2004 Apr 08
0
(no subject)
Sub: INTRODUCTION FOR SUPPLY OF SPECIAL CABLES
We have pleasure in introducing ourselves as manufacturer's of specialised cables for over two decades catering to the needs of the Fertilizer, Chemical, Petrochemical, Oil & Gas, Steel, Power, Cement, Ceramic, Glass, Paper, Sugar and other industries. The following are some of the cables made by us:
ANY CABLE, ANY TIME, ANY QUANTITY
2006 Apr 24
1
Shielding of T1/E1 cables WAS RE: Pinouts for T1/E1 crossover cable WAS "RE: what cable to connect a legacy PBX to a TE410P ?"
I was once told by a lineman that the cables they use didn't have that
many twists in them because it wasn't needed, and that the extra twists
would effectively use more cable and thus cost and weigh more than
triple what they do now. He told me that with the number of twists in
the Cat 5 cable it would cancel out any interference, but he also stated
that the effective length was
2006 Apr 22
4
Pinouts for T1/E1 crossover cable WAS "RE: what cable to connect a legacy PBX to a TE410P ?"
Can't anyone stop self-promotion and tell the poor guy what he needs.
A T1/E1 X-over cable using an RJ-45 (8-cond.) is pinned out as follows:
1 - 4
2 - 5
3 - NU
4 - 1
5 - 2
6 - NU
7 - NU
8 - NU
NU = Not Used
I have not in my experience seen any problems with using a Good Quality
Cat5 vs. Cat 3 (telco standard) cable for X-connects. YMMV, but you
should be fine. As far as the shielding
2006 Mar 05
6
Polycom 501 power over ethernet
When I bought two Polycom 501 SIP phones, I naively thought they were
Power-over-Ethernet (IEEE 802.3af) because they were "powered over
ethernet." Silly me.
Polycom must have some odd voltage or funny way of injecting the
power, because the POE switch I bought for them (Netgear F@510P)
won't power them, though if I use the Polycom-supplied AC adapter and
ethernet power
2007 Mar 18
6
T1 cable for Digium T1/E1 Cards
Is there any technical difference between a T1 cable and a cat5e patch
cable as far as using them with Digium T1/E1 cards? Can PRI circuits
terminating at a smart jack connect successfully to Digium cards using
straight through CAT5e cables? If so, are they using all of the pins in
the cable?
Thanks in advance
2009 Aug 03
1
SmartUPS-600 problem with 940-0024C cable
...hout cable option
desc "apc test"
</snip>
# /lib/nut/apcsmart -a myups -D
Network UPS Tools - APC Smart protocol driver 2.00 (2.4.1)
APC command table version 2.0
debug level is '1'
# some delay here..
Unable to detect an APC Smart protocol UPS on port /dev/ttyS0
Check the cabling, port name or model name and try again
So as I said above, sending through My own app or minicom works fine but I'm
not able to receive anything.
I checked all wires again and again, connections is ok, pins are ok.
Is there anybody who has the same UPS (mine is from 1990) and who is able to...
2005 Aug 08
1
Here are CORRECT APC cable diagrams
+-----------------------------------------------------------------+
| |
| Black APC 940-0024C Smart Signalling UPS Cable Wiring Diagram |
| This information is verified and tested to be 100% correct. |
| |
2006 Apr 24
1
Re: Shielding of T1/E1 cables WAS RE: PinoutsforT1/E1 crossover
> Close. 10/100mbps Ethernet uses wires 1,2,3,6 but that is pair 2 & 3.
> Pair
> one is the pair up the dead center (pins 4&5), pair 2 is pins 1&2,
pair 3
> is
> 3&6 and pair 4 is 7&8. A T1 uses pairs 1&2, which is why you can't
use a
> regular crossover cable for a T1 crossover, but you can use a regular
> ethernet patch cable as a T1 patch
2006 Apr 24
1
Pinouts for T1/E1 crossover cable WAS "RE: what cable to connect a legacy PBX to a TE410P ?"
At Sangoma we do quite a lot of back-to back T1 and E1
connections. T1 is not a very fussy connection, as the baud
rate is only about 750 kbps.
In our experience, for error free communications you can use
the following rules of thumb:
Up to 50 ft: Flat patch cable
Up to 500 ft: Ordinary twisted telephone cable Cat 5 may be
overkill unless you are going hundreds of feet.
David Yat Sin
2017 Feb 03
2
Spotty internet connection
On 2/3/2017 4:38 AM, Styma, Robert (Nokia - US) wrote:
> Another thing to check is the wiring to the house. If this is a cable company, it is likely that the cable to the cable modem splits off to the TV(s). Make sure there are not any unterminated co-ax cable which used to go to a TV. Make sure the cable outside the house is not damaged. The cable company can test for bad cable at your
2007 Oct 12
2
MGE Ellipse USB cable config ?
