search for: ff860001

Displaying 10 results from an estimated 10 matches for "ff860001".

Did you mean: ff000001
2012 Aug 30
1
Data stale and Back UPS ES
...0.187200 HID descriptor, method 1: (9 bytes) => 09 21 10 01 21 01 22 78 04 0.202800 HID descriptor, method 2: (9 bytes) => 09 21 10 01 21 01 22 78 04 0.218400 HID descriptor length 1144 ... 3.556806 Report[get]: (3 bytes) => 60 00 00 3.556806 Path: UPS.ff860001.ff860023, Type: Feature, ReportID: 0x60, Offset: 0, Size: 16, Value: 0 3.588006 Report[get]: (2 bytes) => 61 89 3.588006 Path: UPS.ff860001.ff860026, Type: Feature, ReportID: 0x61, Offset: 0, Size: 8, Value: 137 3.603606 Report[get]: (5 bytes) => 62 00 01 02 03 3.61920...
2013 Aug 07
1
FreeNAS , NUT and APC BK500EI problem.
...entStatus.ff860080, Type: Input, ReportID: 0x33, Offset: 12, Size: 1, Value: 0 1.115430 Report[buf]: (3 bytes) => 33 0c 00 1.115438 Path: UPS.PresentStatus.ff860080, Type: Feature, ReportID: 0x33, Offset: 12, Size: 1, Value: 0 1.118990 Report[get]: (3 bytes) => 60 00 00 1.119025 Path: UPS.ff860001.ff860023, Type: Feature, ReportID: 0x60, Offset: 0, Size: 16, Value: 0 1.122998 Report[get]: (2 bytes) => 61 0a 1.123078 Path: UPS.ff860001.ff860026, Type: Feature, ReportID: 0x61, Offset: 0, Size: 8, Value: 10 1.126991 Report[get]: (5 bytes) => 62 00 01 02 03 1.127026 Path: UPS.ff860001....
2005 Aug 26
0
NUT patches
...oltageTransfer Path: UPS.ff860018.HighVoltageTransfer Path: UPS.ff860018.ff860024 Path: UPS.ff860018.ff860061 Path: UPS.APC860052.APCGeneralCollection Path: UPS.APC860052.APCForceShutdown Path: UPS.APCDelayBeforeShutdown.PowerConverter Path: UPS.APCDelayBeforeShutdown.PercentLoad Path: UPS.ff860024.ff860001 Path: UPS.ff860024.ff860023 Path: UPS.ff860024.ff860026 Path: UPS.ff860025 Path: UPS.iProduct Path: UPS.APC_UPS_FirmwareRevision Path: UPS.iSerialNumber Path: UPS.iManufacturer Path: UPS.ManufacturerDate.PresentStatus Path: UPS.ManufacturerDate.Charging Path: UPS.ManufacturerDate.Discharging Path:...
2006 Feb 08
2
2.0.3-pre2: Spurious UPS UPS@localhost battery is
Peter Selinger wrote: > Hm. I need more information, as NUT seems to garble the values even > before I can see them. I am not so worried about the date and > temperatures (although, strangely, the battery replacement date > appears to be Sept 25, 2001, which makes no sense). But the voltage is > definitely important. > > [...] > Thanks Peter - I'll send the new
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...ffset: 0, Size: 8, Value: 26 > 0.079478 Path: UPS.PowerConverter.ff860024, Type: Feature, ReportID: 0x51, Offset: 0, Size: 8, Value: 226 > 0.080454 Path: UPS.PowerConverter.ConfigActivePower, Type: Feature, ReportID: 0x52, Offset: 0, Size: 16, Value: 330 > 0.081163 Path: UPS.ff860001.ff860023, Type: Feature, ReportID: 0x60, Offset: 0, Size: 16, Value: 0 > 0.081788 Path: UPS.ff860001.ff860026, Type: Feature, ReportID: 0x61, Offset: 0, Size: 8, Value: 138 > 0.082900 Path: UPS.ff860001.ff860025, Type: Feature, ReportID: 0x62, Offset: 0, Size: 32, Value: 5.0463e+07...
