search for: overcurrent

Displaying 15 results from an estimated 15 matches for "overcurrent".

2008 Dec 01
1
Unitek Self Protek Mistral 1000ipF
...None Usage Type Data wMaxPacketSize 0x0002 1x 2 bytes bInterval 255 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 2 wHubCharacteristic 0x000a No power switching (usb 1.0) Per-port overcurrent protection bPwrOn2PwrGood 1 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Device Status: 0x0003 Self Powered Remote Wakeup Enabled Bus 002 Device...
2013 Jan 13
0
Evolution 850 not recognized by NUT 2.6.5?
...? ? ? None ? ? ? ? ? Usage Type ? ? ? ? ? ? ? Data ? ? ? ? wMaxPacketSize ? ? 0x0004 ?1x 4 bytes ? ? ? ? bInterval ? ? ? ? ? ? ?12 Hub Descriptor: ? bLength ? ? ? ? ? ? ? 9 ? bDescriptorType ? ? ?41 ? nNbrPorts ? ? ? ? ? ? 5 ? wHubCharacteristic 0x000a ? ? No power switching (usb 1.0) ? ? Per-port overcurrent protection ? bPwrOn2PwrGood ? ? ? 10 * 2 milli seconds ? bHubContrCurrent ? ? ?0 milli Ampere ? DeviceRemovable ? ?0x00 ? PortPwrCtrlMask ? ?0xff ?Hub Port Status: ? ?Port 1: 0000.0100 power ? ?Port 2: 0000.0100 power ? ?Port 3: 0000.0100 power ? ?Port 4: 0000.0100 power ? ?Port 5: 0000.0100 power...
2007 Aug 19
4
OMRON BX35F
Hi nut-upsdev, I have just got OMRON BX35F. Only object files and usage information is included. Where should I start to help you to get it supported? Any interest in supporting it at all?
2014 Sep 06
0
NUT Quit Working [Tripp Lite; USB 3.0]
On Sep 6, 2014, at 4:16 PM, Leslie Rhorer <lrhorer at mygrande.net> wrote: > Oh, hey! That seems to have worked. I'm sure the UPS got plugged into a different port one of the (many) times the server was removed from the relay rack, and it was on a USB 3.0 port. I moved it to a 1.0 port and everything seems to be working just fine. The specifics of the motherboard and its USB
2006 Oct 11
2
Adding TrippLite SMART550 / Protocol 2001 Support
...e '1': + dstate_setinfo("battery.test.status", "Battery bad - replace"); + break; + case '2': + status_set("CAL"); + break; + case '3': + status_set("OVER"); + dstate_setinfo("battery.test.status", "Overcurrent?"); + break; + case '4': + /* The following message is confusing, and may not be accurate: */ + /* dstate_setinfo("battery.test.status", "Battery state unknown"); */ + break; + case '5': + status_set("OVER"); + dstate_setinfo(...
2007 May 05
1
powermust usb
...None Usage Type Data wMaxPacketSize 0x0002 1x 2 bytes bInterval 12 Hub Descriptor: bLength 11 bDescriptorType 41 nNbrPorts 8 wHubCharacteristic 0x000a No power switching (usb 1.0) Per-port overcurrent protection TT think time 8 FS bits bPwrOn2PwrGood 10 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0xb7 0xc8 PortPwrCtrlMask 0xa0 0x08 Hub Port Status: Port 1: 0000.0000 Port 2: 0000.0100 power Port 3: 0000.0100 power Port 4: 0000.0100...
2014 Sep 06
2
NUT Quit Working
On 9/6/2014 12:47 PM, Charles Lepple wrote: > On Sep 6, 2014, at 12:39 PM, Leslie Rhorer <lrhorer at mygrande.net> wrote: > >> I made a number of hardware and software changes, including an upgrade to the latest software versions for that distro (Debian Wheezy), > > Can you be more specific about the changes? Well, I did an automated upgrade (apt-get upgrade), I changed
2008 Jan 07
1
INFOSEC 500 XP usb support
...e None Usage Type Data wMaxPacketSize 0x0004 1x 4 bytes bInterval 12 Hub Descriptor: bLength 11 bDescriptorType 41 nNbrPorts 8 wHubCharacteristic 0x000a No power switching (usb 1.0) Per-port overcurrent protection TT think time 8 FS bits bPwrOn2PwrGood 10 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 0x60 PortPwrCtrlMask 0x17 0x15 Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Port 3: 0000.0100 power Port 4: 0000.0100 powe...
2006 Jul 24
1
Fw: INFOSEC 500 XP en USB et drivers newhidups avec '-x generic'
...Usage Type Data wMaxPacketSize 0x0002 1x 2 bytes bInterval 255 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 2 wHubCharacteristic 0x000a No power switching (usb 1.0) Per-port overcurrent protection bPwrOn2PwrGood 1 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0x00 Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0303 lowspeed power enable connect Device Status: 0x0001 Self Power...
2010 Sep 16
1
Soyntec Sekury A600 VA
...None Usage Type Data wMaxPacketSize 0x0004 1x 4 bytes bInterval 12 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 3 wHubCharacteristic 0x0009 Per-port power switching Per-port overcurrent protection TT think time 8 FS bits bPwrOn2PwrGood 10 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0108 power oc Port 2: 0000.030b lowspeed power oc enable connect Port 3: 0000.0108 po...
2006 Oct 13
5
Polycom IP 501 phone randomly resets itself (loses Received call log, Missed calls, placed calls)
I've been noticing that my group of Polycom IP 501 phones seems to randomly reset themselves nearly every night (I guess it usually happens at night, since I've never seen it happen while I've been at work during the day).. When I say "reset", I mean, the hands free volume and ring volume are set to the default and the call logs (received calls, missed calls, placed calls)
2008 Feb 01
2
Four UPS's via usb.
> Hello everyone. I try to connect four PowerMust 2000 ups's via usb to one > computer using megatec_usb driver. But megatec_usb completly ignores port > directive in ups.conf, I even try port = /dev/null and megatec_usb founds > ups and it works. The 'port' is not used for USB connected devices, it's only needed for compatibility reasons. > Problem is that
2011 Jul 01
16
Power-outage
I have a CentOS-5.6 remote server in a house in Italy, where there are occasional thunder-storms. There was one yesterday, when the electricity went off 3 times, for a second or so on each occasion. My server, an HP MicroServer, came back (re-booted) on 2 of the 3 occasions, but not on the third. I assume that the problem arises because the machine does not close down properly. (Although it is
2007 Jun 16
1
4 GB USB flash disk with FAT ok, with ext3 corrupted files
...None Usage Type Data wMaxPacketSize 0x0002 1x 2 bytes bInterval 255 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 2 wHubCharacteristic 0x000a No power switching (usb 1.0) Per-port overcurrent protection bPwrOn2PwrGood 1 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0300 lowspeed power Port 2: 0000.0300 lowspeed power Device Status: 0x0003 Self Powered Remote Wakeup Enable...
2010 Jan 13
28
New ZFS Intent Log (ZIL) device available - Beta program now open!
The DDRdrive X1 OpenSolaris device driver is now complete, please join us in our first-ever ZFS Intent Log (ZIL) beta test program. A select number of X1s are available for loan, preferred candidates would have a validation background and/or a true passion for torturing new hardware/driver :-) We are singularly focused on the ZIL device market, so a test environment bound by synchronous writes