2005 May 16
1
2 servers via PRI
...a connection between 2 asterisk servers via PRI In Bri I would set one to NT and TE How shoud the zapata.conf and zaptel.conf look And how should the cable be? All I got on the web was to set one to "pri_net"...this cant be all? And the cable > pin1 <--> pin4> pin2 <--> pin5> pin3 <--> pin6> pin4 <--> pin1> pin5 <--> pin2> pin6 <--> pin3> pin5 <--> pin8> pin8 <--> pin7 Please Help and advice Thanks Altus
2006 Jan 20
1
Hardwiring a Tellabs echo canceller - help req
...incorrectly, so I thought I'd see if anyone can point me in the right direction. Digium tech support pointed me to this doc for a standard T1 cable: http://www.arcelect.com/RJ48C_and_RJ48S_8_position_jack_.htm which looks like it means: pin1 = recieve ring pin2 = recive tip pin4 = send ring pin5 = send tip So I treated the bottom part of the diagram like a noraml cat5 cable & connected it in this way: Zap side | 2572 side -------------------- pin 1 <=> pin 25 pin 2 <=> pin 21 pin 4 <=> pin 10 pin 5 <=> pin 6 on the T1 side I have: T1 side | 2572 side -----...
2003 Jun 11
6
Testing two E400P with E1 cross-cable
...| | Span3 |--E1 crossover cable-->| Span3 | | Span4 |--E1 crossover cable-->| Span4 | +-------+ +-------+ The basic configuration seems ok, since zttool shows the links are OK. I'm using this UTP cat5 cross-cable (not shielded): pin1 <--> pin4 pin2 <--> pin5 pin3 <--> pin6 pin4 <--> pin1 pin5 <--> pin2 pin6 <--> pin3 pin5 <--> pin8 pin8 <--> pin7 I'm not really sure this is correct, since I've found only how to connect pins 1,2,4 and 5. The other pins are connected as I supposed it should be. This is my...
2015 Nov 16
2
Contact-closure UPS
...PIN | PC | UPS __________________________________________________________________________________ Pin1 | DCD | described as DTR (must keep Hi) Pin2 | RxD | AC Power fail (NO, connected to pin4 UPS ground in case of AC failure) Pin3 | TxD | N/A Pin4 | DTR | UPS ground Pin5 | GND | Battery low (NO, connected to pin4 UPS ground in case of LB) Pin6 | DSR | 1. described as UPS RxD and 2. 3 seconds Hi (UPS shutdown) Pin7 | RTS | UPS ground Pin8 | CTS | N/A Pin9 | RI | described as UPS TxD And the question is, how to configure CP[???], OL...
2006 Jan 21
2
Tellabs 2572 EC Photos here.
...incorrectly, so I thought I'd see if anyone can point me in the right direction. Digium tech support pointed me to this doc for a standard T1 cable: http://www.arcelect.com/RJ48C_and_RJ48S_8_position_jack_.htm which looks like it means: pin1 = recieve ring pin2 = recive tip pin4 = send ring pin5 = send tip So I treated the bottom part of the diagram like a noraml cat5 cable & connected it in this way: Zap side | 2572 side -------------------- pin 1 <=> pin 25 pin 2 <=> pin 21 pin 4 <=> pin 10 pin 5 <=> pin 6 on the T1 side I have: T1 side | 2572 side -----...
2015 Nov 16
0
Contact-closure UPS
...) The genericups driver does not have a setting to use the PC RxD line as a contact-closure input. It seems to be possible if the other software is using it, but genericups can only send a BREAK signal (rather than receiving it). > Pin3 | TxD | N/A > Pin4 | DTR | UPS ground > Pin5 | GND | Battery low (NO, connected to pin4 UPS ground in case of LB) > Pin6 | DSR | 1. described as UPS RxD and 2. 3 seconds Hi (UPS shutdown) > Pin7 | RTS | UPS ground > Pin8 | CTS | N/A > Pin9 | RI | described as UPS TxD > > And the question is...
2005 Jul 20
2
Computer doesn't shutdown, only broadcasts a message to say low battery
Hi, I have a Liebert Powersure Personal XT 700 and have followed the installation instructions from here http://www.networkupstools.org/doc/2.0.0/INSTALL.html. I'm pretty sure I've got the ups.conf, upsd.conf and ups.users correct. I have setup upsmon.conf as suggested in the installtion guide with the exception of FINALDELAY which I set to 0 when I found things weren't working
2015 Nov 16
2
Contact-closure UPS
...iver does not have a setting to use the PC RxD line as a contact-closure input. It seems to be possible if the other software is using it, but genericups can only send a BREAK signal (rather >than receiving it). > >> Pin3 | TxD | N/A >> Pin4 | DTR | UPS ground >> Pin5 | GND | Battery low (NO, connected to pin4 UPS ground in case of LB) >> Pin6 | DSR | 1. described as UPS RxD and 2. 3 seconds Hi (UPS shutdown) >> Pin7 | RTS | UPS ground >> Pin8 | CTS | N/A >> Pin9 | RI | described as UPS TxD >> >...