Displaying 5 results from an estimated 5 matches for "p00500x".
2014 Jun 29
1
The dreaded Tripp Lite SMART500RT1U and NUT
...00 00 64 00 0d 'S....d..' (OK)
   9.476533    send_to_all: SETINFO ups.mfr "Tripp Lite"
   9.476718    send_cmd(msg_len=2, type='P')
   9.477542    send_cmd: sending  3a 50 af 0d 00 00 00 00 '.P......'
   9.579226    send_cmd: received 50 30 30 35 30 30 58 0d 'P00500X.' (OK)
   9.579630    send_to_all: SETINFO ups.model "SMART500RT1U"
   9.580498    send_to_all: SETINFO ups.power.nominal "500"
   9.580690    send_cmd(msg_len=2, type='F')
   9.580881    send_cmd: sending  3a 46 b9 0d 00 00 00 00 '.F......'
   9.682969    se...
2014 Jun 28
0
The dreaded Tripp Lite SMART500RT1U and NUT
On Thu, Jun 26, 2014 at 10:20 PM, Steve Ballantyne
<steve.ballantyne at gmail.com> wrote:
>> However, we don't have all of the 09AE/0001 protocols decoded in the
>> tripplite_usb driver.
>
> I can try to help out on this front?  :-)
Definitely.
>> >    9.783126     Unknown input voltage range: 0x02
>> >    9.783308     Unknown number of switchable
2014 Jun 27
3
The dreaded Tripp Lite SMART500RT1U and NUT
...>    9.472712     send_to_all: SETINFO ups.mfr "Tripp Lite"
> >    9.472899     send_cmd(msg_len=2, type='P')
> >    9.473087     send_cmd: sending  3a 50 af 0d 00 00 00 00 '.P......'
> >    9.575667     send_cmd: received 50 30 30 35 30 30 58 0d 'P00500X.' (OK)
> >    9.576026     send_to_all: SETINFO ups.model "SMART500RT1U"
> >    9.576848     send_to_all: SETINFO ups.power.nominal "500"
>
> 500W sounds right based on the name.
Yes!  It is a 500W, for sure.
> >    9.577346     send_cmd(msg_len=2,...
2014 Jun 26
1
The dreaded Tripp Lite SMART500RT1U and NUT
...00 64 00 0d 'S....d..' (OK)
   9.472712     send_to_all: SETINFO ups.mfr "Tripp Lite"
   9.472899     send_cmd(msg_len=2, type='P')
   9.473087     send_cmd: sending  3a 50 af 0d 00 00 00 00 '.P......'
   9.575667     send_cmd: received 50 30 30 35 30 30 58 0d 'P00500X.' (OK)
   9.576026     send_to_all: SETINFO ups.model "SMART500RT1U"
   9.576848     send_to_all: SETINFO ups.power.nominal "500"
   9.577346     send_cmd(msg_len=2, type='F')
   9.578194     send_cmd: sending  3a 46 b9 0d 00 00 00 00 '.F......'
   9.679786...
2015 Jan 06
2
libusb drops connection to my Tripp Lite SMART500T1U
...?  Is there something
I can do to tell the libusb to wait a little longer for the device to
come back?
3116.403776     send_cmd(msg_len=2, type='P')
3116.403858     send_cmd: sending  3a 50 af 0d 00 00 00 00 '.P......'
3116.506490     send_cmd: received 50 30 30 35 30 30 58 0d 'P00500X.' (OK)
3117.449881     send_cmd(msg_len=2, type='S')
3117.451603     send_cmd: sending  3a 53 ac 0d 00 00 00 00 '.S......'
3118.555755     libusb_get_interrupt: Connection timed out
3118.557454     libusb_get_interrupt() returned 0 instead of 8 while
sending 3a 53 ac 0d 00 00 00...