Displaying 6 results from an estimated 6 matches for "pin3".
Did you mean:
pin
2005 May 16
1
2 servers via PRI
...ion between 2 asterisk servers via PRI
In Bri I would set one to NT and TE
How shoud the zapata.conf and zaptel.conf look
And how should the cable be?
All I got on the web was to set one to "pri_net"...this cant be all?
And the cable
> pin1 <--> pin4> pin2 <--> pin5> pin3 <--> pin6> pin4 <--> pin1> pin5
<--> pin2> pin6 <--> pin3> pin5 <--> pin8> pin8 <--> pin7
Please Help and advice
Thanks Altus
2006 May 16
2
Meetme and authentication
...conference line that users would call using
a unique phone number (no matter if they are moderators or just plain
users). I use Asterisk 1.2.6
The available conferences are defined as follows:
conf => 1000,user pin1, moderator pin1
conf => 1001,user pin2, moderator pin2
conf => 1002,user pin3, moderator pin3
...
conf => 1009, user pin9, moderator pin9
The users are prompted whether they are a moderator or a user. When they
choose, they are redirected to the conference they request:
- using options aAPsX for moderators (moderator + marked + ask PIN +
allow menu using *)
- using optio...
2003 Jun 11
6
Testing two E400P with E1 cross-cable
...pan3 |--E1 crossover cable-->| Span3 |
| Span4 |--E1 crossover cable-->| Span4 |
+-------+ +-------+
The basic configuration seems ok, since zttool shows the links are OK.
I'm using this UTP cat5 cross-cable (not shielded):
pin1 <--> pin4
pin2 <--> pin5
pin3 <--> pin6
pin4 <--> pin1
pin5 <--> pin2
pin6 <--> pin3
pin5 <--> pin8
pin8 <--> pin7
I'm not really sure this is correct, since I've found only how to
connect pins 1,2,4 and 5. The other pins are connected as I supposed it
should be.
This is my zapat...
2015 Nov 16
2
Contact-closure UPS
...ble pin1-pin1 ... pin9-pin9) connection on Windows:
PIN | PC | UPS
__________________________________________________________________________________
Pin1 | DCD | described as DTR (must keep Hi)
Pin2 | RxD | AC Power fail (NO, connected to pin4 UPS ground in case of AC failure)
Pin3 | TxD | N/A
Pin4 | DTR | UPS ground
Pin5 | GND | Battery low (NO, connected to pin4 UPS ground in case of LB)
Pin6 | DSR | 1. described as UPS RxD and 2. 3 seconds Hi (UPS shutdown)
Pin7 | RTS | UPS ground
Pin8 | CTS | N/A
Pin9 | RI | described as UPS T...
2015 Nov 16
0
Contact-closure UPS
...er fail (NO, connected to pin4 UPS ground in case of AC failure)
The genericups driver does not have a setting to use the PC RxD line as a contact-closure input. It seems to be possible if the other software is using it, but genericups can only send a BREAK signal (rather than receiving it).
> Pin3 | TxD | N/A
> Pin4 | DTR | UPS ground
> Pin5 | GND | Battery low (NO, connected to pin4 UPS ground in case of LB)
> Pin6 | DSR | 1. described as UPS RxD and 2. 3 seconds Hi (UPS shutdown)
> Pin7 | RTS | UPS ground
> Pin8 | CTS | N/A
> Pin9 |...
2015 Nov 16
2
Contact-closure UPS
...ed to pin4 UPS ground in case of AC failure)
>
>The genericups driver does not have a setting to use the PC RxD line as a contact-closure input. It seems to be possible if the other software is using it, but genericups can only send a BREAK signal (rather >than receiving it).
>
>> Pin3 | TxD | N/A
>> Pin4 | DTR | UPS ground
>> Pin5 | GND | Battery low (NO, connected to pin4 UPS ground in case of LB)
>> Pin6 | DSR | 1. described as UPS RxD and 2. 3 seconds Hi (UPS shutdown)
>> Pin7 | RTS | UPS ground
>> Pin8 | CTS...