Hopefully the ups.firmware value is sufficient. > &...
2017 Feb 21
0
[HCL] Powerware PW5125 with driver bcmxcp
...reed, and we do ask for upsc, upsrw and upscmd output here: http://networkupstools.org/stable-hcl.html#footnotes Let us know if there is another place we should update. To get an idea of the age of the unit, is this a pre-merger Powerware, or is it also labeled Eaton? Given the age of the other PW5125 entries, can you please send upsc (and upsrw) output as well? Feel free to mask portions of the serial number, but at least for other vendors, the first few characters can be useful for identifying differences in the underlying implementation. Hopefully the ups.firmware value is sufficient. Thanks...
2008 Dec 21
1
upsd segfault.
Hi all, Have a strange behaviour that I don't know how to debug. This is when I use the Eaton PW5125 ups. I have it connected And running in standby. Starting up the drivers (pw3105 and pw5125) and they run. Start up the upsd and can read info from both of them. The 3105 is supplying the computer and the 5125 have a dummy load. The 5125 is showing that it is off line. Now when I hit the on line...
2013 Jun 29
0
upsrw doesn't set variable
...harles Lepple wrote: |On Jun 29, 2013, at 9:45 AM, Mike. wrote: | |> On 6/29/2013 at 9:14 AM Mike. wrote: |> |> |NUT 2.6.5 on FreeBSD 9.1 |> | |> | |> |Why isn't the variable outlet.1.delay.shutdown set with the following |> |command? |> | |> | |> | |> |# upsc PW5125 at localhost | grep "outlet.1.delay.shutdown" |> |outlet.1.delay.shutdown: -1 |> | |> |# upsrw -u au -p ap -s outlet.1.delay.shutdown PW5125 at localhost |> |Enter new value for outlet.1.delay.shutdown: 10 |> |OK |> | |> |# upsc PW5125 at localhost | grep "outlet...
2013 Jun 29
1
upsrw doesn't set variable
...utlets: 2 > > 16.658358 Number of bytes: 6 > > 16.658369 Outlet number: 1 > 8<---------------snip------------ The problem is that I had a crash on my backup ;-( so I lost the paper on the specific commands for 5125. So if someone have the command specifications on pw5125, can you check if this is the case for the 5125 that it is impossible to set auto off delay. Regards Kjell Claesson Co author of the bcmxcp driver.
2013 Jun 29
2
upsrw doesn't set variable
...i Mike, > > Thanks for the quick reply. > > I checked the log file (which, admittedly, I should have done before I > posted about the problem :) ). > > Here's the command and the corresponding log message: > > # upsrw -u au -p ap -s outlet.1.delay.shutdown=12 PW5125 at localhost > OK > > bcmxcp[90004]: Set [outlet.1.delay.shutdown 12] failed due to invalid > parameter > Yep the ups is telling that the command has an invalid parameter. Have to check if there is any difference between the 5125 and others. > > Curious that the comman...
2013 Feb 21
1
NUT with Powerware 5125.
Hi, Does anyone know how to make NUT works with Powerware 5125? I already tried serial communication (genericups and bcmxcp) and USB (usbhid-ups and bcmxcp_usb), but without success. I'm using the latest version of NUT (2.6.5) under Debian amd64. Can anyone help me? Thanks. Daniel -------------- next part -------------- An HTML attachment was scrubbed... URL:
2007 Apr 06
3
questions re. patching bcmxcp.c and choosing variable names
I've patched bcmxcp.c such that it can power cycle the outlet load segments independently on a Powerware PW5125 UPS. I presume that it will work for any XCP protocol UPS with 2 load segments. Should these instant commands be called outlet.1.shutdown.return outlet.2.shutdown.return ? Where do the descriptions displayed by upscmd -l come from? Presently it shows outlet.1.shutdown.return - Unavailable out...
2007 Sep 19
1
Programming problem.
