battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
2017 Apr 03
1
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
...to my copy, it does a -wall (warn all) by default, and it looks
> like REPLBATT is one such message, and the default time for a repeat is
> 12 hours. The -wall type message shows on every open terminal on the
> system's network, so someone should see it. From the upsmon.conf file:
[cuuuut]
> Possible values for type:
>
> ONLINE
> UPS is back online
>
> ONBATT
> UPS is on battery
>
> LOWBATT
> UPS is on battery and has a low battery (is critical)
>
>...
2011 Sep 02
2
NUT 2.6.1+ Windows 2008 R2 - NOTIFYCMD not being called
Hi All,
I'm using a recent post 2.6.1 build provided by Fred (executables have modified date of 9th August)
I have configured upsmon.conf with :-
NOTIFYCMD C:\NUT\etc\NotifyCmd.bat
and :-
NOTIFYFLAG ONLINE SYSLOG+EXEC
NOTIFYFLAG ONBATT SYSLOG+EXEC
NOTIFYFLAG LOWBATT SYSLOG+EXEC
NOTIFYFLAG FSD SYSLOG+EXEC
NOTIFYFLAG COMMOK SYSLOG+EXEC
NOTIFYFLAG COMMBAD SYSLOG+EXEC
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
2017 Apr 03
3
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
On Mon, 3 Apr 2017, Gene Heskett wrote:
>>
> Nut, IIRC, can do a periodic battery test by putting it offline, using
> the battery, for a predetermined length of time, weekly, monthly etc,
We definitely don't want that in this instance either! (Unless it is a
dual PS server.) We want the ALARM that the nut driver is generating,
and upsd is passing on - to be acted on in some