Displaying 19 results from an estimated 19 matches for "linevoltage".
2006 Dec 11
2
howto setup BNT-1500AP on gentoo
...d command emerge nut. All has passed successfully. I use
UPS POWERCOM BNT-1500AP. It is connected to serial port 1, i.e. for my
system it/dev/tts/0. In/etc/nut/ups.conf
[powercom]
driver = powercom
port = /dev/tts/0
desc = "PowerCom BNT-1500AP on IP-PBX"
modelname = "BNT-1500AP"
linevoltage = 230
type = KIN1500AP
also trying:
[powercom]
driver = powercom
port = /dev/tts/0
desc = "PowerCom BNT-1500AP on IP-PBX"
modelname = "BNT-1500AP"
linevoltage = 230
type = Egys
At start by a command/etc/init.d/upsdrv start gives out the following:
* Starting UPS drivers .....
2009 Dec 27
4
XPCC XVRT-1000 driver
-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1
Has anyone used nut with a XPCC UPS, in particular one of the XVRT
units? Their supplied monitoring tool "works", but I'd really prefer to
use nut if possible. I've systematically gone through each of the
drivers in /lib/nut and none seem to talk with the unit properly.
I'll be talking with a XPCC support person tomorrow, though
2006 Aug 18
0
(no subject)
...e: (null)
input.voltage: -0.1
output.voltage: 57.6
STATUS: OB
upsc with UPS connected to the mains:
Network UPS Tools upsd 2.0.4
Connected to UPS [Inform]: powercom-ttyS0
Synchronizing...done
root@marto:/home/marto# upsc Inform@localhost
battery.charge: 108.8
driver.name: powercom
driver.parameter.linevoltage: 220
driver.parameter.port: /dev/ttyS0
driver.parameter.shutdownArguments: {{1,0},y}
driver.parameter.type: Egys
driver.version: 2.0.4
driver.version.internal: $ Revision: 0.5 $
input.frequency: 49.10
input.voltage: 234.3
input.voltage.nominal: 220
output.frequency: 49.10
output.voltage: 234.3
ups....
2006 Aug 17
1
powercom upstype identify problem
...o run as user root, because otherwise the command "telinit 0" from the notifyme script does not have the permission to execute. Currently the output of "upsc Inform@localhost" when the UPS is connected to the mains is:
battery.charge: 97.7
driver.name: powercom
driver.parameter.linevoltage: 220
driver.parameter.port: /dev/ttyS0
driver.parameter.type: KIN1500AP
driver.version: 2.0.4
driver.version.internal: $ Revision: 0.5 $
input.frequency: 49.61
input.voltage: 236.3
input.voltage.nominal: 220
output.frequency: 49.61
output.voltage: 236.3
ups.load: 36.7
ups.mfr: PowerCom
ups.model: U...
2024 Mar 21
0
There is no voltage information
...t;>>
>>>>> Network UPS Tools - UPS driver controller 2.8.0
>>>>> Network UPS Tools - Generic HID driver 0.47 (2.8.0)
>>>>> USB communication driver (libusb 1.0) 0.43
>>>>> Using subdriver: Belkin/Liebert HID 0.18
>>>>> LineVoltage exponent looks wrong, but not correcting.
>>>>> LineVoltage exponent looks wrong, but not correcting.
>>>>> LineVoltage exponent looks wrong, but not correcting.
>>>>> ConfigVoltage exponent looks wrong, but not correcting.
>>>>>
>>&...
2007 Dec 29
1
Odd Values For Powercoms
...UPS supports logging of the "boost" or
"buck" lights?
BATTERY:
ads-bsh-fwd4# upsc ups1
battery.charge: 158.9 <-- Wierd
driver.name: powercom
driver.parameter.batteryPercentage: {5.0000,0.3268,-825.00,0.46511,0}
driver.parameter.frequency: {0.00020997,0.0}
driver.parameter.linevoltage: 110
driver.parameter.loadPercentage: {6.1343,-0.3808,1.075,0.1811}
driver.parameter.manufacturer: PowerCom
driver.parameter.methodOfFlowControl: dtr0rts1
driver.parameter.numOfBytesFromUPS: 16
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/cuaa0
driver.parameter.shutdownArguments: {{...
