Displaying 8 results from an estimated 8 matches for "myups1".
Did you mean:
myups
2016 Jul 14
2
Windows Version not working --
...I and it installed
fine, although I nee to also get a libusb0.dll.
Connected USB to a Triplite, I could go to the Devices and Printers and
see the USB installed.
But no matter what I did I could not get nut to work. I tried various
commands, and got various errors.
my config has --
[myups1]
driver = usbhid-ups
port = auto
vendorid = 09ae
# cable = 1234
desc = "Something descriptive"
was trying bin\upsc myups1 and I tried bin\upsc myups1 at localhost:3493
Never could get it give me a snap shot of the UPS, just unknown
communication error --
Also tried,...
2019 Mar 30
2
upssched Not Running
2019 Apr 03
2
upssched Not Running
...o uncomment all of the NOTIFYFLAG statements whether I was
> changing them or not. Previously, I had a mixture of commented and
> uncommented, assuming the commented ones used default values.
>
> $ grep -Ev "^(#|\s*$)" /etc/nut/upsmon.conf
> RUN_AS_USER nut
> MONITOR myups1 at localhost:3493 1 nutmaster pass master
> MINSUPPLIES 1
> SHUTDOWNCMD "/sbin/shutdown --poweroff +1"
> NOTIFYCMD /sbin/upssched
> POLLFREQ 10
> POLLFREQALERT 5
> HOSTSYNC 15
> DEADTIME 15
> POWERDOWNFLAG /etc/nut/killpower
> NOTIFYFLAG ONLINE SYSLOG+WALL+EXE...
2019 Apr 03
0
upssched Not Running
2019 May 25
2
Low Battery False Alarms
2019 May 26
2
Low Battery False Alarms
2020 Jun 18
3
Low Battery Problems
...e a CyberPower 1500VA running on Debian (testing) Linux connected via USB. This was also the same model I had before, so I've used this for a long time with no problems until recently.
I have tried to play with the low battery settings in ups.conf to no avail. Here is my ups.conf as of now:
[myups1]
driver = usbhid-ups
port = auto
vendorid = 0764
desc = "CyberPower 1500VA"
pollinterval = 10
ignorelb
override.battery.charge.low = 60
override.battery.charge.warning = 80
override.battery.runtime.low = 600
Here is some information regarding...
2019 May 25
2
Low Battery False Alarms