2016 Sep 29
2
[PATCH] drm/therm/fan: add a fallback if no fan control is specified in the vbios
This seems to be absolutely necessary for a lot of NV40.
Reported-by: gsgf on IRC/freenode
Signed-off-by: Martin Peres <martin.peres at free.fr>
---
drm/nouveau/nvkm/subdev/therm/base.c | 22 +++++++++++++++++++---
1 file changed, 19 insertions(+), 3 deletions(-)
diff --git a/drm/nouveau/nvkm/subdev/therm/base.c b/drm/nouveau/nvkm/subdev/therm/base.c
index 8894fee..df949fa 100644
---
2016 Oct 03
0
[PATCH] drm/therm/fan: add a fallback if no fan control is specified in the vbios
On 29/09/16 03:41, Martin Peres wrote:
> This seems to be absolutely necessary for a lot of NV40.
>
> Reported-by: gsgf on IRC/freenode
> Signed-off-by: Martin Peres <martin.peres at free.fr>
I of course forgot to tag this patch for stable. The thing has been
broken on some nv40 ... forever?
> ---
> drm/nouveau/nvkm/subdev/therm/base.c | 22 +++++++++++++++++++---
>
2017 Jul 21
15
[RFC PATCH 00/13] Thermal throttling
Adds Nouveau controlled thermal throttling for Kepler+ GPUs. With this I feel
safe enough to add support for Maxwell2 reclocking later on (still hidden
behind a switch, but we can be fairly sure to not overheat hardware if a user
isn't carefull enough)
Contains all patches from my clk update series, but I thought it makes sense
to include those in this series as well for completness.
Please
2020 Sep 16
2
[PATCH v2 1/2] drm/nouveau: return temperatures in temp_get() via parameter
The temp_get() function currently returns negative error numbers or a
temperature. However, the thermal sensors can (in theory) measure
negative temperatures. Some implementations of temp_get() correctly
clamp negative temperature readings to 0 so that users do not mistake
them for errors, but some, like gp100_temp_get(), do not.
Rather than relying on implementations remembering to clamp values,
2020 Sep 16
2
[PATCH v2 1/2] drm/nouveau: return temperatures in temp_get() via parameter
On Wed, Sep 16, 2020 at 10:01 PM Karol Herbst <kherbst at redhat.com> wrote:
>
> On Wed, Sep 16, 2020 at 9:47 PM Jeremy Cline <jcline at redhat.com> wrote:
> >
> > The temp_get() function currently returns negative error numbers or a
> > temperature. However, the thermal sensors can (in theory) measure
> > negative temperatures. Some implementations of
2017 Nov 22
2
[PATCH 03/32] therm: Split return code and value in nvkm_get_temp
On 17/11/17 02:04, Karol Herbst wrote:
> The current hwmon code doesn't check if the returned value was actually an
> error.
>
> Since Kepler temperature sensors are able to report negative values. Those
> negative values are not for error reporting, but rather when you buried
> your GPU in snow somewhere in Antarctica and still want a valid
> temperature to be reported
2017 Nov 17
35
[PATCH 00/32] Updated State of my clk patches
Last update here: https://lists.freedesktop.org/archives/nouveau/2017-September/028848.html
Basically big cleanup, reordering, simplifications and some renaming to make
the code easier to read and to review. I also moved some bugfixes to the front
so they can be merged prior the other patches.
There was also a bug related to the therm daemon triggering a pstate change
leading to PMU lockups,
2017 Oct 08
1
[RFC PATCH 01/29] therm: split return code and value in nvkm_get_temp
As you changed the return value of `temp_get()` to solely be the error code, or
absence of an error, I would change all those tests that checked whether the
returned value was strictly less, or greater than, 0 to now only compare
against 0 (no error). For example,
if (therm && therm->attr_get && nvkm_therm_temp_get(therm, &val) < 0)
if
2017 Sep 15
0
[RFC PATCH 01/29] therm: split return code and value in nvkm_get_temp
The current hwmon code doesn't check if the returned value was actually an
error.