2006 Aug 17
0
(no subject)
So, this is the result of upsc Inform@localhost with the UPS connected to the mains:
battery.charge: 97.7
driver.name: powercom
driver.parameter.linevoltage: 220
driver.parameter.port: /dev/ttyS0
driver.parameter.type: KIN1500AP
driver.version: 2.0.4
driver.version.internal: $ Revision: 0.5 $
input.frequency: 49.61
input.voltage: 236.3
input.voltage.nominal: 220
output.frequency: 49.10
output.voltage: 236.3
ups.load: 38.9
ups.mfr: PowerCom
ups.model: U...
2011 May 17
3
Powercom issues in NUT (was: PowerCom BNT2000AT ups on nut 2.6.0 - second try)
Dino, Alexey,
there are a number of users suffering issues with your Powercom devices.
Could you (Dino, and Keven if possible) please have a look at the below one,
from Angela, and check for a fix?
I've scheduled to release 2.6.1 next week, and having that fixed is part of
the list.
2011/5/16 Angela Williams <angierfw at gmail.com>
> Hi All
>
> On Friday 13 May 2011 at
2007 Dec 24
3
Driver for Powercom BNT/KIN/IMP/IMD series
...pport ( BNT-400/500/600/800/801/1000/1200/1500/2000AP
220-240V )
- add Powercom's King Pro model support (
KIN-425/525/625/800/1000/1200/1500/1600/2200/3000/5000AP[-RM] 100-120,200-240 V)
- add Powercom's Imperial model support ( IMP-xxxAP, IMD-xxxAP )
Only for BNT/KIN/IMP/IMD:
power and linevoltage whould detect automatically now
also you don't need any other coefficients in ups.conf
added shutdown.stayoff and shutdown.return commands
start battery.test on driver start
Tested on: BNT-1200AP
Known bugs:
- strange battery level on BNT1200AP ( & may be on other models)
- can't...
2024 Mar 25
0
There is no voltage information
...Network UPS Tools - UPS driver controller 2.8.0
>>>>>>> Network UPS Tools - Generic HID driver 0.47 (2.8.0)
>>>>>>> USB communication driver (libusb 1.0) 0.43
>>>>>>> Using subdriver: Belkin/Liebert HID 0.18
>>>>>>> LineVoltage exponent looks wrong, but not correcting.
>>>>>>> LineVoltage exponent looks wrong, but not correcting.
>>>>>>> LineVoltage exponent looks wrong, but not correcting.
>>>>>>> ConfigVoltage exponent looks wrong, but not correcting.
>&g...
2024 Mar 25
0
There is no voltage information
...Network UPS Tools - UPS driver controller 2.8.0
>>>>>>> Network UPS Tools - Generic HID driver 0.47 (2.8.0)
>>>>>>> USB communication driver (libusb 1.0) 0.43
>>>>>>> Using subdriver: Belkin/Liebert HID 0.18
>>>>>>> LineVoltage exponent looks wrong, but not correcting.
>>>>>>> LineVoltage exponent looks wrong, but not correcting.
>>>>>>> LineVoltage exponent looks wrong, but not correcting.
>>>>>>> ConfigVoltage exponent looks wrong, but not correcting.
>&g...
2006 Aug 16
5
Master privileges unavailable on UPS, no access :(
...Aug 16 14:11:09 marto upsmon[7731]: Master privileges unavailable on UPS [Inform@localhost]
Aug 16 14:11:09 marto upsmon[7731]: Reason: Access denied
Can you tell me where my error is, my configuration files are:
ups.conf:
[Inform]
driver = powercom
port = /dev/ttyS0
desc = "inform guard"
linevoltage = 220
type = KIN1500AP
upsd.conf:
ACL all 0.0.0.0/0
ACL localhost 127.0.0.1/32
ACCEPT localhost
REJECT all
ups.users:
root
password = pwd
allowfrom = localhost
actions = SET
instcmds = ALL
marto
password = pwd
allowfrom = localhost
upsmon master
upsmon.conf:
MONITOR Inform@localhost 1 marto pwd ma...
