search for: guestimation

Displaying 20 results from an estimated 64 matches for "guestimation".

Did you mean: guesstimation
2017 Jun 16
2
Help with Elite 800VA usb UPS
...l start Network UPS Tools - UPS driver controller 2.7.2 Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2) Supported UPS detected with megatec protocol Rating information unavailable Vendor information unavailable No values provided for battery high/low voltages in ups.conf Using 'guestimation' (low: -0.866667, high: -1.083333)! Initial battery charge undetermined Driver failed to start (exit status=1) What should I do? Thanks again, Andrea 2017-06-12 12:34 GMT+02:00 Manuel Wolfshant <wolfy at nobugconsulting.ro>: > On 06/12/2017 12:56 PM, Andrea de Lutti wrote: > &gt...
2017 Jun 12
2
Help with Elite 800VA usb UPS
...strange values for battery.voltage.high and > battery.voltage.low....are they correct? > > run with a test load ( at least twice, for 50% and 100% load for > instance ) and write down the periods between full charge and shutdown. > Then you can use runtimecal in ups.conf to obtain guestimations during > normal usage > -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20170612/a5e339dd/attachment.html>
2017 Jun 12
3
Help with Elite 800VA usb UPS
> > > root at artu:~# upsc Elit at artu > > Init SSL without certificate database > > battery.voltage: 13.90 > > battery.voltage.high: -1.08 > > battery.voltage.low: -0.87 > > device.type: ups > > driver.name: blazer_usb > > driver.parameter.pollinterval: 2 > > driver.parameter.port: auto > > driver.version: 2.7.2 > >
2017 Jun 07
2
Help with Elite 800VA usb UPS
...l start Network UPS Tools - UPS driver controller 2.7.2 Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2) Supported UPS detected with megatec protocol Rating information unavailable Vendor information unavailable No values provided for battery high/low voltages in ups.conf Using 'guestimation' (low: -0.866667, high: -1.083333)! Battery runtime will not be calculated (runtimecal not set) Thank you lots, Andrea -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20170607/334afbbd/attachme...
2007 Sep 24
2
Asterisk 1.4.12 Release?
Hi All, I read rumors of a potential Asterisk 1.4.12 release for last week. I would like to start testing Asterisk 1.4 on Solaris, but, the fix for the segfault in res_features is only in the current development trunk. I would much rather test a release version, and as such, need to wait for the release of 1.4.12, my question is, do we have a guestimate on when it will be released, 1 week, 2
2017 Jun 10
2
Help with Elite 800VA usb UPS
...l start Network UPS Tools - UPS driver controller 2.7.2 Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2) Supported UPS detected with megatec protocol Rating information unavailable Vendor information unavailable No values provided for battery high/low voltages in ups.conf Using 'guestimation' (low: -0.866667, high: -1.083333)! Battery runtime will not be calculated (runtimecal not set) but root at artu:~# upsc Elit at artu Error: Connection failure: Connection refused Starting the driver with debug level 5 seems happier, but continue to cycle root at artu:~# /lib/nut/blazer_usb...
2017 Jun 14
0
Help with Elite 800VA usb UPS
...l start Network UPS Tools - UPS driver controller 2.7.2 Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2) Supported UPS detected with megatec protocol Rating information unavailable Vendor information unavailable No values provided for battery high/low voltages in ups.conf Using 'guestimation' (low: -0.866667, high: -1.083333)! Initial battery charge undetermined Driver failed to start (exit status=1) What should I do? Thanks again, Andrea 2017-06-12 17:34 GMT+02:00 Andrea de Lutti <adelutti at gmail.com>: > Thanks a lot, I will do it and keep you informed. > Best...
2006 Dec 06
2
same bitstream
Narrowband (8 kHz), wideband (16 kHz), and ultra-wideband (32 kHz) compression in the same bitstream What is the meaning of this? can i find more information about this somewhere? And what is packel loss concealment, an you enable this somewhere? thanks! -------------- next part -------------- An HTML attachment was scrubbed... URL:
2000 Aug 11
2
Vorbis optimizations...
I was wondering about what the near and longer term future directions for optimization of Vorbis decompression are. I am interested in using it as a replacement for MP3. But it seems at this point (not certain about this) that Vorbis doesn't really have much optimization implemented yet. By this I mean, for example, implementing something like MMX x86 optimzations in order to speed up the
2017 Jun 11
3
Help with Elite 800VA usb UPS
...l start Network UPS Tools - UPS driver controller 2.7.2 Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2) Supported UPS detected with megatec protocol Rating information unavailable Vendor information unavailable No values provided for battery high/low voltages in ups.conf Using 'guestimation' (low: -0.866667, high: -1 root at artu:~# upsd -c reload Network UPS Tools upsd 2.7.2 .083333)! Battery runtime will not be calculated (runtimecal not set) root at artu:~# upsc Elit at artu Init SSL without certificate database battery.voltage: 13.90 battery.voltage.high: -1.08 battery.volt...
