Displaying 8 results from an estimated 8 matches for "pin5".
Did you mean:
pin
2005 May 16
1
2 servers via PRI
...a connection between 2 asterisk servers via PRI
In Bri I would set one to NT and TE
How shoud the zapata.conf and zaptel.conf look
And how should the cable be?
All I got on the web was to set one to "pri_net"...this cant be all?
And the cable
> pin1 <--> pin4> pin2 <--> pin5> pin3 <--> pin6> pin4 <--> pin1> pin5
<--> pin2> pin6 <--> pin3> pin5 <--> pin8> pin8 <--> pin7
Please Help and advice
Thanks Altus
2006 Jan 20
1
Hardwiring a Tellabs echo canceller - help req
...incorrectly, so I thought I'd see if anyone can point me in the
right direction. Digium tech support pointed me to this doc for a standard
T1 cable:
http://www.arcelect.com/RJ48C_and_RJ48S_8_position_jack_.htm
which looks like it means:
pin1 = recieve ring
pin2 = recive tip
pin4 = send ring
pin5 = send tip
So I treated the bottom part of the diagram like a noraml cat5 cable &
connected it in this way:
Zap side | 2572 side
--------------------
pin 1 <=> pin 25
pin 2 <=> pin 21
pin 4 <=> pin 10
pin 5 <=> pin 6
on the T1 side I have:
T1 side | 2572 side
-----...
2003 Jun 11
6
Testing two E400P with E1 cross-cable
...|
| Span3 |--E1 crossover cable-->| Span3 |
| Span4 |--E1 crossover cable-->| Span4 |
+-------+ +-------+
The basic configuration seems ok, since zttool shows the links are OK.
I'm using this UTP cat5 cross-cable (not shielded):
pin1 <--> pin4
pin2 <--> pin5
pin3 <--> pin6
pin4 <--> pin1
pin5 <--> pin2
pin6 <--> pin3
pin5 <--> pin8
pin8 <--> pin7
I'm not really sure this is correct, since I've found only how to
connect pins 1,2,4 and 5. The other pins are connected as I supposed it
should be.
This is my...
2015 Nov 16
2
Contact-closure UPS
...PIN | PC | UPS
__________________________________________________________________________________
Pin1 | DCD | described as DTR (must keep Hi)
Pin2 | RxD | AC Power fail (NO, connected to pin4 UPS ground in case of AC failure)
Pin3 | TxD | N/A
Pin4 | DTR | UPS ground
Pin5 | GND | Battery low (NO, connected to pin4 UPS ground in case of LB)
Pin6 | DSR | 1. described as UPS RxD and 2. 3 seconds Hi (UPS shutdown)
Pin7 | RTS | UPS ground
Pin8 | CTS | N/A
Pin9 | RI | described as UPS TxD
And the question is, how to configure CP[???], OL...
2006 Jan 21
2
Tellabs 2572 EC Photos here.
...incorrectly, so I thought I'd see if anyone can
point me in the right direction. Digium tech support pointed me to this
doc for a standard
T1 cable:
http://www.arcelect.com/RJ48C_and_RJ48S_8_position_jack_.htm
which looks like it means:
pin1 = recieve ring
pin2 = recive tip
pin4 = send ring
pin5 = send tip
So I treated the bottom part of the diagram like a noraml cat5 cable &
connected it in this way:
Zap side | 2572 side
--------------------
pin 1 <=> pin 25
pin 2 <=> pin 21
pin 4 <=> pin 10
pin 5 <=> pin 6
on the T1 side I have:
T1 side | 2572 side
-----...
2015 Nov 16
0
Contact-closure UPS
...)
The genericups driver does not have a setting to use the PC RxD line as a contact-closure input. It seems to be possible if the other software is using it, but genericups can only send a BREAK signal (rather than receiving it).
> Pin3 | TxD | N/A
> Pin4 | DTR | UPS ground
> Pin5 | GND | Battery low (NO, connected to pin4 UPS ground in case of LB)
> Pin6 | DSR | 1. described as UPS RxD and 2. 3 seconds Hi (UPS shutdown)
> Pin7 | RTS | UPS ground
> Pin8 | CTS | N/A
> Pin9 | RI | described as UPS TxD
>
> And the question is...
2005 Jul 20
2
Computer doesn't shutdown, only broadcasts a message to say low battery
Hi,
I have a Liebert Powersure Personal XT 700 and have followed the
installation instructions from here
http://www.networkupstools.org/doc/2.0.0/INSTALL.html. I'm pretty sure
I've got the ups.conf, upsd.conf and ups.users correct. I have setup
upsmon.conf as suggested in the installtion guide with the exception of
FINALDELAY which I set to 0 when I found things weren't working
2015 Nov 16
2
Contact-closure UPS
...iver does not have a setting to use the PC RxD line as a contact-closure input. It seems to be possible if the other software is using it, but genericups can only send a BREAK signal (rather >than receiving it).
>
>> Pin3 | TxD | N/A
>> Pin4 | DTR | UPS ground
>> Pin5 | GND | Battery low (NO, connected to pin4 UPS ground in case of LB)
>> Pin6 | DSR | 1. described as UPS RxD and 2. 3 seconds Hi (UPS shutdown)
>> Pin7 | RTS | UPS ground
>> Pin8 | CTS | N/A
>> Pin9 | RI | described as UPS TxD
>>
>...