2005 Aug 23
2
SIP powercycle not hanging up
I have Sipura 841's talking to a CVS-HEAD of August 4.
If I disconnect the power to the Sipura, Asterisk does not hang up the
channel.
My sip.conf for this phone looks like:
;
[super1] ; Sipura 841
disallow = all
allow = ulaw
callerid = "super1"
2003 May 16
0
Info - Adit 600 console password reset
Just an FYI, I noticed some people not being able to use the CLI of their
adit 600's because of a set password. You can erase the configuration of
the adit 600 by setting the RST dip switch to on, powercycling the box,
waiting until it finishes coming up, setting it back to off, and
powercycling again.
-Joe
2004 Jan 31
1
Filesystem returned to state of six months ago after fsck
Recently our sysadm accidentally powercycled our server (RedHat8) after 198 days of uptime, and upon boot it insisted on checking one partition (/dev/sda7) in our RAID. When it was done, the files were in the state of August 23 last year, with anything newer either gone or invisible. I guess something went wrong with journaling data. What c...
2005 May 27
2
Grandstream GSX-2000 - dead :-(
...nd stay on, screen and buttons are dead. Connectivity to
Grandstream.com was always good - whenever I checked (I downloaded the
"User Manual" in a couple of minutes), the site states five minutes to
load, so waiting more than 30 mins should have been OK, and they do have
this "Please Powercycle" in red print too...
Is there a magic re-incarnation routine ?
(Power on whilst holding down some buttons?, Sprinkling chickens blood?)
I chose an HTTP upgrade over TFTP - as I read that there were potential
issues with TFTP at this firmware level.
--
. . ___. .__ Posix Syste...
2009 Jan 29
1
Fwd: upscode2.c
...upscsend("UPSD"); /* Set shutdown delay */
upscsend("1"); /* 1 second (lowest possible.
0 returns current.*/
upslogx(LOG_EMERG, "Shutting down...");
upscsend("UPPC"); /* Powercycle UPS */
upscsend("IJHLDMGCIU"); /* security code */
}
else {
upslogx(LOG_EMERG, "Shutdown called, but UPS does not
support it");
}
}
The problem is that the if(can_upsd && can_uppc) check was added
betwee...
2017 Jun 05
2
corrupted indexes rebuilding over and over
Hi,
On saturday one of our dovecot machines had an OOPS, and we had to
powercycle it. When it came up, it did a filesystem fsck (ext4) and
fixed a couple things, but nothing in lost+found.
Now, about 50 users have a problem where their indexes are
corrupted. Dovecot tries to fix them, but for some reason it is
failing. The users are seeing their mails duplicated and they canno...
2008 Mar 14
3
Anyone know of a pass through ATA
Anyone know of a company that makes a pass through ATA?
By pass through I mean have an Ethernet switch built into the ATA, like most
desktop phones have.
All of the dual ethernet ATA's I have seen have WAN/LAN ports, not two LAN
ports.
I fooled around with DMZ etc...but it just doesn't work as well.
Thermal
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
2017 Jun 05
0
corrupted indexes rebuilding over and over
...after a system failure. Our problem could be
solved by
rm /PATH/USER/mdbox/storage/dovecot.map.index*
doveadm -D -v force-resync -u USER INBOX
Best regards,
Gordon
On 05.06.2017 18:34, micah wrote:
>
> Hi,
>
> On saturday one of our dovecot machines had an OOPS, and we had to
> powercycle it. When it came up, it did a filesystem fsck (ext4) and
> fixed a couple things, but nothing in lost+found.
>
> Now, about 50 users have a problem where their indexes are
> corrupted. Dovecot tries to fix them, but for some reason it is
> failing. The users are seeing their mails...
2004 Sep 29
1
Budgetone problem
Hey guys,
I have a problem with my BudgeTone. It ignores calls after being online
with my asterisk server for an extended period of time. I know this
problem has been posted on this list before. Honestly, I searched the
archives but couldn't find the previous posts. Was there ever a solution to this problem ?
My firmware version is the latest: 1.0.5.11.
Once again, I apologize for posting
2004 Apr 19
1
"ext3-fs warning : ext3_block_to_path block <0 "
...em generates the following error messages on the console.
"ext3-fs warning : ext3_block_to_path block <0 "
This messages continues to be generated and occassionally causing the system to crash.
The problem is such that the system cannot be logged into even from the
console. Only a powercycle of the system works. Interestingly i have
another system with the same hardware and software configuration and
setup which works perfectly fine.
Though i am not sure it seems to be an issue with a specific file or
block on the mount device. However your suggestions or advice on how to go
about...
2004 Apr 19
0
Error "ext3-fs warning : ext3_block_to_path block <0 "
...e following error messages on the console.
"ext3-fs warning : ext3_block_to_path block <0 "
This messages continues to be generated, and is once in approx 2 months causing the system to crash.
