Displaying 20 results from an estimated 64 matches for "guestim".
Did you mean:
guestid
2017 Jun 16
2
Help with Elite 800VA usb UPS
...l start
Network UPS Tools - UPS driver controller 2.7.2
Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2)
Supported UPS detected with megatec protocol
Rating information unavailable
Vendor information unavailable
No values provided for battery high/low voltages in ups.conf
Using 'guestimation' (low: -0.866667, high: -1.083333)!
Initial battery charge undetermined
Driver failed to start (exit status=1)
What should I do?
Thanks again,
Andrea
2017-06-12 12:34 GMT+02:00 Manuel Wolfshant <wolfy at nobugconsulting.ro>:
> On 06/12/2017 12:56 PM, Andrea de Lutti wrote:
>...
2017 Jun 12
2
Help with Elite 800VA usb UPS
...strange values for battery.voltage.high and
> battery.voltage.low....are they correct?
>
> run with a test load ( at least twice, for 50% and 100% load for
> instance ) and write down the periods between full charge and shutdown.
> Then you can use runtimecal in ups.conf to obtain guestimations during
> normal usage
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20170612/a5e339dd/attachment.html>
2017 Jun 12
3
Help with Elite 800VA usb UPS
>
> > root at artu:~# upsc Elit at artu
> > Init SSL without certificate database
> > battery.voltage: 13.90
> > battery.voltage.high: -1.08
> > battery.voltage.low: -0.87
> > device.type: ups
> > driver.name: blazer_usb
> > driver.parameter.pollinterval: 2
> > driver.parameter.port: auto
> > driver.version: 2.7.2
> >
2017 Jun 07
2
Help with Elite 800VA usb UPS
...l start
Network UPS Tools - UPS driver controller 2.7.2
Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2)
Supported UPS detected with megatec protocol
Rating information unavailable
Vendor information unavailable
No values provided for battery high/low voltages in ups.conf
Using 'guestimation' (low: -0.866667, high: -1.083333)!
Battery runtime will not be calculated (runtimecal not set)
Thank you lots,
Andrea
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20170607/334afbbd/att...
2007 Sep 24
2
Asterisk 1.4.12 Release?
...1.4.12 release for last week. I
would like to start testing Asterisk 1.4 on Solaris, but, the fix for
the segfault in res_features is only in the current development trunk. I
would much rather test a release version, and as such, need to wait for
the release of 1.4.12, my question is, do we have a guestimate on when
it will be released, 1 week, 2 weeks, a month?
Thanks
Bruce
-------------- next part --------------
A non-text attachment was scrubbed...
Name: bruce.mcalister.vcf
Type: text/x-vcard
Size: 264 bytes
Desc: not available
Url : http://lists.digium.com/pipermail/asterisk-users/attachments/2...
2017 Jun 10
2
Help with Elite 800VA usb UPS
...l start
Network UPS Tools - UPS driver controller 2.7.2
Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2)
Supported UPS detected with megatec protocol
Rating information unavailable
Vendor information unavailable
No values provided for battery high/low voltages in ups.conf
Using 'guestimation' (low: -0.866667, high: -1.083333)!
Battery runtime will not be calculated (runtimecal not set)
but
root at artu:~# upsc Elit at artu
Error: Connection failure: Connection refused
Starting the driver with debug level 5 seems happier, but continue to cycle
root at artu:~# /lib/nut/blaze...
2017 Jun 14
0
Help with Elite 800VA usb UPS
...l start
Network UPS Tools - UPS driver controller 2.7.2
Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2)
Supported UPS detected with megatec protocol
Rating information unavailable
Vendor information unavailable
No values provided for battery high/low voltages in ups.conf
Using 'guestimation' (low: -0.866667, high: -1.083333)!
Initial battery charge undetermined
Driver failed to start (exit status=1)
What should I do?
Thanks again,
Andrea
2017-06-12 17:34 GMT+02:00 Andrea de Lutti <adelutti at gmail.com>:
> Thanks a lot, I will do it and keep you informed.
>...
2006 Dec 06
2
same bitstream
Narrowband (8 kHz), wideband (16 kHz), and ultra-wideband (32 kHz)
compression in the same bitstream
What is the meaning of this? can i find more information about this
somewhere?
And what is packel loss concealment, an you enable this somewhere?
thanks!
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
2000 Aug 11
2
Vorbis optimizations...
...sing it as a replacement for MP3. But it
seems at this point (not certain about this) that Vorbis doesn't
really have much optimization implemented yet. By this I
mean, for example, implementing something like MMX x86
optimzations in order to speed up the decompression.
At this point, rough guestimates suggest that Vorbis uses
up about 2x the CPU cycles on a PC to decompress relative
to MP3.
What are the possibilities and what is the plan? I (we) might
actually be able to contribute to this effort, as we might
stand to benefit from it.
Paul
--- >8 ----
List archives: http://www.xiph...
2017 Jun 11
3
Help with Elite 800VA usb UPS
...l start
Network UPS Tools - UPS driver controller 2.7.2
Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2)
Supported UPS detected with megatec protocol
Rating information unavailable
Vendor information unavailable
No values provided for battery high/low voltages in ups.conf
Using 'guestimation' (low: -0.866667, high: -1
root at artu:~# upsd -c reload
Network UPS Tools upsd 2.7.2
.083333)!
Battery runtime will not be calculated (runtimecal not set)
root at artu:~# upsc Elit at artu
Init SSL without certificate database
battery.voltage: 13.90
battery.voltage.high: -1.08
battery...
