EATON 5PX with nut 2.6 on ubuntu 12.04
...'t known if its' the reaseon or if someone has change something but scripts no longer work I have a message "returned 2" Can you help me because I don't find how to solve this thanks Best regards sabine ----------------message d'origine----------------- De: "Sabine GOUDARD" sabine.goudard at st-etienne.archi.fr A: "Arnaud Quette" aquette.dev at gmail.com Date: Fri, 08 Mar 2013 08:46:19 +0100 ---------------------------------------------------------- > >Hello Arnaud >I almost managed to make everything work >my server isn't in produt...
2010 Dec 03
2
nut 2.4 et MGE 2200 (suite)
...nect ups on another PC I have the same problem I try a usb key lsusb is Bus 001 Device 018: ID 05dc:a701 Lexar Media, Inc. JumpDrive FireFly Bus 001 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Is it possible my usb port is HS on my UPS What can I do Thanks for your help -- Sabine GOUDARD - Informatique et Multim?dia Ecole Nationale Sup?rieure d?Architecture de Saint-?tienne 1, rue Buisson BP 94 42003 Saint-?tienne Cedex 1 T?l. : 04 77 42 37 20 - Fax : 04 77 42 35 40 sabine.goudard at st-etienne.archi.fr
2010 Nov 29
3
nut 2.4 et MGE 2200
...FYMSG ONLINE "UPS %s on line power" NOTIFYMSG ONBATT "UPS %s on battery" NOTIFYFLAG ONBATT SYSLOG+WALL+EXEC NOTIFYFLAG ONLINE SYSLOG+WALL+EXEC when the server stops, the log is not generated and Same with upssched ... where can I seach ? Thank you for your help -- Sabine GOUDARD - Informatique et Multim?dia Ecole Nationale Sup?rieure d?Architecture de Saint-?tienne 1, rue Buisson BP 94 42003 Saint-?tienne Cedex 1 T?l. : 04 77 42 37 20 - Fax : 04 77 42 35 40 sabine.goudard at st-etienne.archi.fr
2010 Dec 17
3
Comet EXtreme 6 and mge-utalk
Hi Sabine and Christoph, I've just committed a few changes to mge-utalk (r2749). can you please try a snapshot and report back the results: http://new.networkupstools.org/download.html#Snapshots cheers, Arnaud -- Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/ Debian Developer -
2010 Dec 07
1
nut 2.4 et MGE CometEXtrem 6
...etEX] (mge-utalk-MGE_cometEX): No such file or directory or Network UPS Tools - UPS driver controller 2.4.3 Network UPS Tools - MGE UPS SYSTEMS/U-Talk driver 0.89 (2.4.3) /dev/ttyS0 is locked by another process Driver failed to start (exit status=1) Thanks for your help -- Sabine GOUDARD - Informatique et Multim?dia Ecole Nationale Sup?rieure d?Architecture de Saint-?tienne 1, rue Buisson BP 94 42003 Saint-?tienne Cedex 1 T?l. : 04 77 42 37 20 - Fax : 04 77 42 35 40 sabine.goudard at st-etienne.archi.fr -------------- next part -------------- An HTML attachment was scrubbed......
2013 Apr 18
0
Nut-upsuser Digest, Vol 94, Issue 18
...an.org You can reach the person managing the list at nut-upsuser-owner at lists.alioth.debian.org When replying, please edit your Subject line so it is more specific than "Re: Contents of Nut-upsuser digest..." Today's Topics: 1. problem with a script via upssched-cmd (Sabine GOUDARD) ---------------------------------------------------------------------- Message: 1 Date: Thu, 18 Apr 2013 12:42:22 +0200 From: Sabine GOUDARD <sabine.goudard at st-etienne.archi.fr> To: nut <nut-upsuser at lists.alioth.debian.org> Subject: [Nut-upsuser] problem with a script via upss...
2012 Mar 20
2
MGE Pulsar evolution 2200
Hello, I forgot nut since more than a year because a lot of job with other application My server nut failed since severals months We had 3 electric failure so I must install a new server nut I work with ubuntu 10.04.4 (64bits) / I installed nut 2.4.3 with deposits I have a MGE Pulsar evolution 2200 connected on usb last week when I began my tests all was ok (communication etc etc ..)