...PS_TOP_DATA_REQ 8a <-- PW_LOAD_OFF_RESTART 8b <-- PW_UPS_OFF a0 <-- PW_SET_REQ_ONLY_MODE cf <-- Autorisation command So this ups does not need to list unused functions like: batt_test sys_test set_config set_outlet e.t.c when you ask for possible commands. But if you connect a PW5125 it have all the commands listed in bcmxcp.h. It should be some more listed in the bcmxcp.h, like 0x32 (event history block). My plan was to use a struct and load it with the commands. Then loop it and set a bool in the struct if it is present or not. That could be done, but..........? Then it is...
2013 Jun 29
0
upsrw doesn't set variable
...|> |> Thanks for the quick reply. |> |> I checked the log file (which, admittedly, I should have done before I |> posted about the problem :) ). |> |> Here's the command and the corresponding log message: |> |> # upsrw -u au -p ap -s outlet.1.delay.shutdown=12 PW5125 at localhost |> OK |> |> bcmxcp[90004]: Set [outlet.1.delay.shutdown 12] failed due to invalid |> parameter |> |Yep the ups is telling that the command has an invalid parameter. |Have to check if there is any difference between the 5125 and others. |> |> Curious that t...
2009 Aug 27
2
Serial comm errors with bcmxcp on HP R3000 XR
I have setup nut-2.4.1 with the bcmxcp driver for my HP R3000 XR unit and although it appears to work, I receive the following sorts of errors in syslog: Aug 27 10:33:05 sv18 bcmxcp[6373]: Communications with UPS lost: Receive error (data): got 0 bytes instead of 64!!! Aug 27 10:33:15 sv18 bcmxcp[6373]: Communications with UPS lost: Receive error (data): got 0 bytes instead of 64!!! Aug 27
2007 Nov 30
0
which driver for Powerware 5125
Hello, I have a Powerware 5125 UPS and I don't know which driver I should use. In the compatibility list for the stable branch I see 2 sections for this model: 5119, 5125 - genericups upstype=15 PW5125 - bcmxcp Why are there 2 and which should I use? Thank you.
2007 Jul 10
1
[nut-commits] svn commit r1019 - in trunk: . drivers
..... 2007/7/9, Kjell Claesson <keyson-guest at alioth.debian.org>: > Author: keyson-guest > Date: Mon Jul 9 19:48:51 2007 > New Revision: 1019 > > Log: > Patch from Oliver Wilcock - bcmxcp.c modified to control individual load segments (outlet.2.shutdown.return) on Powerware PW5125. > > Modified: > trunk/ChangeLog > trunk/drivers/bcmxcp.c > ... thanks, Arnaud -- Free Software Developer - http://arnaud.quette.free.fr/ Debian Developer - http://people.debian.org/~aquette/ Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/ Ubuntu Medi...
2013 Jun 28
2
How to Simulate UPS on battery?
...ssched/upssched.lock AT LOWBATT * START-TIMER lowbattwarn 1 AT ONBATT * START-TIMER onbattwarn 10 AT ONLINE * CANCEL-TIMER onbattwarn And here is the upsmon.conf on S2: $ cat /usr/local/etc/nut/upssched.conf RUN_AS_USER _ups MONITOR PW5125 at s1.EXAMPLE.COM 1 monuser tHEuNSPOKENpSWD slave MINSUPPLIES 1 SHUTDOWNCMD "/sbin/shutdown -r now" NOTIFYCMD /usr/local/sbin/upssched POLLFREQ 5 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME 15 POWERDOWNFLAG /etc/killpower NOTIFY...
2009 Jul 13
4
Accurate battery reports? (HP R3000 XR)
Hi I have a HP R3000 XR UPS which NUT never says is at 100% battery. It seems stuck in 98 or 99 . something percentage. How accurate should i expect the reports to be? All my other UPSes has been and is at 100%, even those i have retired. My monitor system runs debian. The host that is physically connected to this ups runs: nut 2.2.2-6.4 The web script runs nut-cgi 2.0.4-4 JonB