2017 Nov 14
2
str() not displaying names
In some cases, str() does not print the "names" attribute of the object:
u <- structure(c(5, 6), names = c("a", "b"), color = "blue")
str(u)
# atomic [1:2] 5 6
# - attr(*, "color")= chr "blue"
Is it a bug or a design choice?
Originally asked here:
https://stackoverflow.com/q/47185756/6656269
2004 Jun 29
6
Encoding theora...
Just trying to debug my theora encoder... just wondering if someone could
give me some insight on a few thigns...
In the yuv_buffer i'm sending in... i am just setting
y_stride = y_width = videoWidth
uv_stride = videoWidth/2
y_height = videoHeight
uv_height = videoHeight/2
Making the y buffer (width*height) and each of u and v (width*height/4)
Am i correct in doing this ? I knwo stride
2017 Jun 16
3
Help with Elite 800VA usb UPS
...have only to make a deep test.
Is there a way to add a NOTIFYMSG value for the battery test?
Thank you lots
Andrea
2017-06-16 14:50 GMT+02:00 Charles Lepple <clepple at gmail.com>:
> On Jun 16, 2017, at 2:20 AM, Andrea de Lutti <adelutti at gmail.com> wrote:
> > Using 'guestimation' (low: -0.866667, high: -1.083333)!
> > Initial battery charge undetermined
> > Driver failed to start (exit status=1)
>
> The "low" and "high" voltages should correspond to the battery voltage
> when it is discharged (LB) and charged, respectively....
2015 Jul 14
1
New questions
...E]root at debian:/home/john# upsdrvctl startNetwork UPS Tools - UPS driver controller 2.7.2Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2)Supported UPS detected with megatec protocolVendor information unavailableNo values provided for battery high/low voltages in ups.conf
Using 'guestimation' (low: 10.400000, high: 13.000000)!Battery runtime will not be calculated (runtimecal not set)[CODE]
I recall, from past experience with this UPS, that the nominal voltage is around 13.1 . ?I have?no idea what the low voltage should be, but 10.4 is probably okay. So, would I add the follow...
2013 Aug 11
2
N-Power MEV-3000LT compatibility report and problem
...50
input.voltage: 209.8
input.voltage.fault: 225.1
input.voltage.nominal: 230
output.voltage: 230.7
ups.beeper.status: enabled
ups.delay.shutdown: 30
ups.delay.start: 180
ups.load: 15
ups.status: OL
ups.temperature: 41.5
ups.type: online
Now I would elaborate the config and make use of the runtime guestimation.
I added the following lines:
runtimecal = 2000,100,5000,50
chargetime = 86400
default.battery.voltage.high = 109.6
default.battery.voltage.low = 84.4
default.battery.capacity = 40
I didn't do any measuerements yet and these data are based solely on the datasheet of
my batteries and comm...
2012 Feb 13
3
RFC: new variable battery.status (was: [PATCH] upscode2: Report ABM Status)
...ce.mfr: Compaq
> device.model: UPS 1000 VA FW -0026
> device.serial: E00230050
>
> My UPS does not support UPBS cmd, but its responses are not very useful
> anyway.
as mentioned in the manpage and source code, no battery.charge data is
returned from the device.
"the driver will guestimate a value based on the nominal battery
min/max and the current battery voltage."
so it may be due to both.
It may also be a percentage of the nominal level, which may be not
reachable after some time.
cheers,
Arnaud
--
Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com
Net...
2014 Nov 04
2
RFC: new variable battery.status
...oltage.nominal: 24.00
>>> device.mfr: Compaq
>>> device.model: UPS 1000 VA FW -0026
>>> device.serial: E00230050
>
>>
>> as mentioned in the manpage and source code, no battery.charge data is
>> returned from the device.
>> "the driver will guestimate a value based on the nominal battery
>> min/max and the current battery voltage."
>
> Maybe I've found a better "guesstimation", -PATCH found cleaning up old
> stuff attached-
>
>>
>> so it may be due to both.
>> It may also be a percentage...
2012 Dec 04
0
[LLVMdev] Minimum Python Version
On Mon, Dec 3, 2012 at 8:49 PM, Duncan Sands <baldrick at free.fr> wrote:
> Lenny came out in 2009, and
> was the latest stable Debian release until 6 months ago, so it's not even
> that
> old.
To put that in perspective, Lenny was released around r64555. That's pretty old.
On Mon, Dec 3, 2012 at 8:49 PM, Duncan Sands <baldrick at free.fr> wrote:
> What is the
2015 Dec 11
0
need help for shutdown (windows)
...reply
1.281643 Vendor information read 2 failed
1.422270 blazer_vendor: short reply
1.422270 Vendor information read 3 failed
1.437881 Vendor information unavailable
1.437881 No values provided for battery high/low voltages in ups.conf
1.453506 Using 'guestimation' (low: 10.400000, high: 13.000000)!
1.469132 Battery runtime will not be calculated (runtimecal not set)
1.799942 blazer_status: non numerical value [--.-]
1.815575 dstate_init: sock \\.\pipe\blazer_usb-myups open on fd 260
2.143719 blazer_status: non numerical...
2017 Jun 08
0
Help with Elite 800VA usb UPS
...ver controller 2.7.2
> Network UPS Tools - Megatec/Q1 protocol USB driver 0.11 (2.7.2)
> Supported UPS detected with megatec protocol
> Rating information unavailable
> Vendor information unavailable
> No values provided for battery high/low voltages in ups.conf
>
> Using 'guestimation' (low: -0.866667, high: -1.083333)!
> Battery runtime will not be calculated (runtimecal not set)
What does "upsc" show for this UPS?
Note that the blazer_usb driver is no longer maintained. Its replacement is nutdrv_qx:
http://networkupstools.org/docs/man/nutdrv_qx.html