Hi everyone,
This is not directly NUT related, but i don't know where else I can
still ask this.
I have been using a pretty decent 2nd hand MGE ellipse premium 1200VA
for a while now at home. http://www.mgeups.com/download/doc_intl/
small/premium/389uk.pdf
It's been working very well for me on linux, but my linux server has
recently passed away and now I only have Macs left.
2010 Dec 25
4
2 Ethernet cabling question
Two questions that was not always clear for me [sorry for posting to this list :\]:
##############################################################################################
Q1) when cabling, is the color order important? like:
straight cabling:
A side: white-orange, orange, white-green, blue, white-blue, green, white-brown, brown
B side: white-orange, orange, white-green, blue, white-blue, green, white-brown, brown
could be eg.: like this??
A side: white-orange, brown, white-blue, g...
2004 Dec 16
3
Has anyone connected to 7960 with console cable for setup?
I have a Cisco 7960 phone. I cannot seem to use the settings button to get
into the phone to change the TFTP server. I've set up a DHCP Server, TFTP
Server with the same address, and the phone requests the address of 0.0.0.0,
the server offers the address of 192.168.2.2, but the phone seems not to
take it.
I have no action on the TFTP side.
So, since I can't seem to server the phone
2007 May 10
1
Polycom power over ethernet (PoE) cables for 500/501, 600/601 and 650 sets
Hi, folks:
I just took delivery of new PoE cables (PN 2200-11077-002) for our
Polycom phones here in the office.
I have the following to report, for the erudition of existing Polycom
users and those considering purchasing Polycom sets from the set of
models noted in the subject:
1. The cables do indeed work (hooray).
2. The cable has a module on it about a third of the way from a female
end.
2004 Oct 04
2
fxsmod cable length limit
Is there a cable length limit to use with a fxsmod (TDM400B) ?
I noticed that if I use a very long cable 148 feet, I can hear some
parasite : I hear the radio ! If I use a short cable, there is no
problem...
Thanks for help,
St?phane HENRY
2010 Nov 25
2
Timing cable usage necessity
Hello everyone.
I have a timing slips errors and I can't understand what source of the
problem is.
My installation has 2 digium cards: TE420 and TE220 cards in one server.
There are 3 spans (E1) to PSTN and 3 spans to internal PBS stations -
normal installation for transit communication.
Span configuration is:
span=1,1,0,ccs,hdb3 #TE420 - first port. To PSTN.
span=2,0,0,ccs,hdb3 #TE420 -
2007 Oct 26
4
Need T1 crossover cable?
I'm connecting a T1 PCI card to a Nortel Option 61 switch T1 card. My
Sangoma A102D shipped with 2 T1 cables - which I assume are straight
through. Do I need to make crossover cables for this scenario?
Thanks
-------------- next part --------------
An HTML attachment was scrubbed...
URL: http://lists.digium.com/pipermail/asterisk-users/attachments/20071026/9cea5e74/attachment.htm
2006 Apr 22
0
Pinouts for T1/E1 crossover cable WAS "RE: whatcable to connect a legacy PBX to a TE410P ?"
I for one think it is a great idea to buy a book with hard earned money and wait a few days to a week just to get an answer to a question that is freely available on the internet immediately.
Hard pressed to think of anything in the "book" that is not on with wiki with more up to date and useful information.
-----Original Message-----
From: Alexander Lopez
2007 Jan 12
1
Trouble connecting to apc smart 1500 via serial cable
...;
#cable = 940-0024C
# upsdrvctl start apc_chute
Network UPS Tools - UPS driver controller 2.0.4
Network UPS Tools (version 2.0.4) - APC Smart protocol driver
Driver version 1.99.8, command table version 2.0
Unable to detect an APC Smart protocol UPS on port /dev/ttyS0
Check the cabling, port name or model name and try again
Driver failed to start (exit status=1)
Just in case I tried that with ttyS1, but that reports an IO error, so I
guess that ttyS0 is the only serial connector on the machine. AFAIK the
serial cable works, or at least it was supposed to work, since
originally t...
2009 Nov 06
1
Can anyone give me some ideas?
I've got a big UPS from an italian manufacturer MSC elettronica which
should be megatec protocol based. They distribute it with Upsilon2000,
developed by Megatec, and with a cable listed on the megatec site:
http://www.megatec.com.tw/FAQ.htm
How do I know the M2505 cable is the one that should be used on my UPS
instead of M2502 cable?
UPS that use both these cables are TRUE RS232 UPS