2011 Jul 08
2
Ubuntu 10.04 Ultra 700VA UPS Setup Nut
...c-desktop kernel: [ 3049.671558] generic-usb
0003:0D9F:0004.0005: hiddev96,hidraw1: USB HID v1.00 Device [POWERCOM
Co.,LTD HID UPS Battery] on usb-0000:00:1d.0-1/input0
Here's my etc/nut/ups.conf file:
Code:
# /etc/nut/ups.conf
[Ultra]
driver = powercom
port = port=/dev/hidraw1
linevoltage = 120
manufacturer = Ultra
modelname = ULTRA 700VA
type = Trust
methodOfFlowControl=dtr0rts1
shutdownArguments = {{7,10},y}
Here's what I get when I run sudo upsdrvctl start:
Code:
eric at eric-desktop:~$ sudo upsdrvctl start
Network UPS Tools - UPS driver controller 2.4...
2005 Jul 06
0
Powercom BNT-1500AP
...quot;. But it seems that there is still missing
usablity. I was wondering if anybody found any better configs?
---- excerpt of ups.conf
[AVR1500]
driver = powercom
port = /dev/ttyS0
desc = "PowerCom BNT-1500AP"
modelname = "BNT-1500AP"
linevoltage = 120
type = KIN1500AP
--------------------------------------
2005 Jul 07
2
PowerCom Smart King SMK-1000
Hi!
I've tried the Fenton Driver for my UPS. The Powercom driver doesn't work.
Here is the results:
Network UPS Tools - UPS driver controller 2.0.0
Network UPS Tools - Fenton UPS driver 1.21 (2.0.0)
Unknown ups - please report this ID string: #PCM SMK-1000 2001
V9.0
Detected Unknown MK-1000 on /dev/ttyS0
Have you any ideas to make it compartible with NUT.
Thanks!
With
2007 Oct 04
0
Powercom black knight 800AP (serial)
Hi,
Nut versions: 2.2.0 and 2.0.2 (powercom -x type=KIN1500AP -x linevoltage=220)
I've got the above mentioned serial UPS and have found some problems using
it.
1) under linux 2.6.12 select() timed out on reading the serial port
in NONBLOCK mode.
Not sure about this one, seems most likely a kernel problem, since it's
working OK in 2.6.20. But on the other hand...
2005 Dec 30
2
BNT600AP
Hi,
I have a little problem with PowerCom BNT600AP after running driver I
see: root@rask> powercom -D /dev/ttyS1
Network UPS Tools - PowerCom and similars protocol UPS driver $
Revision: 0.5 $ (2.0.2)
debug level is '1'
Values of arguments:
manufacturer : 'PowerCom'
model name : 'Unknown'
serial number : 'Unknown'
line
2009 Nov 20
1
ULTRA 2000 ULT33046 configuration
...rg>.
#
# Driver failed to start (exit status=1)
[POWERCOM]
driver = powercom
port=/dev/serial/by-id/usb-POWERCOM_CO.__LTD._USB_to_Serial-if00-port0 # -> ../../ttyUSB0
manufacturer "PowerCom"
linevoltage "120"
modelname "RCD-UPS2000D"
serialnumber "40206430906"
type "ULT"
#
# This configuration's output:
# # upsdrvctl -u nut -D start POWERCOM
# Network UPS Tools - UPS driver controller 2.4.1...
2012 Jul 21
0
Re Powercom Vanguard driver for nut
...d
Driver failed to start (exit status=1)
?
Nut version
nut-2.2.2-3.el5
on kernel
2.6.18-308.11.1.el5PAE
?
If we try using the powercom driver it complains it is a usbhid-ups and if we try some of the powercom settings in the ups.conf the usbhid-ups driver rejects them as unknown (ie) model = , linevoltage = ....
?
lsusb -vd 0d9f:0004|sed -ne '/^\w/p;/\bi/p'? returns
Protocol spec without prior Class and Subclass spec at line 4297
Bus 005 Device 002: ID 0d9f:0004 Powercom Co., Ltd
Device Descriptor:
? idVendor?????????? 0x0d9f Powercom Co., Ltd
? idProduct????????? 0x0004
? iManufacturer???...