The problem is such that the system cannot be logged into even from the
console. Only a powercycle of the system works. Interestingly i have
another system with the same hardware and software configuration and
setup which works perfectly fine.
Though i am not sure it seems to be an issue with a specific file or
block on the mount device. However your suggestions or advice on how to go
abo...
2006 Mar 01
0
Help with Digium TE210P, TDM400P card in Dell PE830
...h the
amber control LED flashing.
Sometimes (most frequent scenario) it just boots OK and when I connect
E1 plug in TE210P card it correctly clears red alarm status on the span
but do not reset channels and 'pri show span 1' shows that the span is down.
The only resolution is that I have to powercycle the box several times
with unplugged E1 until it starts working properly.
Not exactly what I would expect from a rock stable PBX.
Any help is appreciated.
Ondrej
Here is my zaptel.conf (although I doubt there is any config error)
# E1 Trunk ports
span=1,1,0,ccs,hdb3,crc4
span=2,0,0,ccs,hdb3,cr...
2003 Feb 25
0
Linux+samba problems
...pingable. If I use telnet
I do get a connection, but it doesn't continue to log me in. Even when connecting to port 22
(ssh) I get a connection, but the ssh server doesn't announce its version to me (as it does otherwise).
Also at the console I cannot so anything with the server, apart from powercycling it.
This happens about twice a day now, except for the weekends.
We analyzed the output from sar. All we could find was that 'totsck' (total sockets) is rising, and
reaching 900/1000 before the hang. ( approaching 1024 ??? ).
We tried running samba 2.2.7a, but this didn't help. Al...
2013 Jul 06
1
XenServer iSCSI / VDI Not Found
...ost that is having
issues.
Last night we attempted a snapshot on a VM that is critical to our
infrastructure. During the snapshot, the task locked up and was unable to
progress or stop the snapshot. I attempted to force the VM to stop as well
as destroy it''s domain. As a last resort I had powercycled the host.
Upon bringing the host online again the LUNs failed to mount properly on
both of the hosts in the same cluster, entering a "Broken" state where they
were listed as "unplugged" (two LUNs). This of course prevented the VMs
from starting and we received a "VDI Not...
2020 Sep 09
0
Re: Isolated bridge does not bridge
...br0 to br1 in the XML of both VM's with "virsh edit".
Just be certain that each guest is either completely inactive (doesn't
show up in the output of "virsh list" when you edit, or at some point
after you've edited it (i.e. there must be a complete "virtual
powercycle" of the guest for the changes to take effect).
> Then I did start the VM's using the serial console (no network):
> virsh start --console kvm66
> virsh start --console kvm68
>
> I cannot ping from one machine to the other. Why??
I guess you're using <interface ty...
2013 Jun 17
0
HP Blade Gen 7 and 8 IO stall with ciss driver
...DON'T see any normally
mentioned error messages on the console or in the remote logs.
Our main question: does anybody have similar experiences? Maybe on hp
supported os?
With best regards,
Philipp Maechler
Some more information:
I/O Stall:
The only solution to resolve the state is to "powercycle" the server.
Any network traffic or processing stuff also like entering kernel
debugger is possible, but shows only full I/O Queues...
reproducing:
scrubbing nonstop helps, but does result in a stall every week instead
of every 4 weeks... so nothing like 'next hour'.
Hardware:
G7: h...
2004 May 13
6
IAXy
Not sure if this is the best place but does any one have any used IAXy's
they are interested in selling?
I am looking to pick one up cheap for a proof of concept before going
all out on them.
Also does any one have any real life practical experience with how well
(or not so well) that these devices have worked for them?
you can reply to me off list at asterisk@matraex.com
Thanks
Michael
2019 Aug 23
2
Non Samba question
...le Transparency Effects
- remove/disable Cloud Sync.
- Disable "Fast startup", yes, you pc might start a bit faster,
but it will give you some nice problems back in the end, due to power saving/hibernation/Sleep states.
A reboot is not reboot anymore, it unloading/loading windows ( not powercycle) !
Disable it to be able to reboot your pc normaly.
Laptop/notebook might suffer from these problems and even worse, some have these settings enable in the bios
And windows will pick up these settings.
- Computer Configuration > Administrative Templates > Windows Components > Searc...
2007 Nov 28
1
Polycom MWI's will not turn off
Hello,
I have a bunch of Polycom 601's and Asterisk 1.4.13. The problem is that
the MWI indicators will never go off (The blinking red light and envelope in
the LCD).
I have tried to upgrade to 1.4.14 and all different SIP versions on the
Polycoms. I am now at 1.6.7
Here is the SIP Message that turns on the lights:
Scheduling destruction of SIP dialog '
2006 Jul 27
6
OT: remote power cycling
I'm in a situation where I'm going to have to deploy a rack of servers
in an unmanned location in another country. On rare occasions, I've had
systems that would not recover gracefully from a warm reboot and needed
the power cycled. Years ago, I had such a device from APC, but haven't
needed one in a long time since all my locations are staffed. I'd
welcome any