Since Kepler temperature sensors are able to report negative values.
Since Pascal (and maybe earlier) we have sensors with improved precision.
Adjust the nvkm_get_temp method to be able to deal with those changes
and let hwmon return an error properly.
Signed-off-by: Karol Herbst <karolherbst at
2017 Nov 22
1
[PATCH 03/32] therm: Split return code and value in nvkm_get_temp
On 22/11/17 03:42, Karol Herbst wrote:
> On Wed, Nov 22, 2017 at 1:32 AM, Martin Peres <martin.peres at free.fr> wrote:
>> On 17/11/17 02:04, Karol Herbst wrote:
>>> The current hwmon code doesn't check if the returned value was actually an
>>> error.
>>>
>>> Since Kepler temperature sensors are able to report negative values. Those
2020 Sep 16
0
[PATCH v2 1/2] drm/nouveau: return temperatures in temp_get() via parameter
On Wed, Sep 16, 2020 at 9:47 PM Jeremy Cline <jcline at redhat.com> wrote:
>
> The temp_get() function currently returns negative error numbers or a
> temperature. However, the thermal sensors can (in theory) measure
> negative temperatures. Some implementations of temp_get() correctly
> clamp negative temperature readings to 0 so that users do not mistake
> them for
2017 Sep 15
42
[RFC PATCH 00/29] Current State of my clk patches
Just wanted to post updated versions of my last series/patches. Reviews
welcomed.
It would be also nice if we agree on features I should focus upstreaming, so
that this work can be better splitted or reordered.
Sadly most of my patches depend on the rather big clk subdev rework and I think
those patches shows best, why I think this rework is actually needed and makes
things much easier to add
2017 Nov 17
0
[PATCH 03/32] therm: Split return code and value in nvkm_get_temp
The current hwmon code doesn't check if the returned value was actually an
error.
Since Kepler temperature sensors are able to report negative values. Those
negative values are not for error reporting, but rather when you buried
your GPU in snow somewhere in Antarctica and still want a valid
temperature to be reported (unverified).
Since Pascal (and maybe earlier) we have sensors with
2020 Sep 17
0
[PATCH v2 1/2] drm/nouveau: return temperatures in temp_get() via parameter
On Wed, Sep 16, 2020 at 10:03:22PM +0200, Karol Herbst wrote:
> On Wed, Sep 16, 2020 at 10:01 PM Karol Herbst <kherbst at redhat.com> wrote:
> >
> > On Wed, Sep 16, 2020 at 9:47 PM Jeremy Cline <jcline at redhat.com> wrote:
> > >
> > > The temp_get() function currently returns negative error numbers or a
> > > temperature. However, the thermal
2017 Nov 22
0
[PATCH 03/32] therm: Split return code and value in nvkm_get_temp
On Wed, Nov 22, 2017 at 1:32 AM, Martin Peres <martin.peres at free.fr> wrote:
> On 17/11/17 02:04, Karol Herbst wrote:
>> The current hwmon code doesn't check if the returned value was actually an
>> error.
>>
>> Since Kepler temperature sensors are able to report negative values. Those
>> negative values are not for error reporting, but rather when you
2017 Sep 02
3
[PATCH 0/3] Several hwmon fixes
We should simply return errors while the GPU is turned off, because the sensors
aren't accessable and setting any kind of value doesn't make any sense. Fixes
sensors values reported by "sensors"
Before:
nouveau-pci-0100
Adapter: PCI adapter
GPU core: +0.60 V (min = +0.60 V, max = +1.20 V)
temp1: -0.0°C (high = +95.0°C, hyst = +3.0°C)
(crit
2020 Aug 12
6
[PATCH] drm/nouveau: Add fine-grain temperature reporting
Commit d32656373857 ("drm/nouveau/therm/gp100: initial implementation of
new gp1xx temperature sensor") added support for reading finer-grain
temperatures, but continued to report temperatures in 1 degree Celsius
increments via nvkm_therm_temp_get().
Rather than altering nvkm_therm_temp_get() to report finer-grain
temperatures, which would be inconvenient for other users of the