Displaying 2 results from an estimated 2 matches for "ar2_nn_audio".
Did you mean:
ar1_nn_audio
2016 Jun 13
0
Opus application_mode==AUDIO, 20ms framing issue?
...n seen with +16000 +wb option)
5ms 10ms 20ms 40ms
ar1_NN_voip 4.314 4.493 4.488 4.488
ar2_NN_voip 4.346 4.442 4.436 4.474
ar3_NN_voip 3.993 4.375 4.414 4.390
ar1_NN_audio 4.292 4.485 -> 4.313 4.313
ar2_NN_audio 4.364 4.460 -> 4.350 4.350
ar3_NN_audio 3.924 4.327 -> 4.218 4.218
Note that this size/type of pesq test is insufficient to draw ANY conclusions.
However, it is useful for drawing attention to relative differences, that
might be interesting for HUMAN LISTENING.
So t...
2016 Jun 03
1
Opus application_mode==AUDIO, 20ms framing issue?
Hi Kevin,
Are you saying that the quality is good at 20 ms and bad at 10 ms, or
the reverse? Also, is this speech or music? What tool, what options? In
general, it helps a lot if you post the sample (input and output).
Cheers,
Jean-Marc
On 06/03/2016 12:48 PM, Kevin Connor wrote:
> Hi Opus list,
>
> I'm noticing a discontinuity in the quality between use of 10ms and
> 20ms