2007 Nov 15
0
somme trouble with ups mge pulsar M2200 and mandriva 2007 with nu t 2.2
...ow, I had change ups name and user name in ups.conf, upsd.users, upsmon.conf etc etc ... but I have quickly these events in my syslog without doing anyting what can I do ? Nov 15 11:09:22 mezenc upsmon[3865]: Poll UPS [pm2200 at localhost] failed - Data stale thanks a lot for your help Sabine GOUDARD Ecole Nationale Suprieure d'Architecture de St Etienne Service Informatique 7 rue Etienne Dolet 42000 Saint-Etienne mailto:sabine.goudard at st-etienne.archi.fr
2007 Nov 13
1
trouble with ups mge evolution2200 and mandriva 2007 - nut 2. 2 + PSP
...ors Nov 13 11:09:22 mezenc upsmon[3865]: Poll UPS [mgeups at localhost] failed - Data stale it happens when daemon upsd et upsmon are started after the boot obviously, there isn't any errors when upsd and upsmon are started at boot following later ... -----Message d'origine----- De : goudard sabine Envoy? : mardi 13 novembre 2007 11:24 ? : 'aquette.dev at gmail.com' Cc : 'nut-upsuser at lists.alioth.debian.org' Objet : trouble with ups mge evolution2200 and mandriva 2007 - nut 2.2 + PSP Hello, I'll be back with my MGE Evolution 2200 connected with RS232 I upgra...
2012 Dec 12
1
EATON 5PX with nut 2.6 on ubuntu 12.04
Hello, I have a EATON 5PX with a Network Management Card on ubuntu 12.04 I established a shutdown procedure like described in rogerprice.org It works I have an event mail on "onbatt" then another on "onbattdelay1" then the "upsmon -c fsd" order on "onbattedelay2" When "onbattdelay2" is finished, my server execute "auto logout and shutdown
2007 Oct 16
1
trouble with ups mge evolution2200 and mandriva 2007 - nut 2.01
...utdown -h now" NOTIFYCMD /etc/ups/upsalert POWERDOWNFLAG /etc/ups/killpower NOTIFYMSG ONBATT "L'onduleur %s est sur batterie" NOTIFYMSG ONLINE "L'onduleur %s est aliment?" NOTIFYFLAG ONBATT SYSLOG+EXEC NOTIFYFLAG ONLINE SYSLOG+EXEC thanks for your help Sabine GOUDARD Ecole Nationale Sup?rieure d'Architecture de St Etienne Service Informatique 7 rue Etienne Dolet 42000 Saint-Etienne mailto:sabine.goudard at st-etienne.archi.fr
2013 Apr 18
0
problem with a script via upssched-cmd
...indows -U login%passwd ssh login at ip_ubuntu sudo shutdown -h now If I run only this cde net rpc shutdown -f -I ip_windows -U login%passwd it's ok if I run only this cde ssh login at ip_ubuntu sudo /sbin/shutdown -h now I have returned 255 Is someone can help me Thanks a lot -- Sabine Goudard Service Informatique et Multim?dia T?l : 04 77 42 37 20 Ecole Nationale Sup?rieure d?Architecture de Saint-?tienne 1, rue Buisson BP 94 42003 Saint-?tienne Cedex 1 Fax : 04 77 42 35 40 [http://www.st-etienne.archi.fr -> http://www.st-etienne.archi.fr] -------------- next part -------------- An...
2007 Nov 13
0
trouble with ups mge evolution2200 and mandriva 2007 - nut 2.2 + PSP
...vent Nov 13 11:09:22 mezenc upsmon[3865]: Poll UPS [mgeups at localhost] failed - Data stale Nov 13 11:09:27 mezenc upsmon[3865]: Poll UPS [mgeups at localhost] failed - Data stale and my server shut down what can I do ? Thanks for your help -----Message d'origine----- De: Arnaud Quette A: goudard sabine Cc: Arjen de Korte; nut-upsuser at lists.alioth.debian.org Date: 25/10/2007 23:06 Objet: Re: [Nut-upsuser] trouble with ups mge evolution2200 and mandriva 2007 - nut 2.01 Bonjour Sabine, I'll add some more comments to Arjen's answer. 2007/10/16, Arjen de Korte <nut+users at de-...