search for: disconnect_conf

Displaying 10 results from an estimated 10 matches for "disconnect_conf".

2005 Jul 15
2
Strange problem with SIP and CAPI
...NECT_B3_IND ID=003 #0x8145 LEN=0015 Controller/PLCI/NCCI = 0x10101 Reason_B3 = 0x0 NCPI = default == DISCONNECT_B3_IND NCCI=0x10101 > sent DISCONNECT_B3_RESP NCCI=0x10101 > sent DISCONNECT_REQ PLCI=0x101 -- DISCONNECT_CONF ID=003 #0x0863 LEN=0014 Controller/PLCI/NCCI = 0x101 Info = 0x0 -- DISCONNECT_CONF ID=003 #0x0863 LEN=0014 Controller/PLCI/NCCI = 0x101 Info = 0x0 -- DISCONNECT_IND ID=003 #0x8146 LEN=0014 Controller/PLC...
2004 Jun 28
4
Chan_Capi Down
...omsn = @89930 == found capi with omsn = 89930 == CAPI Call CAPI[contr1/89930]/3 == CAPI Call CAPI[contr1/89930]/3 -- CONNECT_CONF ID=003 #0x000e LEN=0014 Controller/PLCI/NCCI = 0x101 Info = 0x0 == received CONNECT_CONF PLCI = 0x101 INFO = 0 -- DISCONNECT_CONF ID=003 #0x000f LEN=0014 Controller/PLCI/NCCI = 0xffffffff Info = 0x2002 -- DISCONNECT_IND ID=003 #0x0003 LEN=0014 Controller/PLCI/NCCI = 0x101 Reason = 0x3302 == DISCONNECT_IND PLCI=0x101 REASON=0x3302 ==...
2004 Jan 20
0
chan_capi capiECT
...x353 == DISCONNECT_IND PLCI=0x101 REASON=0x3301 == DISCONNECT_IND PLCI=0x201 REASON=0x3301 Jan 20 10:06:35 NOTICE[8201]: app_capiECT.c:150 capiECT_exec: sent DISCONNECT_REQ PLCI=0x201 == Spawn extension (remote, s, 5) exited non-zero on 'CAPI[contr1/30]/0' -- CAPI Hangingup -- DISCONNECT_CONF ID=004 #0x0006 LEN=0014 Controller/PLCI/NCCI = 0x201 Info = 0x2002 Jan 20 10:06:35 NOTICE[2051]: chan_capi.c:1142 find_pipe: PLCI doesnt match last pipe (PLCI = 0x201) Jan 20 10:06:35 NOTICE[2051]: chan_capi.c:1255 pipe_msg: DISCONNECT_CONF ID=004 #0x0006...
2004 May 06
0
AVM Fritz doesn't pick up call or make calls
...ID=002 #0x0004 LEN=0014 Controller/PLCI/NCCI = 0x101 Info = 0x0 == received CONNECT_CONF PLCI = 0x101 INFO = 0 Using an IAX soft phone. The softphone just rings and rings. After hanging up I get. -- CAPI Hangingup > activehangingup -- DISCONNECT_CONF ID=002 #0x0005 LEN=0014 Controller/PLCI/NCCI = 0x101 Info = 0x0 My question is - does this look like a software or a hardware error? I'd just like to mention capi4-hylafax sendfax app just hangs. I believe with the NT1 i might need a terminating resis...
2004 Jan 20
4
CAPI: Early-B3 working with AVM-B1?
...ISCONNECT_B3_REQ NCCI=0x10101 -- DISCONNECT_B3_CONF ID=001 #0x001a LEN=0014 Controller/PLCI/NCCI = 0x10101 Info = 0x0 == DISCONNECT_B3_IND NCCI=0x10101 > sent DISCONNECT_B3_RESP NCCI=0x10101 > sent DISCONNECT_REQ PLCI=0x101 -- DISCONNECT_CONF ID=001 #0x001b LEN=0014 Controller/PLCI/NCCI = 0x101 Info = 0x0 == DISCONNECT_IND PLCI=0x101 REASON=0x3495 > sent DISCONNECT_RESP PLCI=0x101 -- removed pipe for PLCI = 0x101 ------- Hardware is a AVM-B1 (active BRI card) What am I doing wr...
2004 Nov 27
2
capi question
hi, I've been running a pure sip asterisk box for a while now with no problems, and i've recently added an isdn2e line from bt in the uk. everything is hooked up and i've got it ringing my sip extensions, but the logs don't quite look perfect and i can't see any description of what i should consider to be normal behaviour. would someone be able to look this over and tell me
2005 Sep 19
0
Call dropped 100% of time when incoming IAX routed to outgoing CAPI
...ult Keypadfacility = default Useruserdata = default Facilitydataarray = default SendingComplete = default == Spawn extension (iax-net-in, 4050, 1) exited non-zero on 'IAX2/iax-olcs-brisbane at iax-olcs-brisbane/2' DISCONNECT_CONF ID=002 #0x3f56 LEN=0014 Controller/PLCI/NCCI = 0x101 Info = 0x0 -- Hungup 'IAX2/iax-olcs-brisbane at iax-olcs-brisbane/2' INFO_IND ID=002 #0x575a LEN=0017 Controller/PLCI/NCCI = 0x101 InfoNumber = 0x8 InfoE...
2007 Jul 24
0
Diva Server BRI hangs up after about 25 seconds
...Keypadfacility = default Useruserdata = default Facilitydataarray = default SendingComplete = default > CAPI devicestate requested for EICONISDN/093759999 > CAPI devicestate requested for EICONISDN/093759999 DISCONNECT_CONF ID=001 #0x04e4 LEN=0014 Controller/PLCI/NCCI = 0x201 Info = 0x0 INFO_IND ID=001 #0x04f2 LEN=0015 Controller/PLCI/NCCI = 0x201 InfoNumber = 0x805a InfoElement = default INFO_RESP ID=001 #0x04f2 LEN=...
2007 Sep 13
1
fax machine detection for outgoing call on DIVA card
...Reason_B3 = 0x0 NCPI = default DISCONNECT_B3_RESP ID=002 #0x094a LEN=0012 Controller/PLCI/NCCI = 0x120302 DISCONNECT_REQ ID=002 #0x0887 LEN=0013 Controller/PLCI/NCCI = 0x302 AdditionalInfo = default DISCONNECT_CONF ID=002 #0x0887 LEN=0014 Controller/PLCI/NCCI = 0x302 Info = 0x0 INFO_IND ID=002 #0x094b LEN=0037 Controller/PLCI/NCCI = 0x302 InfoNumber = 0x1c InfoElement = <91 a1 13 02 02 02 a9 02 01 22>0&l...
2007 Mar 18
1
Choppy sound with chan_capi + Fritz Card USB
...02 #0x0194 LEN=0018 Controller/PLCI/NCCI = 0x101 AdditionalInfo BChannelinformation = default Keypadfacility = default Useruserdata = default Facilitydataarray = default SendingComplete = default DISCONNECT_CONF ID=002 #0x0194 LEN=0014 Controller/PLCI/NCCI = 0x101 Info = 0x0 DISCONNECT_IND ID=002 #0x0197 LEN=0014 Controller/PLCI/NCCI = 0x101 Reason = 0x3490 DISCONNECT_RESP ID=002 #0x0197 LEN=0012 Controller/PLCI/NCCI...