2015 Nov 16
2
Contact-closure UPS
...| RxD | AC Power fail (NO, connected to pin4 UPS ground in case of AC failure)
Pin3 | TxD | N/A
Pin4 | DTR | UPS ground
Pin5 | GND | Battery low (NO, connected to pin4 UPS ground in case of LB)
Pin6 | DSR | 1. described as UPS RxD and 2. 3 seconds Hi (UPS shutdown)
Pin7 | RTS | UPS ground
Pin8 | CTS | N/A
Pin9 | RI | described as UPS TxD
And the question is, how to configure CP[???], OL[???], LB[???], SD[???]?
No one from predefined 21 types worked for me.
Thank for help,
Robert SZAKSZ.
2005 May 16
1
2 servers via PRI
...cable be?
All I got on the web was to set one to "pri_net"...this cant be all?
And the cable
> pin1 <--> pin4> pin2 <--> pin5> pin3 <--> pin6> pin4 <--> pin1> pin5
<--> pin2> pin6 <--> pin3> pin5 <--> pin8> pin8 <--> pin7
Please Help and advice
Thanks Altus
2003 Jun 11
6
Testing two E400P with E1 cross-cable
...------+
The basic configuration seems ok, since zttool shows the links are OK.
I'm using this UTP cat5 cross-cable (not shielded):
pin1 <--> pin4
pin2 <--> pin5
pin3 <--> pin6
pin4 <--> pin1
pin5 <--> pin2
pin6 <--> pin3
pin5 <--> pin8
pin8 <--> pin7
I'm not really sure this is correct, since I've found only how to
connect pins 1,2,4 and 5. The other pins are connected as I supposed it
should be.
This is my zapata.conf:
Server#1 zapata.conf (Server#2 has the same zapata.conf but pri_net is
pri_cpe)
------------------------------...
2015 Nov 16
0
Contact-closure UPS
...ps can only send a BREAK signal (rather than receiving it).
> Pin3 | TxD | N/A
> Pin4 | DTR | UPS ground
> Pin5 | GND | Battery low (NO, connected to pin4 UPS ground in case of LB)
> Pin6 | DSR | 1. described as UPS RxD and 2. 3 seconds Hi (UPS shutdown)
> Pin7 | RTS | UPS ground
> Pin8 | CTS | N/A
> Pin9 | RI | described as UPS TxD
>
> And the question is, how to configure CP[???], OL[???], LB[???], SD[???]?
> No one from predefined 21 types worked for me.
>
The RUPS 2000 cable type in genericups seems to correspon...
2015 Nov 16
2
Contact-closure UPS
...nal (rather >than receiving it).
>
>> Pin3 | TxD | N/A
>> Pin4 | DTR | UPS ground
>> Pin5 | GND | Battery low (NO, connected to pin4 UPS ground in case of LB)
>> Pin6 | DSR | 1. described as UPS RxD and 2. 3 seconds Hi (UPS shutdown)
>> Pin7 | RTS | UPS ground
>> Pin8 | CTS | N/A
>> Pin9 | RI | described as UPS TxD
>>
>> And the question is, how to configure CP[???], OL[???], LB[???], SD[???]?
>> No one from predefined 21 types worked for me.
>>
>
>The RUPS 2000 cable type...