2017 Nov 14
2
str() not displaying names
In some cases, str() does not print the "names" attribute of the object: u <- structure(c(5, 6), names = c("a", "b"), color = "blue") str(u) # atomic [1:2] 5 6 # - attr(*, "color")= chr "blue" Is it a bug or a design choice? Originally asked here: https://stackoverflow.com/q/47185756/6656269
2004 Jun 29
6
Encoding theora...
Just trying to debug my theora encoder... just wondering if someone could give me some insight on a few thigns... In the yuv_buffer i'm sending in... i am just setting y_stride = y_width = videoWidth uv_stride = videoWidth/2 y_height = videoHeight uv_height = videoHeight/2 Making the y buffer (width*height) and each of u and v (width*height/4) Am i correct in doing this ? I knwo stride
2017 Jun 16
3
Help with Elite 800VA usb UPS
...have only to make a deep test. Is there a way to add a NOTIFYMSG value for the battery test? Thank you lots Andrea 2017-06-16 14:50 GMT+02:00 Charles Lepple <clepple at gmail.com>: > On Jun 16, 2017, at 2:20 AM, Andrea de Lutti <adelutti at gmail.com> wrote: > > Using 'guestimation' (low: -0.866667, high: -1.083333)! > > Initial battery charge undetermined > > Driver failed to start (exit status=1) > > The "low" and "high" voltages should correspond to the battery voltage > when it is discharged (LB) and charged, respectively. For...
2015 Jul 14
1
New questions
...E]root at debian:/home/john# upsdrvctl startNetwork UPS Tools - UPS driver controller 2.7.2Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2)Supported UPS detected with megatec protocolVendor information unavailableNo values provided for battery high/low voltages in ups.conf Using 'guestimation' (low: 10.400000, high: 13.000000)!Battery runtime will not be calculated (runtimecal not set)[CODE] I recall, from past experience with this UPS, that the nominal voltage is around 13.1 . ?I have?no idea what the low voltage should be, but 10.4 is probably okay. So, would I add the following?i...
2013 Aug 11
2
N-Power MEV-3000LT compatibility report and problem
...50 input.voltage: 209.8 input.voltage.fault: 225.1 input.voltage.nominal: 230 output.voltage: 230.7 ups.beeper.status: enabled ups.delay.shutdown: 30 ups.delay.start: 180 ups.load: 15 ups.status: OL ups.temperature: 41.5 ups.type: online Now I would elaborate the config and make use of the runtime guestimation. I added the following lines: runtimecal = 2000,100,5000,50 chargetime = 86400 default.battery.voltage.high = 109.6 default.battery.voltage.low = 84.4 default.battery.capacity = 40 I didn't do any measuerements yet and these data are based solely on the datasheet of my batteries and common se...
2012 Feb 13
3
RFC: new variable battery.status (was: [PATCH] upscode2: Report ABM Status)
2012/2/6 thomas schorpp <thomas.schorpp at googlemail.com>: > Hi, Hi Thomas, > I want the driver report the battery status from ABM charging controllers > -patch attached- : thanks for your patch. since it introduces a new variable (battery.status.abm), I prefer to step back and think to something useful more widely. thus, I'm thinking about a generic
2014 Nov 04
2
RFC: new variable battery.status
THANKYOUTHANKYOUTHANKYOUTHANKYOU!!!!!! There was a smaller patch posted to the list for lines -1389,9 +1390,10 a couple years ago, it helped some - BUT - it was still buggy. I have a Compaq R3000, I will get this patch integrated pronto and test Note that since the UPS relies on the voltage from the battery pack to determine state of charge, it is quite useful to add in the battery pack
2012 Dec 04
0
[LLVMdev] Minimum Python Version
On Mon, Dec 3, 2012 at 8:49 PM, Duncan Sands <baldrick at free.fr> wrote: > Lenny came out in 2009, and > was the latest stable Debian release until 6 months ago, so it's not even > that > old. To put that in perspective, Lenny was released around r64555. That's pretty old. On Mon, Dec 3, 2012 at 8:49 PM, Duncan Sands <baldrick at free.fr> wrote: > What is the
2015 Dec 11
0
need help for shutdown (windows)
...reply 1.281643 Vendor information read 2 failed 1.422270 blazer_vendor: short reply 1.422270 Vendor information read 3 failed 1.437881 Vendor information unavailable 1.437881 No values provided for battery high/low voltages in ups.conf 1.453506 Using 'guestimation' (low: 10.400000, high: 13.000000)! 1.469132 Battery runtime will not be calculated (runtimecal not set) 1.799942 blazer_status: non numerical value [--.-] 1.815575 dstate_init: sock \\.\pipe\blazer_usb-myups open on fd 260 2.143719 blazer_status: non numerical value...
2017 Jun 08
0
Help with Elite 800VA usb UPS
...ver controller 2.7.2 > Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2) > Supported UPS detected with megatec protocol > Rating information unavailable > Vendor information unavailable > No values provided for battery high/low voltages in ups.conf > > Using 'guestimation' (low: -0.866667, high: -1.083333)! > Battery runtime will not be calculated (runtimecal not set) What does "upsc" show for this UPS? Note that the blazer_usb driver is no longer maintained. Its replacement is nutdrv_qx: http://networkupstools.org/docs/man/nutdrv_qx.html