search for: pin9

Displaying 6 results from an estimated 6 matches for "pin9".

Did you mean: pin
2015 Nov 16
2
Contact-closure UPS
...e one UPS Infosec XP Pro 2500 RM and it works with windows sw RUPS2000. Now I want to install this UPS as virtual server on vmware ESXi vMA - (SUSE SLES 11SP2 linux). On this linux I have NUT 2.6.0 and I stopped now with configuration of genericups driver. Working cable (direct cable pin1-pin1 ... pin9-pin9) connection on Windows: PIN | PC | UPS __________________________________________________________________________________ Pin1 | DCD | described as DTR (must keep Hi) Pin2 | RxD | AC Power fail (NO, connected to pin4 UPS ground in case of AC failure) Pin3 | TxD | N/A...
2006 May 16
2
Meetme and authentication
...nique phone number (no matter if they are moderators or just plain users). I use Asterisk 1.2.6 The available conferences are defined as follows: conf => 1000,user pin1, moderator pin1 conf => 1001,user pin2, moderator pin2 conf => 1002,user pin3, moderator pin3 ... conf => 1009, user pin9, moderator pin9 The users are prompted whether they are a moderator or a user. When they choose, they are redirected to the conference they request: - using options aAPsX for moderators (moderator + marked + ask PIN + allow menu using *) - using options Psw for users (ask PIN + allow menu + wait f...
2015 Nov 16
0
Contact-closure UPS
...Pro 2500 RM and it works with windows sw RUPS2000. > Now I want to install this UPS as virtual server on vmware ESXi vMA - (SUSE SLES 11SP2 linux). > On this linux I have NUT 2.6.0 and I stopped now with configuration of genericups driver. > > Working cable (direct cable pin1-pin1 ... pin9-pin9) connection on Windows: > > PIN | PC | UPS > __________________________________________________________________________________ > Pin1 | DCD | described as DTR (must keep Hi) > Pin2 | RxD | AC Power fail (NO, connected to pin4 UPS ground in case of AC failur...
2015 Nov 16
2
Contact-closure UPS
...it works with windows sw RUPS2000. >> Now I want to install this UPS as virtual server on vmware ESXi vMA - (SUSE SLES 11SP2 linux). >> On this linux I have NUT 2.6.0 and I stopped now with configuration of genericups driver. >> >> Working cable (direct cable pin1-pin1 ... pin9-pin9) connection on Windows: >> >> PIN | PC | UPS >> __________________________________________________________________________________ >> Pin1 | DCD | described as DTR (must keep Hi) >> Pin2 | RxD | AC Power fail (NO, connected to pin4 UPS ground...
2015 Nov 21
2
Contact-closure UPS
>On Nov 20, 2015, at 12:17 PM, R?bert SZAKSZ <robert at szaksz.eu> wrote: >> >> No progress has been made: >> >> cable is UPS - PC >> 6 - 3 >> 7 - 5 >> 9 - 2 >> > >Maybe pins 4 and 7 (ground) both need to be connected on the UPS side? I connected both to pin 5 >Unfortunately, I don't think there is a safe way (in software)
2015 Nov 21
2
Contact-closure UPS
...t; May be the information (pls. see attachment) that UPS PIN1 should bee keept HI is mandatory. Should I connect it to PC PIN4 DTR? > >Certainly possible. blazer_ser and nutdrv_qx should set DTR high and RTS low by default, but that can be adjusted.> I will try to make both cables, but UPS PIN9 (TX) doesn't answer it seems like no power on it. >> >> OR >> >> I need to follow with contact closure cable? > >If the UPS is capable of the smart protocol, I still think that is worth trying first. But it's up to you. I am not 100% sure that smart protocol...