Displaying 7 results from an estimated 7 matches for "cp825avr".
Did you mean:
cp685avr
2016 May 07
2
cyberpower ups need to manully turn on the switch
Hi
I have CP825AVR-G UPS. sometimes the UPS is shutdown due to whatever
reason.
But the annoying thing is even if the electrical power is back, that UPS
will continue to beep, and I have to manually turn on the switch button in
order for it to supply the load/power.
I am wondering if there is any setting in the UP...
2013 Nov 22
0
[HCL] CyberPower LE825G supported by Cyber Power Systems ups 2 685AVR USB (usbhid-ups) driver
...m successfully shutdown as expected.
upsc output:
upsc ups
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1110
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 8.7
battery.voltage.nominal: 12
device.mfr: CPS
device.model: CP825AVR-G
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/ugen2.3
driver.version: 2.6.5
driver.version.data: CyberPower HID 0.3
driver.version.internal: 0.37
input.transfer.high: 140
input.transfer.low: 90
input.voltage: 12...
2016 May 07
0
cyberpower ups need to manully turn on the switch
On Sat, 7 May 2016, Min Wang wrote:
> Hi? I have?CP825AVR-G UPS. ?sometimes the UPS is shutdown due to
> whatever reason.?
>
> But the annoying thing is even if the electrical power is back, that UPS
> will continue to beep, and I have to manually turn on the switch button
> in order for it to supply the load/power.
>
> I am wond...
2014 Aug 11
1
Cyberpower Value1200E might not need 0.667 battery scaling
...}
>
> /* USB IDs device table */
> static usb_device_id_t cps_usb_device_table[] = {
> - /* 900AVR/BC900D, CP1200AVR/BC1200D */
> + /* 900AVR/BC900D */
> { USB_DEVICE(CPS_VENDORID, 0x0005), NULL },
> - /* Dynex DX-800U? */
> + /* Dynex DX-800U?, CP1200AVR/BC1200D, CP825AVR-G, CP1000AVRLCD, CP1000PFCLCD, CP1500C, CP550HG, etc. */
> { USB_DEVICE(CPS_VENDORID, 0x0501), &cps_battery_scale },
> /* OR2200LCDRM2U, OR700LCDRM1U, PR6000LCDRTXL5U */
> { USB_DEVICE(CPS_VENDORID, 0x0601), NULL },
> @@ -59,12 +66,48 @@ static usb_device_id_t cps_usb_devic...
2014 Aug 09
0
Cyberpower Value1200E might not need 0.667 battery scaling
On Aug 8, 2014, at 9:15 AM, Charles Lepple <clepple at gmail.com> wrote:
> On Aug 7, 2014, at 10:52 PM, Charles Lepple <clepple at gmail.com> wrote:
>
>> On Aug 7, 2014, at 10:18 PM, Matthew Stapleton <matthew4196 at gmail.com> wrote:
>>
>>> I just got a Cyberpower SOHO Value 1200 ELCD UPS and even with nut 2.7.2, it appears to report battery voltage
2016 May 08
2
cyberpower ups need to manully turn on the switch
...mmand to the UPS to turn it
off" may cause that issue?
I saw:
ups.delay.shutdown: 20
ups.delay.start: 30
is it something related?
thanks
min
On Sat, May 7, 2016 at 3:44 PM, Roger Price <roger at rogerprice.org> wrote:
> On Sat, 7 May 2016, Min Wang wrote:
>
> Hi I have CP825AVR-G UPS. sometimes the UPS is shutdown due to whatever
>> reason.
>>
>> But the annoying thing is even if the electrical power is back, that UPS
>> will continue to beep, and I have to manually turn on the switch button in
>> order for it to supply the load/power.
>&...
2014 Aug 08
2
Cyberpower Value1200E might not need 0.667 battery scaling
On Aug 7, 2014, at 10:52 PM, Charles Lepple <clepple at gmail.com> wrote:
> On Aug 7, 2014, at 10:18 PM, Matthew Stapleton <matthew4196 at gmail.com> wrote:
>
>> I just got a Cyberpower SOHO Value 1200 ELCD UPS and even with nut 2.7.2, it appears to report battery voltage too low due to the battery scaling function (In drivers/cps-hid.c). Even though the ups has usb id: