2005 Jul 22
1
Another HID USB UPS
...AlarmControl Path: UPS.Battery.APCBattReplaceDate Path: UPS.Battery.ManufacturerDate Path: UPS.Battery.RemainingCapacity Path: UPS.Battery.RunTimeToEmpty Path: UPS.Battery.RunTimeToEmpty Path: UPS.Battery.RemainingTimeLimit Path: UPS.Battery.ConfigVoltage Path: UPS.Battery.Voltage Path: UPS.Battery.ff860024 Path: UPS.ff860018.Input Path: UPS.ff860018.ConfigVoltage Path: UPS.ff860018.Voltage Path: UPS.ff860018.LowVoltageTransfer Path: UPS.ff860018.HighVoltageTransfer Path: UPS.ff860018.ff860024 Path: UPS.ff860018.ff860061 Path: UPS.APC860052.APCGeneralCollection Path: UPS.APC860052.APCForceShutdown Pat...
2005 Aug 02
0
newhidups for APC Back-UPS ES 650
...AlarmControl Path: UPS.Battery.APCBattReplaceDate Path: UPS.Battery.ManufacturerDate Path: UPS.Battery.RemainingCapacity Path: UPS.Battery.RunTimeToEmpty Path: UPS.Battery.RunTimeToEmpty Path: UPS.Battery.RemainingTimeLimit Path: UPS.Battery.ConfigVoltage Path: UPS.Battery.Voltage Path: UPS.Battery.ff860024 Path: UPS.ff860018.Input Path: UPS.ff860018.ConfigVoltage Path: UPS.ff860018.Voltage Path: UPS.ff860018.LowVoltageTransfer Path: UPS.ff860018.HighVoltageTransfer Path: UPS.ff860018.ff860024 Path: UPS.ff860018.ff860061 Path: UPS.APC860052.APCGeneralCollection Path: UPS.APC860052.APCForceShutdown Pat...
2005 Aug 26
0
NUT patches
...APCBattReplaceDate Path: UPS.Battery.ManufacturerDate Path: UPS.Battery.RemainingCapacity Path: UPS.Battery.RunTimeToEmpty Path: UPS.Battery.RunTimeToEmpty (NOTE: ### HERE) Path: UPS.Battery.RemainingTimeLimit Path: UPS.Battery.ConfigVoltage Path: UPS.Battery.Voltage Path: UPS.Battery.ff860024 Path: UPS.ff860018.Input Path: UPS.ff860018.ConfigVoltage Path: UPS.ff860018.Voltage Path: UPS.ff860018.LowVoltageTransfer Path: UPS.ff860018.HighVoltageTransfer Path: UPS.ff860018.ff860024 Path: UPS.ff860018.ff860061 Path: UPS.APC860052.APCGeneralCollection Path: UPS.APC860052.APCForceShutdown Pat...
2012 Aug 30
1
Data stale and Back UPS ES
...Offset: 0, Size: 8, Value: 137 3.603606 Report[get]: (5 bytes) => 62 00 01 02 03 3.619206 Path: UPS.ff860001.ff860025, Type: Feature, ReportID: 0x62, Offset: 0, Size: 32, Value: 5.0463e+007 3.634806 Report[get]: (2 bytes) => 51 84 3.634806 Path: UPS.PowerConverter.ff860024, Type: Feature, ReportID: 0x51, Offset: 0, Size: 8, Value: 132 3.650406 Report descriptor retrieved (Reportlen = 1144) 3.666007 Found HID device 3.666007 Detected a UPS: American Power Conversion/Back-UPS ES 525 FW:851.t3.I USB FW:t3 3.681607 libusb_get_report: libusb0-d...
2006 Feb 08
2
2.0.3-pre2: Spurious UPS UPS@localhost battery is
Peter Selinger wrote: > Hm. I need more information, as NUT seems to garble the values even > before I can see them. I am not so worried about the date and > temperatures (although, strangely, the battery replacement date > appears to be Sept 25, 2001, which makes no sense). But the voltage is > definitely important. > > [...] > Thanks Peter - I'll send the new
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...0x24, Offset: 0, Size: 16, Value: 120 > 0.069783 Path: UPS.Battery.ConfigVoltage, Type: Feature, ReportID: 0x25, Offset: 0, Size: 16, Value: 12 > 0.070424 Path: UPS.Battery.Voltage, Type: Feature, ReportID: 0x26, Offset: 0, Size: 16, Value: 12.59 > 0.071043 Path: UPS.Battery.ff860024, Type: Feature, ReportID: 0x27, Offset: 0, Size: 16, Value: 247 > 0.071667 Path: UPS.Battery.ff860018, Type: Feature, ReportID: 0x28, Offset: 0, Size: 32, Value: -1.34135e+09 > 0.072280 Path: UPS.Input.ConfigVoltage, Type: Feature, ReportID: 0x30, Offset: 0, Size: 8, Value: 230 >...
