UPS BZ1500PBI-BR (Microsol - Brazil) Compatibility.
...g to set this UPS up on a Synology NAS DS218+ which uses
NUT, and even though they are using NUT, they don't have all drivers
available as NUT has them at NUT's website.
Please see that below:
root at DSAltaCloud:/usr/syno/etc/ups# upsdrvctl start
Network UPS Tools - UPS driver controller
DSM6-2-1-newmodel-repack-23796-180722
Network UPS Tools - Generic HID driver 0.38
(DSM6-2-1-newmodel-repack-23796-180722)
USB communication driver 0.32
This APC device (051d:c812) is not (or perhaps not yet) supported
by usbhid-ups. Please make sure you have an up-to-date version of NUT. If
this does no...
2017 Sep 19
2
Bug or feature? polling frequency = (pollfreq + pollinterval)
Hi,
Context of my question:
* OS name and version,
Synology's distributed Linux: Linux DS 3.10.102 #15152 SMP Fri Sep 1
11:15:03 CST 2017 x86_64 GNU/Linux
* exact NUT version,
Tricky... the installed tools display:
$ /usr/sbin/upsd -V
Network UPS Tools upsd DSM6-1-15114-170518
while the one I've compiled, and its not running, displays:
$ /opt/sbin/upsd -V
Network UPS Tools upsd 2.7.4
My guess is that they are the same version (Synology keeps it updated).
Also...
driver.version: DSM6-1-15114-170518
driver.version.data: MGE HID 1.33
* NUT installa...
2018 Sep 26
1
[HCL] Cyber Power Systems CP600LCD supported by usbhid-ups
...y.runtime: 2220
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 13.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS CP600
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 5
driver.parameter.port: auto
driver.version: DSM6-2-23656-180331
driver.version.data: CyberPower HID 0.3
driver.version.internal: 0.38
input.transfer.high: 140
input.transfer.low: 100
input.voltage: 120.0
input.voltage.nominal: 120
output.voltage: 120.0
ups.beeper.status: enabled
ups.delay.shutdown: 20
ups.delay.start: 30
ups.load: 22
ups.mfr: CPS...
2020 Aug 06
0
Synology NAS is shutting down Ubuntu servers after very brief power outage (fwd)
...al: 12.0
> device.mfr: American Power Conversion
> device.model: Back-UPS NS 650M1
> device.serial: 4B1650P02109
> device.type: ups
> driver.name: usbhid-ups
> driver.parameter.pollfreq: 30
> driver.parameter.pollinterval: 5
> driver.parameter.port: auto
> driver.version: DSM6-2-25364-191230
> driver.version.data: APC HID 0.95
> driver.version.internal: 0.38
> input.sensitivity: medium
> input.transfer.high: 139
> input.transfer.low: 92
> input.transfer.reason: input voltage out of range
> input.voltage: 121.0
> input.voltage.nominal: 120
> ups...
2020 Aug 05
2
Synology NAS is shutting down Ubuntu servers after very brief power outage (fwd)
> grep nut /etc/passwd
nut:x:129:134::/var/lib/nut:/usr/sbin/nologin
> In your manual test do you restore utility power after 3-5 seconds?
Yes, I have tried that. I have also tried less than one second. I’ve tried for 1-2 minutes, for 3-5 minutes, I’ve tried just about every length of time and all appears Ok when I manually test.
--
Todd Benivegna // todd at benivegna.com
On Aug 5,
2018 Mar 10
2
UPS CYBERPOWER CP1300EPFCLCD MISSING FROMCOMPATIBILITY LIST
...ttery.type: PbAcid
battery.voltage: 16.0
battery.voltage.nominal: 24
device.mfr: CPS
device.model: CP1300EPFCLCD
device.serial: CTNGO2000027
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 5
driver.parameter.port: auto
driver.version: DSM6-1-15205-171017-1-gf424baa
driver.version.data: CyberPower HID 0.3
driver.version.internal: 0.38
input.transfer.high: 260
input.transfer.low: 170
input.voltage: 243.0
input.voltage.nominal: 230
output.voltage: 260.0
ups.beeper.status: enabled
ups.delay.shutdown: 20
ups.delay.start: 30
ups...