Displaying 3 results from an estimated 3 matches for "bernaert".
Did you mean:
beernaert
2016 Jan 22
1
Not getting nut to work with Eaton 5115
Following the instructions a following site I can not get nut to work with
my UPS.
http://bernaerts.dyndns.org/linux/75-debian/335-debian-wheezy-install-monitor-eaton-ups
Hope that you can find out what is wrong by the provided info in the email
Best Regards,
Magnus Karlsson
# lsusb -s 001:005 -v
Bus 001 Device 005: ID 06da:0002 Phoenixtec Power Co., Ltd UPS
Device Descriptor:
bLength...
2015 Dec 02
0
Cannot access Patriot Pro II from new system
...wer_Patriot_Pro_750 at localhost 1 upsmon SOMESECRET master
MINSUPPLIES 1
SHUTDOWNCMD "/sbin/shutdown -h +0"
POLLFREQ 5
POLLFREQALERT 5
HOSTSYNC 15
DEADTIME 15
POWERDOWNFLAG /etc/killpower
RBWARNTIME 43200
NOCOMMWARNTIME 300
FINALDELAY 5
I am unsure since I found that another UPS
[http://bernaerts.dyndns.org/linux/75-debian/335-debian-wheezy-install-monitor-eaton-ups]
seems to feature a power threshold ...
> # upsc eaton at localhost
> battery.charge: 89
> *battery.charge.low: 20*
> ...
... but mine does not:
> # upsc Best_Power_Patriot_Pro_750
> Init SSL without certif...
2015 Nov 26
4
Cannot access Patriot Pro II from new system
Hi Charles,
thank you VERY MUCH for all your hints.
> If you have a jumper wire handy, you can connect the PC's TxD to RxD
I should have tried to connect from another computer in the first place.
Or access another device known to work from this computer. It turned out
that the shield I used to connect the mainboard connector to the PC case
expected another mainboard pin layout. So all I