Can't get CyberPower UPS to work with Raspberry Pi 4
...the second command: Init SSL without certificate database battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 20 battery.mfr.date: CPS battery.runtime: 15690 battery.runtime.low: 300 battery.type: PbAcid battery.voltage: 24.0 battery.voltage.nominal: 24 device.mfr: CPS device.model: CST135XLU device.serial: CR7EO2003120 device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 5 driver.parameter.port: auto driver.parameter.synchronous: no driver.version: 2.7.4 driver.version.data: CyberPower HID 0.4 driver.version.internal: 0.41 input.voltage:...
2020 Oct 26
0
Can't get CyberPower UPS to work with Raspberry Pi 4
...tery.type: PbAcid > battery.voltage: 24.0 > battery.voltage.nominal: 24 I don't have the citation handy, but I think another user reported that the battery.voltage returned by the UPS is a constant 24.0 V, regardless of the actual battery voltage. > device.mfr: CPS > device.model: CST135XLU > device.serial: CR7EO2003120 > device.type: ups > driver.name: usbhid-ups > driver.parameter.pollfreq: 30 > driver.parameter.pollinterval: 5 > driver.parameter.port: auto > driver.parameter.synchronous: no > driver.version: 2.7.4 > driver.version.data: CyberPower HID 0.4...
2020 Oct 21
1
Can't get CyberPower UPS to work with Raspberry Pi 4
...evice name and related information (manufacturing date, web pointers, …) lsusb reports: ID 0764:0501 Cyber Power System, Inc. CP1500 AVR UPS Actual model number is CST135LXU according to the device's labeling. Here's the web page: https://www.cyberpowersystems.com/product/ups/battery-backup/cst135xlu/ complete problem description, with any relevant traces, like system log excerpts, and driver debug output. You can obtain the latter using the following command, as root and after having stopped NUT: /path/to/driver -DD -a <upsname> After installing and rebooting, running ups-info returns:...
2019 Mar 30
2
upssched Not Running
2020 Oct 26
2
Can't get CyberPower UPS to work with Raspberry Pi 4
...: 24.0 > > battery.voltage.nominal: 24 > > I don't have the citation handy, but I think another user reported > that the battery.voltage returned by the UPS is a constant 24.0 V, > regardless of the actual battery voltage. > > > device.mfr: CPS > > device.model: CST135XLU > > device.serial: CR7EO2003120 > > device.type: ups > > driver.name: usbhid-ups > > driver.parameter.pollfreq: 30 > > driver.parameter.pollinterval: 5 > > driver.parameter.port: auto > > driver.parameter.synchronous: no > > driver.version: 2.7.4 >...
2020 Oct 23
2
Nut-upsuser Digest, Vol 184, Issue 8
...16 - Bus: 002 0.004119 - Device release number: 0104 0.004180 Trying to match device 0.004295 Device does not match - skipping 0.004395 Checking device (0764/0501) (001/003) 0.010965 - VendorID: 0764 0.011077 - ProductID: 0501 0.011162 - Manufacturer: CPS 0.011247 - Product: CST135XLU 0.011330 - Serial Number: CR7EO2003120 0.011414 - Bus: 001 0.011498 - Device release number: 0200 0.011584 Trying to match device 0.011678 Device matches 0.011777 failed to claim USB device: could not claim interface 0: Device or resource busy 0.012115 detached kernel driver fr...
2019 Apr 03
2
upssched Not Running
...grep -Ev "^(#|\s*$)" /etc/nut/nut.conf > MODE=standalone > > ups.conf: > $ grep -Ev "^(#|\s*$)" /etc/nut/ups.conf > [myups1] >     driver   = usbhid-ups >     port     = auto >     vendorid = 0764 >     desc     = "CyberPower 1350VA/CP1500AVR/CST135XLU on rockenfield" >     pollinterval = 10 >     ignorelb >     override.battery.charge.low = 80 >     override.battery.charge.warning = 90 >     override.battery.runtime.low = 900 > > upsd.conf: > $ grep -Ev "^(#|\s*$)" /etc/nut/upsd.conf > LISTEN 192.1...
2019 Apr 03
0
upssched Not Running
2019 May 25
2
Low Battery False Alarms