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...Size: 8, Value: 26 >> 0.079478 Path: UPS.PowerConverter.ff860024, Type: Feature, ReportID: 0x51, Offset: 0, Size: 8, Value: 226 >> 0.080454 Path: UPS.PowerConverter.ConfigActivePower, Type: Feature, ReportID: 0x52, Offset: 0, Size: 16, Value: 330 >> 0.081163 Path: UPS.ff860001.ff860023, Type: Feature, ReportID: 0x60, Offset: 0, Size: 16, Value: 0 >> 0.081788 Path: UPS.ff860001.ff860026, Type: Feature, ReportID: 0x61, Offset: 0, Size: 8, Value: 138 >> 0.082900 Path: UPS.ff860001.ff860025, Type: Feature, ReportID: 0x62, Offset: 0, Size: 32, Value: 5.046...
2012 Apr 09
2
libusb_get_report: Unknown error
...s.ff860080, Type: Input, ReportID: 0x33, Offset: 12, Size: 1, Value: 0 1.172754 Report[buf]: (3 bytes) => 33 8c 00 1.172759 Path: UPS.PresentStatus.ff860080, Type: Feature, ReportID: 0x33, Offset: 12, Size: 1, Value: 0 1.178481 Report[get]: (3 bytes) => 60 00 00 1.178504 Path: UPS.ff860001.ff860023, Type: Feature, ReportID: 0x60, Offset: 0, Size: 16, Value: 0 1.184508 Report[get]: (2 bytes) => 61 89 1.184536 Path: UPS.ff860001.ff860026, Type: Feature, ReportID: 0x61, Offset: 0, Size: 8, Value: 137 1.190486 Report[get]: (5 bytes) => 62 00 01 02 03 1.190511 Path: UPS....
2020 Sep 03
2
UPS reboots with APC UPS
...eportID: 0x50, Offset: 0, Size: 8, Value: 51 0.734407 Path: UPS.PowerConverter.ff860024, Type: Feature, ReportID: 0x51, Offset: 0, Size: 8, Value: 126 0.737374 Path: UPS.PowerConverter.ConfigActivePower, Type: Feature, ReportID: 0x52, Offset: 0, Size: 16, Value: 700 0.742362 Path: UPS.ff860001.ff860023, Type: Feature, ReportID: 0x60, Offset: 0, Size: 16, Value: 0 0.746395 Path: UPS.ff860001.ff860026, Type: Feature, ReportID: 0x61, Offset: 0, Size: 8, Value: 154 0.750367 Path: UPS.ff860001.ff860025, Type: Feature, ReportID: 0x62, Offset: 0, Size: 32, Value: 0 0.753390 Path:...
2005 Jul 22
1
Another HID USB UPS
...oltageTransfer Path: UPS.ff860018.HighVoltageTransfer Path: UPS.ff860018.ff860024 Path: UPS.ff860018.ff860061 Path: UPS.APC860052.APCGeneralCollection Path: UPS.APC860052.APCForceShutdown Path: UPS.APCDelayBeforeShutdown.PowerConverter Path: UPS.APCDelayBeforeShutdown.PercentLoad Path: UPS.ff860024.ff860001 Path: UPS.ff860024.ff860023 Path: UPS.ff860024.ff860026 Path: UPS.ff860025 Path: UPS.iProduct Path: UPS.APC_UPS_FirmwareRevision Path: UPS.iSerialNumber Path: UPS.iManufacturer Path: UPS.ManufacturerDate.PresentStatus Path: UPS.ManufacturerDate.Charging Path: UPS.ManufacturerDate.Discharging Path:...
2005 Aug 02
0
newhidups for APC Back-UPS ES 650
...oltageTransfer Path: UPS.ff860018.HighVoltageTransfer Path: UPS.ff860018.ff860024 Path: UPS.ff860018.ff860061 Path: UPS.APC860052.APCGeneralCollection Path: UPS.APC860052.APCForceShutdown Path: UPS.APCDelayBeforeShutdown.PowerConverter Path: UPS.APCDelayBeforeShutdown.PercentLoad Path: UPS.ff860024.ff860001 Path: UPS.ff860024.ff860023 Path: UPS.ff860024.ff860026 Path: UPS.ff860025 Path: UPS.iProduct Path: UPS.APC_UPS_FirmwareRevision Path: UPS.iSerialNumber Path: UPS.iManufacturer Path: UPS.ManufacturerDate.PresentStatus Path: UPS.ManufacturerDate.Charging Path: UPS.ManufacturerDate.Discharging Path:...