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...set: 0, Size: 16, Value: 120 >> 0.069783 Path: UPS.Battery.ConfigVoltage, Type: Feature, ReportID: 0x25, Offset: 0, Size: 16, Value: 12 >> 0.070424 Path: UPS.Battery.Voltage, Type: Feature, ReportID: 0x26, Offset: 0, Size: 16, Value: 12.59 >> 0.071043 Path: UPS.Battery.ff860024, Type: Feature, ReportID: 0x27, Offset: 0, Size: 16, Value: 247 >> 0.071667 Path: UPS.Battery.ff860018, Type: Feature, ReportID: 0x28, Offset: 0, Size: 32, Value: -1.34135e+09 >> 0.072280 Path: UPS.Input.ConfigVoltage, Type: Feature, ReportID: 0x30, Offset: 0, Size: 8, Value: 23...
2009 Mar 13
7
Weird Load and Battery Temp Readings
I've acquired and installed NUT 2.4.1 on a D-Link DNS323 NAS. With exception of Load and Battery Temp readings all works well. A upsc ups at localhost command returns; battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 50 battery.date: 2001/09/25 battery.mfr.date: 2008/06/05 battery.runtime: 2122 battery.runtime.low: 120 battery.temperature: 3022999999999998800 battery.type:
2012 Apr 09
2
libusb_get_report: Unknown error
...ltage, Type: Feature, ReportID: 0x1f, Offset: 0, Size: 16, Value: 12 0.992479 Report[get]: (3 bytes) => 1d 3f 05 0.992504 Path: UPS.Battery.Voltage, Type: Feature, ReportID: 0x1d, Offset: 0, Size: 16, Value: 13.43 0.998458 Report[get]: (2 bytes) => 47 f4 0.998467 Path: UPS.Battery.ff860024, Type: Feature, ReportID: 0x47, Offset: 0, Size: 8, Value: 244 1.004458 Report[get]: (5 bytes) => 48 06 94 0c 10 1.004466 Path: UPS.Battery.ff860018, Type: Feature, ReportID: 0x48, Offset: 0, Size: 32, Value: 0 1.010493 refresh_report_buffer: expected 5 bytes, but got 3 instead 1.010...
2020 Sep 03
2
UPS reboots with APC UPS
...ure, ReportID: 0x24, Offset: 0, Size: 16, Value: 120 0.671407 Path: UPS.Battery.ConfigVoltage, Type: Feature, ReportID: 0x25, Offset: 0, Size: 16, Value: 24 0.676397 Path: UPS.Battery.Voltage, Type: Feature, ReportID: 0x26, Offset: 0, Size: 16, Value: 27.09 0.680414 Path: UPS.Battery.ff860024, Type: Feature, ReportID: 0x27, Offset: 0, Size: 8, Value: 241 0.684411 Path: UPS.Battery.ff860018, Type: Feature, ReportID: 0x28, Offset: 0, Size: 32, Value: 0 0.687357 Path: UPS.Input.ConfigVoltage, Type: Feature, ReportID: 0x30, Offset: 0, Size: 8, Value: 230 0.692379 Path: UPS.In...
2013 Aug 07
1
FreeNAS , NUT and APC BK500EI problem.
...026, Type: Feature, ReportID: 0x61, Offset: 0, Size: 8, Value: 10 1.126991 Report[get]: (5 bytes) => 62 00 01 02 03 1.127026 Path: UPS.ff860001.ff860025, Type: Feature, ReportID: 0x62, Offset: 0, Size: 32, Value: 0 1.130990 Report[get]: (2 bytes) => 51 94 1.131024 Path: UPS.PowerConverter.ff860024, Type: Feature, ReportID: 0x51, Offset: 0, Size: 8, Value: 148 1.131060 Report descriptor retrieved (Reportlen = 1217) 1.131068 Found HID device 1.131074 Detected a UPS: American Power Conversion/Back-UPS CS 500 FW:808.q10 .I USB FW:q10 1.131116 Report[buf]: (2 bytes) => 0c 64 1.131129 Pat...
2005 Aug 25
3
Tr : NUT patches
...to be useless anyway. 4) nut-cvs-patch-NUMPATH-2005-08-24 ---------------------------------------- This patch extends the function hid_lookup_usage() so that path names can also be looked up by numerical values. This is just a convenience - it allows one to put stuff like "UPS.PowerConverter.ff860024" in the apc-hid.h while testing device variables whose purpose is yet unknown. 5) nut-cvs-patch-DEP-2005-08-24 ---------------------------------------- This is just a convenience; I added proper dependencies to drivers/Makefile.in. I noticed that when I edited a *.h file, make would never re...